Brand: Yokogawa
Yokogawa EJA210E Flange Mounted DP Level Transmitter
Description
EJA210E from Yokogawa is a flange mounted differential pressure transmitter. Its high-pressure side carries a large diaphragm directly on a process flange, so there is no impulse line to plug, freeze or leak, and the low-pressure side is a conventional threaded connection. Yokogawa’s general specifications GS 01C31C01-01EN describe it as suited to measuring level, and density of liquids that solidify or precipitate. The output is 4 to 20 mA DC with BRAIN or HART communication; other output versions exist for fieldbus, PROFIBUS PA and low power 1 to 5 V DC with HART. The EJA210E is listed as a discontinued product by the manufacturer, so exact-code replacement enquiries are common in Gulf plants.
Reading the EJA210E model code
The code EJA210E-DMS5G-912NN-WA13B1SW00-B shows how the options stack up. D selects the BRAIN output (J selects HART 5/7, F Foundation Fieldbus, G PROFIBUS PA, Q low power 1 to 5 V). The next letter picks the capsule: M spans 1 to 100 kPa and H spans 5 to 500 kPa. Then follow low-pressure side material, bolting, housing, electrical connection, indicator and bracket codes. The part after the hyphen describes the flange: W for flush, rating (J1 JIS 10K, A1 ANSI 150, D2 DIN PN10/16 and so on), size, flange material, gasket surface, diaphragm material, flushing ring, extension and finally the fill fluid code.
EJA210E technical specifications
| Parameter | Datasheet value |
|---|---|
| Capsule M | Span 1 to 100 kPa; range minus 100 to 100 kPa |
| Capsule H | Span 5 to 500 kPa; range minus 500 to 500 kPa |
| Reference accuracy, M | Plus or minus 0.075 percent of span at or above 10 kPa; formula (0.025 + 0.005 URL/span) below |
| Reference accuracy, H | Plus or minus 0.075 percent of span at or above 100 kPa; formula (0.025 + 0.01 URL/span) below |
| Ambient temperature effect per 28 deg C | M: plus or minus (0.224 percent span + 0.056 percent URL); H: (0.14 percent span + 0.028 percent URL) |
| Static pressure effect per 0.69 MPa | Span plus or minus 0.028 percent; zero plus or minus 0.007 percent of URL |
| Stability | Plus or minus 0.1 percent of URL per 12 months |
| Response time | 120 ms for M and H capsules, dead time 45 ms included |
| Static pressure signal accuracy | Plus or minus 0.5 percent of span at 1 MPa or higher |
| Fill fluid codes | A silicone oil minus 10 to 250 deg C; B silicone oil minus 40 to 120 deg C; D fluorinated oil minus 20 to 120 deg C; P propylene glycol minus 10 to 120 deg C |
| Flush flanges | 3-inch, 2-inch, 1 1/2-inch in JIS 10K and 20K, ANSI 150 and 300, JPI 150 and 300, DIN PN10/16 and 25/40 |
| Wetted materials, high side | 316L SST, Hastelloy C-276 or tantalum diaphragm |
| Weight, flush type | 8.3 kg general use, 9.0 kg high temperature fill; extended type 12.8 kg and 13.5 kg |
| Protection | IP66/IP67, Type 4X |
How EJA210E differs from the EJX118A seal model
The EJX118A uses remote seals on capillaries and so allows the transmitter to sit away from the vessel. The EJA210E mounts the transmitter right on the flange, giving a faster 120 ms response, a tighter 0.075 percent reference accuracy, and no capillary temperature effect, at the cost of fixing the transmitter at the tapping height. Its ambient limit with silicone oil reaches 85 deg C, wider than the 60 deg C ambient limit listed for the EJX118A. Smaller minimum span is another gain: 1 kPa on the M capsule.
Where the EJA210E fits
- Open or closed tank level in oil storage terminals and water towers, where a flange nozzle already exists.
- Liquids that harden, crystallise or deposit scale, including molasses, bitumen, brine and polymer slurries.
- Density measurement across two vertical taps on mixing and settling vessels.
- Food, pharma and sanitary duty with propylene glycol fill, code P.
In each of these jobs the EJA210E replaces a pair of impulse lines and manifold valves with a single flanged connection. That shortens the installation and removes the leak points, and in cold or hot ambient conditions the wide fill fluid choice lets the engineer match the EJA210E to the climate, from minus 40 deg C silicone oil in winter terminals to 250 deg C silicone oil on heated tanks. Check the weight as well: with an ANSI 150 flange the EJA210E is 8.3 kg, light enough for the nozzle and platform on most vessels, whereas an extended-diaphragm version reaches 12.8 kg and may require extra support.
Installation guidance for EJA210E
Bolt the flange to the vessel nozzle with the proper gasket, taking note that ANSI flanges are serrated for wetted code SW while flat gasket contact is used for other codes. Run the low-pressure side to the reference leg or, for an open tank, vent it to atmosphere. After mounting, set LRV and URV with the external zero screw, which offers 0.01 percent of span resolution, or re-range with the push-button indicator. For vacuum duty keep within the working pressure range: 2.7 kPa abs and above for silicone oil, and 51 kPa abs and above for fluorinated oil.
Maintenance of the EJA210E
Because the process face sits at the nozzle, plan service around vessel shutdowns. Check the diaphragm for coating, verify zero against a known level, and keep the vent or drain plugs of the optional flushing ring closed during operation. Self-diagnostics flag CPU and hardware faults; the upscale alarm is 110 percent (21.6 mA or more) and the downscale alarm is minus 5 percent (3.2 mA or less), with NAMUR NE43 limits available by option code.
Documents and quotation
Yokogawa’s general specifications GS 01C31C01-01EN are supplied as the datasheet for the EJA210E. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To receive a quote for the EJA210E, send the RFQ with the full model and suffix code from the nameplate, the capsule range, flange rating and size, fill fluid and the quantity.
Datasheets & Documents
- Datasheet Yokogawa EJA210E Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA210E Flange Mounted DP Level Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What spans does the EJA210E offer?
The M capsule spans 1 to 100 kPa and the H capsule spans 5 to 500 kPa, with ranges of minus 100 to 100 kPa and minus 500 to 500 kPa.
02How accurate is the EJA210E?
Reference accuracy is plus or minus 0.075 percent of span once the span reaches 10 kPa (M) or 100 kPa (H), with a URL-over-span formula for smaller spans.
03Which fill fluids can be fitted to the EJA210E?
Silicone oil codes A and B, fluorinated oil code D for oil-prohibited use and propylene glycol code P for sanitary use.
04How heavy is the EJA210E?
The datasheet gives 8.3 kg for the flush type with general-use fill and 12.8 kg for the extended type, plus 1.5 kg for housing code 2.
05Which output versions exist for the EJA210E?
Code D is BRAIN, J is HART 5/7, F is FOUNDATION Fieldbus, G is PROFIBUS PA and Q is low power 1 to 5 V DC with HART 7.