Endress+Hauser CM448R Liquiline Eight-Channel DIN-Rail Transmitter

Description

CM448R Liquiline: eight Memosens channels on a DIN rail

Endress+Hauser CM448R is the eight-channel member of the Liquiline R cabinet transmitter family. It mounts on a DIN rail per IEC 60715 or on a wall plate, takes up to eight Memosens digital sensors, and uses a modular design in which base module, sensor modules, analog and relay modules plug together. The operator display is a separate optional unit made of plastic or stainless steel that can be panel mounted at a distance with the 3 m display cable.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The technical information (TI01112C, edition 15.26-00) covers CM442R, CM444R and CM448R in a single document, so the values below are those that apply to CM448R or to the whole R family.

CM448R technical overview

Parameter Value
Channels Up to 8 Memosens sensors (6 with Ex-i module 2DS)
Optional inputs 2 x 0/4 to 20 mA passive; digital inputs 0 to 30 V
Current outputs 2, 4, 6 or 8 x 0/4 to 20 mA active, galvanically isolated; HART optional on output 1
Relays Alarm relay plus 2 or 4 optional relays
Fieldbuses HART, PROFIBUS DP, Modbus RS485 and TCP, EtherNet/IP, PROFINET, web server
Supply Via external DIN rail power unit (CM444R and CM448R)
Housing and protection PC-FR DIN rail housing, IP20; display IP66 on front panel
Weight About 0.95 kg fully configured; modules 0.06 kg each; display 0.56 kg plastic or 1.32 kg stainless
Storage temperature Minus 25 to 85 degrees C; 5 to 85 percent humidity
Surge protection Integrated per EN 61326-1; optional HAW562 on the DIN rail
Data storage SD card slot, industry-approved cards 1 to 32 GB
Example order code CM448R-**26A1*
Extras Heartbeat Verification and Monitoring by activation code

Software and diagnostics

Mathematics functions create calculated measured values, controllers and cleaning functions can be assigned to relays, and a standardised operating concept is shared across the Liquiline, sampler and analyzer platform. Memosens sensors arrive lab-calibrated and are hot plug and play. Heartbeat Verification lets the user prove correct operation of the device, and integration into FieldCare and W@M supports asset management.

How CM448R differs from CM442R and CM444R

CM442R carries two Memosens channels, runs on 100 to 230 V AC or 24 V AC/DC directly and weighs about 0.45 kg. CM444R has four Memosens inputs and CM448R has eight, both fed from an external DIN rail power unit and with a 0.95 kg fully configured weight. The part number CM448R is therefore the right one when many measuring points must be concentrated in a single cabinet, for example four pH points, two conductivity points and two oxygen points, with eight analog outputs to the control system.

Planning a CM448R cabinet

  • Allocate slots: base module, 2DS sensor modules, analog input and output modules and relay modules, in the order shown in the slot assignment table.
  • Size the external power unit, which weighs 0.27 to 0.42 kg depending on rating.
  • Choose the fieldbus module or activation code early, because upgrades follow a basic hardware rule in the datasheet.
  • Install a HAW562 surge protector on the DIN rail if supply lines are long.
  • Mount the display on the cabinet door with the template supplied, using the 3 m cable.

Communication and cybersecurity on CM448R

Several protocols can be combined with the same hardware. A 485DP module provides PROFIBUS DP, a 485MB module provides Modbus RS485 together with a web server (order number 71575178), and activation codes unlock Modbus TCP with web server, EtherNet/IP with web server, PROFINET with web server on the Base2 module, or the web server alone. Ethernet ports run at an automatic 100 Mbps with full-duplex detection. HART is available on current output 1 only, using FSK encoding of plus or minus 0.5 mA above the current signal, so the control system can read digital diagnostic data from the same pair.

The datasheet also dedicates a section to security and to maintainability, including SD card logging and firmware updates, so plants that run a cybersecurity policy can verify what the device exposes before it is connected to the network. Ask us for the order code of the existing Liquiline R unit so that modules, activation codes and the external power unit can be matched in one quotation.

Where CM448R is used in the GCC

Central control rooms at water and wastewater plants, desalination units and utility stations in Oman often collect many liquid analysis points. A single CM448R cabinet can read eight Memosens sensors and pass them to a PROFINET, Modbus or EtherNet/IP network, which cuts cabinet space and cabling compared with eight single-channel transmitters. The manufacturer lists food, life sciences, chemical and power industries in the same application list.

CM448R questions answered briefly

How many sensors can Endress+Hauser CM448R connect? Up to 8 Memosens digital sensors, or 6 when the Ex-i sensor communication module 2DS is used.

Which outputs does CM448R provide? Active 0/4 to 20 mA outputs in versions with 2, 4, 6 or 8 channels, optional HART on current output 1, relays, and digital I/O depending on modules.

What fieldbuses does CM448R support? HART, PROFIBUS DP, Modbus RS485, Modbus TCP, EtherNet/IP, PROFINET and an integrated web server, via activation codes or modules.

How is CM448R powered? The CM444R and CM448R are fed through an external DIN rail power unit rather than a mains-connected housing like the CM442R.

What is the weight and protection of CM448R? A fully configured CM448R weighs about 0.95 kg and the DIN rail device is IP20; the optional external display is IP66 at the front panel.

Documents and quotation

The datasheet for CM448R is attached. Send an RFQ with CM448R, the number of sensors, outputs, relays, fieldbus, display type and power unit, and the quantity.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser CM448R Liquiline Eight-Channel DIN-Rail Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CM448R Liquiline Eight-Channel

Answers from our engineering team on installation, compatibility and integration.

01How many sensors can Endress+Hauser CM448R connect?
Up to 8 Memosens digital sensors, or 6 when the Ex-i sensor communication module 2DS is used.
02Which outputs does CM448R provide?
Active 0/4 to 20 mA outputs in versions with 2, 4, 6 or 8 channels, optional HART on current output 1, relays, and digital I/O depending on modules.
03What fieldbuses does CM448R support?
HART, PROFIBUS DP, Modbus RS485, Modbus TCP, EtherNet/IP, PROFINET and an integrated web server, via activation codes or modules.
04How is CM448R powered?
The CM444R and CM448R are fed through an external DIN rail power unit rather than a mains-connected housing like the CM442R.
05What is the weight and protection of CM448R?
A fully configured CM448R weighs about 0.95 kg and the DIN rail device is IP20; the optional external display is IP66 at the front panel.