Brand: GESTRA
GESTRA DK 47 Thermodynamic Steam Trap PN 63 / Class 600
Description
GESTRA DK 47 Thermodynamic Steam Trap PN 63: overview
The GESTRA DK 47 is a thermodynamic steam trap made of stainless steel with an integral strainer. It is rated PN 63 / Class 600 and is offered in screwed sizes from 3/8 to 1 inch. The GESTRA DK 47 L version is intended for low condensate flowrates and the DK 47 H version for larger flowrates. The same datasheet also covers the DK 57, which has no integral strainer.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list the DK 47 for buyers who need an exact GESTRA type for a repair, a replacement or a new project and want a clear technical summary before they ask for a quotation. Everything below is condensed from the manufacturer datasheet, so you can compare the DK 47 with the line conditions on your own drawings. Where a value is not stated in the datasheet, we leave it out rather than guess.
GESTRA equipment is common on steam and condensate systems, boiler houses and process plants, and many installed units in Omani and Gulf facilities are now several years old. That is why buyers often search by the exact type designation such as DK 47. Matching the designation, nominal size, pressure rating and connection type is the surest way to get the right replacement, and our team can help check these details against the nameplate or the earlier project documentation before a quotation is issued.
Key features of the DK 47
The datasheet describes the following points about the DK 47. They explain why this thermodynamic steam trap is chosen for its duty and what to look for when comparing it with other options.
- Stainless steel body, cap and valve disc.
- Integral strainer on the DK 47 protects the seat from scale and debris.
- Two capacity versions: L for low condensate flowrates, H for larger flowrates.
- Admissible backpressure up to 80 percent of the upstream pressure.
- Compact design with 30 mm space needed above the trap for opening.
- Screwed connections to NPT and BSP (ISO 228/1).
Technical specifications of the DK 47
The table below summarises the main data for the DK 47 taken from the manufacturer datasheet. Always confirm the final pressure and temperature limits against the datasheet for the exact version and connection you plan to order, because ratings depend on connection type and size.
| Parameter | Value |
|---|---|
| Nominal sizes | DN 10, 15, 20, 25 (3/8, 1/2, 3/4, 1 inch) |
| Pressure rating | PN 63 / Class 600 |
| Max. operating pressure PMO | 42 bar g (609 psi g) |
| Max. allowable temperature TMA | 400 C (752 F) |
| Body | A743 CA40 / 1.4027 |
| Cap | AISI 416 / 1.4005 |
| Valve disc | AISI 420 / 1.4021 |
| Strainer | A182 F304 / 1.4301 |
| Backpressure | Up to 80 percent of upstream pressure |
| Weight | 0.75 kg to 1.6 kg depending on size and version |
Typical applications in Oman and the GCC
The DK 47 is a thermodynamic steam trap, and the following use cases show where a unit of this kind is typically applied across oil and gas, utilities, water and manufacturing in Oman and the wider GCC. They are examples based on the described function and not a guarantee of suitability, so the actual operating data should always be checked.
- Steam tracing lines and drip legs on refinery and petrochemical piping use thermodynamic traps because they are small, light and tolerate high pressure.
- In power plants and utilities, superheated and high-pressure steam mains need a trap with a rated temperature up to 400 degrees C, which this datasheet states.
- Manufacturing plants in the GCC use compact stainless traps on steam lines in food, beverage and chemical production where corrosion resistance is useful.
Selection and compatibility notes
Selecting the DK 47 correctly starts with the process data. Collect the operating pressure, the maximum and minimum temperature, the fluid, the flowrate and the connection standard of the existing pipework, then compare them with the datasheet. The notes below summarise the main decision points for this model.
- Select L or H according to the condensate quantity to be discharged, using the capacity chart in the datasheet.
- Check that the backpressure stays below 80 percent of the upstream pressure.
- Use the DK 57 where the integral strainer is not wanted or a separate strainer is already installed.
Installation and commissioning of the DK 47
Before installing the DK 47, flush the line to remove weld spatter, scale and construction debris, because even a robust thermodynamic steam trap can be damaged or held open by foreign particles. Check that the flow direction arrow or the marked inlet on the DK 47 matches the piping, and confirm that the nameplate type, size and pressure rating agree with the purchase documents.
Support the pipework so that no piping stress is transferred to the body of the DK 47. Use new gaskets of a type suitable for the fluid and temperature, tighten flange or union bolts evenly and in a cross pattern, and follow the instructions in the manufacturer installation and operating manual for the exact model. If the equipment is used in a potentially explosive area, the plant operator remains responsible for zoning and for preventing static charge, as the datasheet explains for GESTRA equipment.
During commissioning, bring the system up gradually. Open isolation valves slowly, vent trapped air where the design allows, and observe the DK 47 during the first warm-up for leaks at joints and for unusual noise or vibration. Record the first operating pressure and temperature so that later inspections have a reference.
Maintenance and service
The cap, valve disc, plug and strainer are separate listed parts, so the trap can be opened and the disc inspected with 30 mm of clearance.
When ordering, state operating pressure, backpressure, condensate quantity, design, size, connections and mounting position.
A short routine inspection plan helps the DK 47 last longer. Note the date of installation, the service conditions and any events such as water hammer or overpressure. At each planned shutdown, inspect the visible joints, check for external corrosion or leakage and compare performance against the commissioning record. Only use spare parts and gaskets that suit the exact type and rating of the DK 47, and isolate and depressurise the line fully before any work is started.
