Brand: Endress+Hauser (E & H)
Endress+Hauser 8E5B Promass E 500 Remote Coriolis Flowmeter
Description
8E5B Endress+Hauser Promass E 500: a remote-mounted dual-tube Coriolis meter
The Endress+Hauser 8E5B is the product root of the Proline Promass E 500, a mid-range Coriolis flowmeter that separates the sensor from the transmitter. Technical Information TI01282D, issued in 2026, calls it a mid-range Coriolis flowmeter as remote version with up to 4 I/Os. You choose it when the process line is hot, vibrating or hard to reach but the operator still needs a readable display at eye level. The sensor carries a compact dual-tube measuring system, and a standard cable links it to the transmitter.
Because the measuring principle depends on tube oscillation, not on the physics of the fluid, the 8E5B reports mass flow, volume flow, density and temperature from one device. The datasheet names no in-run or out-run requirement and describes the meter as an alternative to conventional volumetric flowmeters for liquids and gases in standard applications. Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer, quotes the 8E5B against the order code you provide.
Key features of the 8E5B
- Medium temperature from -40 to +150 degC and process pressure up to 100 bar
- Remote transmitter with up to four freely configurable inputs and outputs
- Backlit display with touch control and WLAN access for commissioning
- Heartbeat Technology for built-in verification and monitoring on the application-package option
- CIP and SIP cleaning listed as internal cleaning methods
- Optional rupture disk with 10 to 15 bar trigger pressure for added safety
- Gas Fraction Handler available on HART, Modbus RS485, PROFINET and Ethernet-APL device versions
8E5B technical specifications
Every value below comes from TI01282D. Nominal diameters and full scale values are those printed for liquids; for gases the datasheet gives a formula that depends on gas density and speed of sound, so a gas line should be sized with the manufacturer applicator tool.
| Parameter | Value for 8E5B |
|---|---|
| Product root | 8E5B, Proline Promass E 500 Coriolis flowmeter (TI01282D) |
| Sensor design | Compact dual-tube sensor, remote transmitter, standard cable between the two |
| Nominal diameters | DN 8, 15, 25, 40, 50, 80 (3/8 to 3 inch) |
| Full scale, liquids DN 8 | 0 to 2 000 kg/h |
| Full scale, liquids DN 15 | 0 to 6 500 kg/h |
| Full scale, liquids DN 25 | 0 to 18 000 kg/h |
| Full scale, liquids DN 40 | 0 to 45 000 kg/h |
| Full scale, liquids DN 50 | 0 to 70 000 kg/h |
| Full scale, liquids DN 80 | 0 to 180 000 kg/h |
| Mass and volume flow accuracy, liquids | Plus/minus 0.15 % of reading; 0.10 % with calibration flow option A, B or C |
| Mass flow accuracy, gases | Plus/minus 0.50 % of reading |
| Density accuracy, liquids | Plus/minus 0.0005 g/cm3 under reference conditions; 0.002 g/cm3 standard calibration |
| Temperature accuracy | Plus/minus 0.5 degC plus 0.005 times T degC |
| Repeatability | 0.075 % of reading (0.05 % calibration option); gases 0.25 % up to Mach 0.2 |
| Medium temperature | -40 to +150 degC (-40 to +302 degF) |
| Process pressure | Up to 100 bar (1 450 psi) as stated on the cover page |
| Medium density | 0 to 5 000 kg/m3 |
| Ambient temperature | -40 to +60 degC; -50 to +60 degC with test certificate option JP |
| Protection class | IP66/67, Type 4X; IP69 with sensor option CM |
| Supply | DC 24 V plus/minus 20 % or AC 100 to 240 V, -15 to +10 %, 50/60 Hz |
| Power | Max. 10 W; switch-on current max. 36 A for less than 5 ms (NE 21) |
| Current output | 4 to 20 mA HART, load 250 to 700 ohm, resolution 0.38 microampere |
| Rupture disk option | 10 to 15 bar trigger pressure (sensor option CA) |
| Sensor weight, DN 8 to 80 | 4, 4, 6, 10, 15 and 29 kg with aluminum connection housing and PN 40 flanges |
Applications for the 8E5B
A remote Coriolis head suits terminals and refineries where the pipe rack is crowded. In Oman and the wider GCC, typical jobs include custody-type transfer checks on light products, dosing of additives in petrochemical blending, chemical injection skids and condensate lines. The temperature ceiling of 150 degC also fits heated fuel oil and glycol loops. In utilities, the 8E5B can meter boiler chemicals and heat transfer fluids without a straight-pipe run.
Manufacturing sites use it on solvent, resin and paint lines, where density output helps detect a product change. Water and desalination plants rely on the mass-flow output for antiscalant and caustic dosing. The Ex section of the datasheet lists versions with equipment protection level Ga/Gb, meaning Zone 0 in the measuring tube, for flammable-medium duty; the separate XA safety instructions hold the exact conditions.
