Endress+Hauser 5L4B Promag L 400 Electromagnetic Flowmeter

Description

5L4B Promag L 400: a lap-joint electromagnetic meter for water networks

Search interest in the Endress+Hauser 5L4B usually comes from utilities with an existing meter that has to be matched or replaced. The part number is the product root of the Proline Promag L 400, a weight-optimized electromagnetic sensor with a state-of-the-art transmitter for water and wastewater, according to TI01045D. The datasheet stresses up to 30 percent less sensor weight and a lap-joint flange concept that simplifies installation for sizes below DN 350.

The datasheet also contains a product generation index. It lists 5L4B with a release date of 1 July 2012, followed by the later root 5L4C, released on 1 November 2016. If you are replacing a meter, quote the number printed on the nameplate. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and we handle 5L4B and related roots by exact code.

Key features of the 5L4B

  • Nominal diameters from DN 25 to DN 2400, one of the widest spans in the electromagnetic range
  • Lap-joint flanges below DN 350 for easy alignment of bolt holes
  • Liner choices: hard rubber, polyurethane or PTFE
  • Transmitter in polycarbonate or coated aluminum, compact or wall-mounted remote
  • Display with touch control, integrated web server and WLAN access
  • Data logger for measured-value monitoring and Heartbeat Technology

5L4B specifications from TI01045D

Data are taken from the document dated 08.17. Where a value depends on liner or housing code, the code is shown so you can match it to a nameplate.

Parameter Value for 5L4B
Product root 5L4B, Proline Promag L 400 (TI01045D, edition 08.17)
Generation index 5L4B released 01.07.2012; later root 5L4C released 01.11.2016 with web server, logbook, Heartbeat hardware and WLAN changes
Nominal diameter range DN 25 to 2400 (1 to 90 inch)
Measuring principle Bidirectional electromagnetic
Typical measuring range v = 0.01 to 10 m/s (0.03 to 33 ft/s)
Minimum conductivity 5 microsiemens per cm for liquids in general
Example DN 25 range 9 to 300 dm3/min recommended; factory full scale 75 dm3/min
Volume flow accuracy Plus/minus 0.5 % of reading plus 1 mm/s; optional 0.2 % of reading plus 2 mm/s
Repeatability Max. 0.1 % of reading plus 0.5 mm/s
Liners and temperature limits Hard rubber 0 to +80 degC (DN 350 to 2400); polyurethane -20 to +50 degC (DN 25 to 1200); PTFE -20 to +90 degC (DN 25 to 300)
Electrodes Stainless steel 1.4435 (316L) or Alloy C22 (2.4602)
Measuring tube Stainless steel 1.4301/1.4306 (DN 25 to 300), 1.4301/1.4307 above
Process connections EN 1092-1 lap joint (DN up to 300) or fixed flange (DN 350 and up); ASME B16.5 Class 150; AWWA C207 Class D; AS 2129 Table E; AS 4087 PN 16
Flange finish Carbon steel lap joint flanges hot-dip galvanized
Supply DC 24 V plus/minus 25 %; AC 24 V plus/minus 25 %; AC 100 to 240 V, -15 to +10 %, 50/60 Hz
Power consumption Max. 30 VA / 8 W for HART and PROFIBUS DP versions
Current output 4 to 20 mA NAMUR, US or HART, or 0 to 20 mA; load 0 to 700 ohm; 0.5 microampere resolution
Pulse output accuracy Max. 50 ppm of reading
Ambient temperature, transmitter -40 to +60 degC
Protection class IP66/67 Type 4X standard; IP67 and IP68 (Type 6P) options for remote sensors
Compact transmitter weight 1.3 kg polycarbonate; 2.0 kg aluminum
Drinking water approvals ACS and KTW/W270 listed

Where 5L4B is used

The sizes up to DN 2400 serve water transmission mains, desalination product lines, reservoir outlets and irrigation headers. Wastewater plants fit it to influent and effluent pipes, and industrial sites meter cooling water and process water. Municipal water networks in the Gulf also use the meter for district metering where drinking-water approvals such as ACS and KTW/W270 are specified.

For buried or flood-prone chambers, the remote sensor can be ordered with IP68 protection; for DN up to 300 with stainless steel flanges only, as the datasheet specifies. Hot industrial water is not the target: the liner temperature limits restrict the meter to 90 degC at most.

How 5L4B differs from other Promag L variants

Against the later 5L4C root, the 5L4B has the earlier web server, logbook and Heartbeat hardware listed in the modification column of the generation index. The L 400 pairs its sensor with a full-featured transmitter that has a touch display and a data logger. Against Promag W 400 (5W4B), the L 400 is the weight-optimized sensor for water and wastewater that uses the lap-joint flange concept below DN 350.

Within the L 400 itself, the liner decides the temperature limit: PTFE to 90 degC for DN 25 to 300, polyurethane to 50 degC for DN 25 to 1200, hard rubber to 80 degC for DN 350 to 2400.

Choosing 5L4B options

Start from the nameplate of the existing meter: nominal diameter, liner, electrode material, flange standard and supply voltage. The supply options are DC 24 V, AC 24 V and AC 100 to 240 V. For electrodes, 316L is standard and Alloy C22 is available. Check the flange: EN 1092-1 PN 10/16, ASME Class 150, AWWA Class D, AS 2129 Table E or AS 4087 PN 16 are all listed. Send the complete code to Seven Star LLC with your RFQ.

Installation and start-up of the 5L4B

Install the sensor so the pipe is always full, observe the grounding instructions and consider the shortened installation length designed to DVGW and ISO. Pressure loss is nil if the pipe has the same diameter. Local operation needs no software because the integrated web server and display provide commissioning menus, and WLAN access allows a laptop or tablet connection.

Maintenance of the 5L4B

The meter has no moving parts, so periodic work is limited to checking cable glands, grounding and the transmitter seal. Use the built-in Heartbeat Technology to document verification. Keep the display cover closed in rain because the standard protection class applies only with the housing shut.

Documents and quotation

Technical Information TI01045D is the datasheet for the 5L4B. Send an RFQ to Seven Star LLC with part number 5L4B, the nameplate order code, size, flange standard and quantity.

Other Models in the Promag 400 Range

Seven Star LLC supplies models from the Promag 400 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser 5L4B Promag L 400 Electromagnetic FlowmeterUltrasonic FlowmetersYou are viewing this model
Endress+Hauser 5W4C Promag W 400 Water Electromagnetic FlowmeterUltrasonic FlowmetersView details
Datasheets & Documents
  • PDF Datasheet Endress+Hauser 5L4B Promag L 400 Electromagnetic Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 5L4B Promag L 400 Electromagnetic

Answers from our engineering team on installation, compatibility and integration.

01What is the 5L4B?
The product root of the Proline Promag L 400, a weight-optimized electromagnetic flowmeter for water and wastewater, DN 25 to 2400.
02Which liners are available for the 5L4B?
Hard rubber, polyurethane and PTFE, with temperature limits of 0 to 80, minus 20 to 50 and minus 20 to 90 degC respectively.
03What accuracy does the 5L4B state?
Plus/minus 0.5 percent of reading plus 1 mm/s, with an optional 0.2 percent of reading plus 2 mm/s.
04Is there a later root than the 5L4B?
Yes, the generation index in TI01045D lists 5L4C, released 1 November 2016, with web server, logbook and WLAN changes.
05How do I quote the 5L4B?
Send an RFQ to Seven Star LLC with 5L4B, the nameplate order code, nominal size, flange standard and quantity.