Related products and ordering notes
Orders for the DK 47 should state the type designation, nominal size, pressure rating, end connection standard, material or version and the quantity required. If you are replacing an existing unit, add the nameplate data and a photograph of the nameplate when possible. The manufacturer family also includes other steam, condensate and flow control products, and we can quote related items together with the DK 47 when you send a combined enquiry. Seven Star LLC does not publish prices on this page, so each enquiry is answered with a written quotation.
Frequently asked questions
What is the maximum operating pressure of the DK 47? The datasheet gives a maximum operating pressure of 42 bar g and a maximum allowable temperature of 400 degrees C.
What is the difference between L and H? DK 47 L is intended for low condensate flowrates and DK 47 H for larger condensate flowrates.
Does it have a strainer? Yes. The DK 47 has an integral strainer, listed as A182 F304 material.
Which connections are available? Screwed sockets to NPT and BSP according to ISO 228/1.
How much backpressure is admissible? Up to 80 percent of the upstream pressure, according to the datasheet.
Documents and quotation
The manufacturer datasheet for the DK 47 is attached to this page as a PDF so you can verify every value above and share it with your engineering team. To receive a quotation, send an RFQ that includes the part number DK 47, the nominal size, the pressure rating and connection type, and the quantity you need. Our team in Muscat will confirm availability and lead time and reply with a written offer for delivery to Oman and the GCC.
Datasheets & Documents
- Datasheet GESTRA DK 47 Thermodynamic Steam Trap PN 63 / Class 600 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
GESTRA is the German steam and condensate specialist behind the UNA ball float steam traps, the MPA blowdown valves and a long line of boiler level and conductivity controls. It was founded in Bremen in 1902 by Gustav F. Gerdts, and has been part of Spirax Sarco since 2017.
Seven Star LLC is an independent supplier in Muscat. We list GESTRA steam traps, blowdown valves and boiler control equipment, and supply GESTRA parts and spares to boiler houses and process plants in Oman and the GCC.
GESTRA company profile
| Established | 29 October 1902, Bremen, Germany, by Gustav Friedrich Gerdts; renamed Gustav F. Gerdts KG in 1907 |
|---|---|
| Ownership history | Became a stock corporation (GESTRA AG) in 1987, was taken over by Flowserve in 2002, and has been part of the Spirax Sarco group since 2017 |
| Product families | Steam traps, non-return and check valves, boiler blowdown valves, control valves, and boiler control electronics for level, conductivity and temperature |
| Applications | Steam boilers, steam distribution and condensate return in process plants, power stations, hospitals, food and textile plants |
Milestones
- 1902: Gustav Friedrich Gerdts founds the company in Bremen on 29 October.
- 1907: The company is renamed Gustav F. Gerdts KG.
- 1987: It becomes a stock corporation, GESTRA AG.
- 2002: Flowserve takes over GESTRA.
- 2017: GESTRA becomes part of the Spirax Sarco group.
GESTRA products we list
| Series | Type | What it does |
|---|---|---|
| UNA 45, UNA 16, UNA 38 | Ball float steam traps | Continuous condensate discharge from heat exchangers and process equipment; the UNA 38 is the high-pressure version (PN 100) |
| BK 45 | Bimetallic steam trap | Robust trap for steam main drainage and tracing, resistant to water hammer |
| MK 45, TK 23, SMK 22-81 | Thermostatic steam traps | Air venting and condensate discharge; the SMK 22-81 is the sanitary version for clean steam |
| MPA 46 | Rapid-action blowdown valve | Short, intermittent bottom blowdown that removes sludge from the boiler |
| NRS 1-54, NRR 2-50, NRR 2-60, NRGT 26-2 | Boiler level controls | Water level limiting, feedwater control and continuous level measurement |
| LRGT 16-1, LRR 1-50 | Conductivity measurement and control | Keeps boiler water conductivity in range through continuous blowdown |
| TRS 5-50 | Safety temperature limiter | SIL 3 temperature limiting for boilers and hot water systems |
The type of steam trap follows the duty. Ball float traps discharge condensate as soon as it forms, which suits heat exchangers with changing loads. Thermostatic and bimetallic traps hold condensate back slightly and suit steam mains, tracing and air venting. On the boiler itself, GESTRA level and conductivity electronics work as a system: electrodes or transmitters in the boiler, controllers in the panel, and the feedwater and blowdown valves they drive.
Where GESTRA products are used
In Oman and the GCC, GESTRA equipment is used in boiler houses of refineries, petrochemical and fertiliser plants, power and desalination stations, food and beverage plants, laundries, hotels and hospitals.
Ordering GESTRA parts: what we need
Send the type designation, pressure rating (PN) and connection size (DN), the end connection (flanged, screwed or socket weld), the operating pressure and condensate load for steam traps, and the supply voltage and bus type (CAN bus, 4-20 mA) for control equipment. For electrodes, add the insertion length.
Facts checked against GESTRA company history and Bremen city records, October 2026.
Browse GESTRA products by category: Liquid Analysis Sensors.
FAQ
Questions about the GESTRA DK 47 Thermodynamic Steam Trap PN 63 / Class
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum operating pressure of the DK 47?
The datasheet gives a maximum operating pressure of 42 bar g and a maximum allowable temperature of 400 degrees C.
02What is the difference between L and H?
DK 47 L is intended for low condensate flowrates and DK 47 H for larger condensate flowrates.
03Does it have a strainer?
Yes. The DK 47 has an integral strainer, listed as A182 F304 material.
04Which connections are available?
Screwed sockets to NPT and BSP according to ISO 228/1.
05How much backpressure is admissible?
Up to 80 percent of the upstream pressure, according to the datasheet.


















Reviews