How 8E5B differs from other Promass E variants
The E 100 and E 300 on the same sensor platform place the transmitter on the sensor, while the 8E5B moves it away on a cable; that is the one choice that decides whether the electronics see the process heat. Within the E 500 line the transmitter housing can be polycarbonate (1.4 kg), coated aluminum (2.4 kg for the digital version, 6.5 kg for the standard Proline 500) as listed in the weight section. Compared with Promass H 500 and I 500, which are single-tube sensors for corrosive or viscous service, the 8E5B stays with dual-tube geometry and tops out at DN 80 with a 150 degC medium limit.
Accuracy also separates the series. The 8E5B quotes 0.15 % of reading for liquids, improving to 0.10 % with a calibration option, while the H 500 and I 500 datasheets quote 0.10 %. Density performance of 0.0005 g/cm3 under reference conditions is shared across the family.
Selecting and ordering 8E5B
Start with line size and the full scale table: a DN 25 sensor covers 0 to 18 000 kg/h, a DN 50 covers 0 to 70 000 kg/h. Next choose the process connection; the datasheet lists EN 1092-1 flanges, ASME B16.5 and JIS B2220 flanges, NAMUR lengths per NE 132, DIN 11864-2 flanges, Tri-Clamp, DIN 11851, SMS 1145, ISO 2853 and DIN 11864-1 threads, plus 8-VCO-4 and 12-VCO-4 couplings. Then pick the connection housing (coated aluminum or stainless 1.4301, with optional 316L for hygienic corrosion resistance) and the power supply code D, E or I.
Choose the communication: HART current output is the baseline, with Modbus RS485, PROFINET, PROFINET over Ethernet-APL and Modbus TCP over Ethernet-APL also described in the document. Send the complete order code to Seven Star LLC so that sensor and transmitter match.
Installing and commissioning the 8E5B
Fit the sensor in a location where it stays full and where cavitation cannot occur; the datasheet recommends the lowest point of a vertical pipe or downstream of a pump. Keep the transmitter within cable reach, mounted on a pipe or wall using the stainless fixing parts. Use a dedicated circuit breaker of 2 A to 10 A, because the meter has no on-off switch. Observe the sinusoidal vibration limits of 2 to 8.4 Hz at 3.5 mm peak and 8.4 to 2 000 Hz at 1 g peak for the sensor.
Commission through the touch display or via WLAN, set the current output range (4 to 20 mA NAMUR, US or fixed) and run a zero-point check at no flow if the process allows. Outdoor transmitters should be shaded, since display readability falls outside -20 to +60 degC.
Maintenance notes for 8E5B
There are no moving parts, so upkeep is largely verification and keeping the sealing surfaces dry. Heartbeat Verification can be exported as a PDF report, which supports audit trails. Check cable glands and the device plug after pipe-rack vibration, and re-tighten after thermal cycling. If CIP or SIP is used, confirm that the chosen wetted material and gasket suit the cleaning agent.
8E5B quick answers
The 8E5B measures to 150 degC, supports DN 8 to 80, uses a remote transmitter and offers up to four I/Os. Its storage range is -50 to +80 degC and it tolerates 4 to 95 % relative humidity. Spares and sensors under related codes can be quoted together with this part number.
Documents and quotation
The attached datasheet is Technical Information TI01282D for the Promass E 500, covering dimensions, connections, approvals, accessories and ordering structure. Send an RFQ to Seven Star LLC with part number 8E5B, the order code, DN, connection type and quantity, and we will respond with availability and lead time.
Other Models in the Promass 500 Range
Seven Star LLC supplies models from the Promass 500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser 8I5B Promass I 500 Straight-Tube Coriolis Meter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 8E5B Promass E 500 Remote Coriolis Flowmeter | Ultrasonic Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser 8E5B Promass E 500 Remote Coriolis Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser 8E5B Promass E 500 Remote Coriolis
Answers from our engineering team on installation, compatibility and integration.
01Which nominal diameters does the 8E5B cover?
DN 8, 15, 25, 40, 50 and 80, equal to 3/8 to 3 inch, with full scale values from 2 000 to 180 000 kg/h for liquids.
02How hot can the medium be for the 8E5B?
The datasheet gives a medium temperature range of -40 to +150 degC, with process pressure up to 100 bar on the cover page.
03Is the 8E5B transmitter mounted on the sensor?
No. It is the remote version: the transmitter is installed separately and connected with a standard cable, with up to 4 I/Os.
04What accuracy does the 8E5B state for liquid mass flow?
Plus/minus 0.15 percent of reading, or 0.10 percent with calibration flow option A, B or C, per TI01282D.
05How do I request a quote for the 8E5B?
Send part number 8E5B with the full order code, nominal diameter, process connection and quantity to Seven Star LLC through an RFQ.