Brand:

Pepperl+Fuchs KFD2-STV4-Ex1-2 SMART Transmitter Power Supply, 0/2-10 V

Description

Pepperl+Fuchs KFD2-STV4-Ex1-2 overview

The Pepperl+Fuchs KFD2-STV4-Ex1-2 is a one-channel isolated barrier from the K-System of Pepperl+Fuchs that supplies 2-wire and 3-wire SMART transmitters in a hazardous area and can also be used with 2-wire SMART current sources. It transfers the analog input signal to the safe area as an isolated voltage of 0/2 to 10 V, and digital signals are carried in both directions.

The datasheet released on 5 June 2023 lists HART, BRAIN and Foxboro as supported protocols and a safety integrity level of up to SIL 2. Test sockets for HART communicators are built into the terminals, and an internal 250 ohm resistor between terminals 8 and 9 can be used if the loop resistance for HART communication is too low.

Key features of the Pepperl+Fuchs KFD2-STV4-Ex1-2

  • Supplies 2-wire and 3-wire SMART transmitters and 2-wire current sources
  • Voltage output of 0/2 to 10 V
  • HART, BRAIN and Foxboro protocols, bi-directional
  • Terminals with test sockets and an internal 250 ohm resistor
  • Up to SIL 2 according to IEC/EN 61508
  • Powered from 20 to 35 V DC via Power Rail or terminals 14 and 15
  • Ambient temperature from minus 20 to 60 degrees C
  • Housing type B2, 20 mm wide

KFD2-STV4-Ex1-2 technical specifications

The values below are taken from the manufacturer datasheet of the KFD2-STV4-Ex1-2, release date 2023-06-05. Always confirm the current datasheet and the certificates before final engineering.

Parameter Value
Model KFD2-STV4-Ex1-2, SMART Transmitter Power Supply, 1-channel isolated barrier
Signal type Analog input
Safety integrity SIL 2
Supply 20 to 35 V DC, Power Rail or terminals 14+, 15-
Power dissipation / consumption 1.5 W / 1.8 W
Input 0/4 to 20 mA, terminals 1+, 2-, 3 or 5-, 6+
Voltage drop (terminals 5, 6) Up to 2.4 V at 20 mA
Available voltage (terminals 1+, 3) At least 16 V at 20 mA
Output 0/2 to 10 V, terminals 7-, 8+, 9; ripple up to 25 mV
Deviation at 20 degrees C Up to 10 mV including calibration, linearity, hysteresis, loads and supply fluctuations
Temperature influence Up to 20 ppm per K
Ambient temperature Minus 20 to 60 degrees C
Dimensions / mass 20 x 124 x 115 mm (W x H x D), housing type B2 / about 200 g

The hazardous-area parameters are listed per terminal pair in the datasheet. Use the entity values of the exact terminals you wire, and refer to the certificate for the permitted cable parameters of your installation.

Typical applications in oil and gas, utilities, water and manufacturing

Loop-powered SMART transmitters for pressure, differential pressure, level, flow and temperature are found throughout refineries, gas gathering stations, power plants and desalination works in Oman and the wider GCC. Where such a transmitter sits in a hazardous area, an intrinsically safe interface is needed between the field and the control room, and the KFD2-STV4-Ex1-2 is designed for that duty in marshalling cabinets feeding DCS and PLC analog input channels.

In utilities, water and wastewater works and manufacturing sites, the same interface is typical near fuel stores, chemical dosing areas and biogas digesters. Because HART data can pass through the module, asset management software and handheld communicators can reach the transmitter for configuration and diagnostics, which is one reason buyers specify the KFD2-STV4-Ex1-2 as a like-for-like spare.

Selection and compatibility notes for KFD2-STV4-Ex1-2

Begin with the transmitter. Confirm that its supply voltage requirement, its current range and its entity parameters match the field-side data of the KFD2-STV4-Ex1-2, and confirm that the control system input accepts the output type of the module. Check the loop resistance as well, since HART communication needs enough load in the loop.

Then consider the cabinet. Decide early how power will be distributed, because the KFD2-STV4-Ex1-2 is intended for the supply method named in the datasheet, and check that the housing width suits your rack or termination arrangement. If your plant standard calls for another channel count or safety integrity level, tell us before ordering so that we can compare neighbouring variants against your loop list.

Installation and commissioning of the KFD2-STV4-Ex1-2

Before mounting the KFD2-STV4-Ex1-2, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail, a termination board or its own supply terminals. Mount it in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits.

Wire the KFD2-STV4-Ex1-2 only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KFD2-STV4-Ex1-2 can be compared with the commissioning values.

Maintenance and service life

The KFD2-STV4-Ex1-2 has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface.

If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KFD2-STV4-Ex1-2 entity parameters before it returns to service.

Related products and ordering notes

Customers who ask for the KFD2-STV4-Ex1-2 often need neighbouring models or accessories from the same system, such as other K-System isolated barriers, the Power Rail and power feed modules, KFA6 power supplies and the matching NAMUR sensors. If you are standardising a cabinet or a spare parts list on one family, send us the loop list or the equipment list and we can quote the matching items together.

When you send an enquiry for the KFD2-STV4-Ex1-2, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.

Frequently asked questions about KFD2-STV4-Ex1-2

The KFD2-STV4-Ex1-2 is a SIL 2 capable SMART transmitter power supply with a 0/2 to 10 V output, HART, BRAIN and Foxboro support, test sockets and a 20 mm wide housing.

Documents and quotation

A copy of the manufacturer datasheet for the KFD2-STV4-Ex1-2 is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KFD2-STV4-Ex1-2, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.

Datasheets & Documents
  • PDF Datasheet KFD2-STV4-Ex1-2 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs KFD2-STV4-Ex1-2 SMART Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What output does the KFD2-STV4-Ex1-2 provide?
An isolated voltage output of 0/2 to 10 V, instead of the 0/4 to 20 mA current output of the STC4 series.
02Which SMART protocols are supported?
HART, BRAIN and Foxboro, with digital signals transferred in both directions.
03Does it have test sockets?
Yes, test sockets for HART communicators are integrated in the terminals, and an internal 250 ohm resistor is available between terminals 8 and 9.
04Which documents are available for the KFD2-STV4-Ex1-2?
The manufacturer datasheet is attached to this page, and certificates or manuals can be requested together with your RFQ for the KFD2-STV4-Ex1-2.
05How do I order the KFD2-STV4-Ex1-2?
Send an RFQ with the part number KFD2-STV4-Ex1-2, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.