Moore Industries HIX/4-20MA/4-20MA/12-42DC [DIN] HART Isolator

Description

Moore HIX/4-20MA/4-20MA/12-42DC [DIN] overview

The Moore HIX/4-20MA/4-20MA/12-42DC [DIN] is a two-wire, loop-powered HART isolator from the Moore Industries HIT/HIX family. It isolates a 4-20 mA input signal and passes the superimposed HART digital data to the output, drawing power from the output side of the loop.

In the model string the 12-42DC code identifies the loop-powered supply. The HIX typically takes its power from a secondary receiving device such as a DCS or PLC. The manufacturer positions it as an economical way to protect and enhance a HART investment.

The HIX/4-20MA/4-20MA/12-42DC [DIN] fits cabinets where a field transmitter signal needs to be passed to more than one device, or where HART data must reach an asset-management system through an isolation barrier.

The part number written as HIX/4-20MA/4-20MA/12-42DC [DIN] is the model string given in the manufacturer datasheet as a worked ordering example for the HIX family, so it describes one complete, orderable configuration rather than a loose product family. Every field of the string (unit, input, output, supply or power, option and housing) can be changed when a different configuration is needed, and the datasheet table lists the allowed choices. If your plant standard differs from this example, send the configuration you need with your RFQ and we will check it against the table.

Key features of the Moore Industries HIX/4-20MA/4-20MA/12-42DC [DIN]

  • Isolation protects I/O cards from surges, spikes and transients, and breaks the common galvanic path between transmitter and receiver.
  • Passes HART digital data superimposed on the 4-20 mA signal.
  • Allows area isolation: devices on isolated legs can be removed without affecting other equipment.
  • Lets one transmitter’s HART signal be shared safely with a secondary receiving device.
  • Compact DIN housing that snaps onto Top Hat or G-type rails; also available in an aluminum case or an R-BOX field enclosure.
  • Option -IZ100 reduces input resistance to 100 ohms.

Technical specifications for HIX/4-20MA/4-20MA/12-42DC [DIN]

Parameter Value
Model string Moore HIX/4-20MA/4-20MA/12-42DC [DIN]
Input 4-20 mA into 250 ohms, HART digital data superimposed
Output Isolated 4-20 mA into up to 600 ohms with 24 Vdc power; HART data superimposed
Power 12-42 Vdc, loop powered
Accuracy Plus or minus 0.1% of span
Stability Plus or minus 0.2% of reading per year
Isolation HIX: 1500 Vrms between input, output and case for 1 minute
Response time 100 ms maximum to 99% of output (analog output)
Ambient temperature range -20 to +85 degrees C
Certifications Non-incendive Class I, Division 2, Groups A, B, C, D, T4A at -20 to +70 degrees C ambient; CE conformant, EMC Directive 2014/30/EU, EN 61326

The values above come from the manufacturer datasheet for the HIX family. Specifications can depend on the option and housing chosen, so always read the matching page of the datasheet before you finalise a purchase specification, and keep the full model string on your purchase documents.

Typical applications in Oman and the GCC

Signal isolators are installed to protect measurement loops from ground loops and common-mode faults. Typical places to use them are:

  • Oil and gas control rooms, where field signals are isolated before they enter DCS, PLC or safety-system input cards.
  • Power plants and utilities, for signal sharing between a control system and a recorder or monitoring package.
  • Water treatment and pumping stations, where long cable runs and several earth points can create ground-loop errors.
  • Manufacturing plants that need to interface non-isolated transmitters with modern input cards.

For safety instrumented systems the datasheet notes that HART data can still be passed from the field while input isolation is provided.

Selection and compatibility notes

Choose between the two-wire HIX and the four-wire HIT. The HIX is loop-powered from the receiver side and needs no separate mains supply, while the HIT is line powered with 24DC, 117AC or 230AC supply and provides transmitter excitation.

The datasheet notes that the HIX can operate with powered inputs from both sides, which makes it a fix for bucking power supplies while still passing HART signals.

Questions to settle before ordering HIX/4-20MA/4-20MA/12-42DC [DIN]:

  • Does the receiver supply at least the 12 Vdc required by the HIX?
  • Is the input loop-powered or four-wire?
  • Do you need the 100 ohm input option (-IZ100)?
  • Is HART communication needed through the isolator?
  • Is the area classification Division 2 only?

Installation and commissioning

Snap the unit onto the rail and connect the input transmitter and output receiver per the terminal diagram. Check that the receiver provides the required loop supply and that the total loop resistance, including the HART 250 ohm resistor, is within the output capability of 600 ohms with 24 Vdc.

Verify the HART communication end-to-end with a communicator or host system after installation.

Maintenance and service life

Check that HART communication still reaches the host and that the isolation has not been bypassed by new wiring. Keep a record of the loop resistance.

Replace the unit if accuracy drift exceeds the specification during a calibration check.

Related products and ordering notes

The HIM smart HART loop interface and monitor and the HES HART to Ethernet gateway on this site pair well with HART isolators.

Provide the full model string when requesting a quotation.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model designations belong to their owners and are used here only to identify the equipment you are asking about.

Frequently asked questions in brief

  • What does the HIX/4-20MA/4-20MA/12-42DC [DIN] do? It isolates a 4-20 mA loop and passes HART data, using loop power from the output side.
  • What isolation does the HIX/4-20MA/4-20MA/12-42DC [DIN] give? The datasheet lists 1500 Vrms between input, output and case for the HIX.
  • What load can the HIX/4-20MA/4-20MA/12-42DC [DIN] drive? The output drives up to 600 ohms with 24 Vdc power.
  • Can the HIX/4-20MA/4-20MA/12-42DC [DIN] solve bucking power supplies? Yes, the datasheet states that the HIX can operate with powered inputs from both sides.
  • How can I get a price for the HIX/4-20MA/4-20MA/12-42DC [DIN]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.

Documents and quotation

The manufacturer datasheet for the HIX family is available for download from this page, and it contains the full ordering table, dimensional drawings and wiring diagrams referred to above. To request a quotation, send an RFQ that includes the part number HIX/4-20MA/4-20MA/12-42DC [DIN], the quantity you need, the delivery location in Oman or the GCC and any special requirements such as certification or documentation. We will confirm availability and lead time and reply with a written offer. Please check the datasheet and your own hazardous-area and safety requirements before you place an order.

Datasheets & Documents
  • PDF Datasheet HIT HIX HART Isolator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the Moore Industries HIX/4-20MA/4-20MA/12-42DC [DIN]

Answers from our engineering team on installation, compatibility and integration.

01What does the {pn} do?
It isolates a 4-20 mA loop and passes HART data, using loop power from the output side.
02What isolation does the {pn} give?
The datasheet lists 1500 Vrms between input, output and case for the HIX.
03What load can the {pn} drive?
The output drives up to 600 ohms with 24 Vdc power.
04Can the {pn} solve bucking power supplies?
Yes, the datasheet states that the HIX can operate with powered inputs from both sides.
05How can I get a price for the {pn}?
Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.