Brand: Beamex
Beamex 8081755 BC15 Power Supply for MC6
Description
Overview of Beamex BC15 power supply for MC6 Beamex 8081755
The Beamex 8081755 is the BC15 power supply and battery charger for the MC6 calibrator. The input range is 100 to 240 VAC, so it can be used on the mains supplies found across Oman and the GCC with a suitable power cord.
A replacement supply is a common spare when a charger is lost or damaged on a field job.
This page describes Beamex BC15 power supply for MC6 for buyers who need the exact part number Beamex 8081755. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below is taken from the manufacturer published product pages and brochures.
Key features of 8081755
- Order code: 8081755.
- Description: BC15 power supply for MC6.
- Input voltage: 100 to 240 VAC.
- Mains frequency: 50 to 60 Hz (MC6 charger supply).
- Power cord: Ordered separately; US plug cord is 8081765.
- Charging time in MC6: Approximately 4 hours.
Technical specifications for 8081755
| Order code | 8081755 |
|---|---|
| Description | BC15 power supply for MC6 |
| Input voltage | 100 to 240 VAC |
| Mains frequency | 50 to 60 Hz (MC6 charger supply) |
| Power cord | Ordered separately; US plug cord is 8081765 |
| Charging time in MC6 | Approximately 4 hours |
All values above come from the manufacturer documentation and may change with later revisions. Please quote 8081755 when you need the matching datasheet or a confirmation of the current revision.
Typical applications in Oman and the GCC
A dependable charger is essential for calibrators that are used on every shift. Instrument teams in Oman and the GCC rely on power supplies that accept a wide mains range and travel easily between plant, workshop and vehicle.
Spare supplies are also kept at remote sites, offshore platforms and contractor camps, where a damaged or misplaced charger would otherwise leave an instrument unusable until the next supply run.
The part is relevant wherever the related calibration equipment is used: oil and gas, utilities, water, process manufacturing and calibration service providers in Oman and the wider GCC.
Equipment used in Oman and the wider GCC faces high ambient temperatures, dust and coastal humidity. Keep instruments and accessories out of direct sun, avoid leaving them in closed vehicles, and allow cold equipment to acclimatise before use when moving from an air-conditioned room to an outdoor unit. Cap connectors and threads when they are not in use so that sand and moisture stay out.
Selection and compatibility notes for 8081755
It is delivered as part of a new MC6. Select the power cord separately, for example 8081765 for a US plug. Country-specific cords for EU, UK and AU plugs are also listed by the manufacturer for the related BC15-Ex.
Do not use the BC15 for the MC6-Ex: that calibrator needs the BC15-Ex (8075784).
Before ordering 8081755, confirm the model and, where relevant, the serial number or option code of the instrument it will serve. Confirm voltage, plug type, thread type or pressure rating as applicable, and check the manufacturer documentation for the firmware or hardware revision of the equipment.
If an item looks similar but carries a different part number, do not assume interchangeability. A short note of the calibrator model and application lets us confirm the match for 8081755 before it is supplied.
Installation and commissioning of 8081755
Connect the power cord to the supply first, then to the mains, and finally to the calibrator charging socket. Check that the cord plug matches the local socket type; the power cord is a separate part number from 8081755. Allow the calibrator to charge in a dry, ventilated place within the temperature limits in its specification.
Do not cover the supply while charging, and do not use a damaged cable. Disconnect when charging is complete if the instrument will be stored for a long period.
Maintenance and care
Inspect the cable and plug regularly for cuts, kinks and heat marks and replace the unit if there is any damage. Keep the unit dry and away from dust and direct heat. Label each supply with the calibrator it belongs to so that the right one is used for each model.
Use 8081755 only with the calibrator it is listed for, because charger and battery are matched.
Calibration is only as useful as its records. Keep a log of serial numbers, certificate dates, replacement parts and any faults, and store the manufacturer documents with the equipment. This makes audits easier, helps predict when spares will be needed, and shortens the time needed to prepare a purchase request when a part has to be replaced at short notice.
Related products and ordering notes for 8081755
Related items are the matching battery pack, the country-specific power cord and a carrying case. List them together to receive a single quotation.
Hard-to-find and discontinued spare parts are a daily topic for maintenance planners in oil, gas, power and water facilities. When a plant standardises on one calibrator family, a small stock of the exact spares is far cheaper than a day of lost production, and an early enquiry gives the supplier time to confirm availability and shipping options to Oman and neighbouring countries.
Please note that Seven Star LLC prepares each quotation for 8081755 against the exact part number, so a request that quotes the number and the quantity is answered faster than a general description.
The part number 8081755 should be quoted exactly as printed in this page, because accessories and spares with similar descriptions often differ by one digit.
Frequently asked questions about 8081755
- What input voltage does 8081755 accept? 100 to 240 VAC, according to the manufacturer documentation for 8081755.
- Is a power cord included? The manufacturer says to select the power cord separately, for example the US cord 8081765.
- Which calibrator does it charge? The MC6 calibrator, according to the manufacturer documentation for 8081755.
- Can it charge the MC6-Ex? No. The MC6-Ex requires the BC15-Ex charger, 8075784.
- How long does a charge take? About 4 hours in the MC6 according to the brochure.
Documents and quotation
The official Beamex MC6 User Manual is attached to this page as a PDF. Its charging section describes the BC15 power supply/charger that ships with the MC6 and how the calibrator behaves while it is connected. Quote order code 8081755 in your request and we will confirm compatibility with your unit in a written quotation.
Datasheets & Documents
- Datasheet Beamex MC6 User Manual (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 8081755 BC15 Power Supply for MC6
Answers from our engineering team on installation, compatibility and integration.
01What input voltage does 8081755 accept?
100 to 240 VAC, according to the manufacturer documentation for 8081755.
02Is a power cord included?
The manufacturer says to select the power cord separately, for example the US cord 8081765.
03Which calibrator does it charge?
The MC6 calibrator, according to the manufacturer documentation for 8081755.
04Can it charge the MC6-Ex?
No. The MC6-Ex requires the BC15-Ex charger, 8075784.
05How long does a charge take?
About 4 hours in the MC6 according to the brochure.