Brand:

AMETEK 563075928 5000 Moisture Analyzer Sensor Cell Standard

Description

AMETEK 563075928 overview

AMETEK 563075928 is the standard timing sensor cell for the AMETEK 5000 process moisture analyzer. The AMETEK listing describes it as cell 5000 HT TRD standard cycle calibration, in the group 5000 sensor (cell), standard timing. The 5000 measures moisture by monitoring the vibrational frequency change of a hygroscopically sensitised quartz crystal exposed alternately to wet sample and dry reference gas for 30 second periods. That differential principle is why the cell is the part that gets replaced after contamination or long service.

The AMETEK 5000 is a process moisture analyzer for vapours and gases. The datasheet describes an explosion-proof field unit containing the sample cell and switching valves, a controller that can be separated by up to 600 m (2000 ft), an external molecular sieve dryer supplying reference gas, and a differential measurement principle with continuous diagnostics.

Key features of 563075928

  • Standard timing sensor cell for the 5000 moisture analyzer
  • Quartz crystal exposed alternately to sample and dry reference for 30 seconds
  • Calibrated range 0 to 1000 ppmv per the datasheet
  • Datasheet notes unsaturated hydrocarbons and oils can damage trace moisture sensors
  • Photo shows the cell on a circuit board with orange nuts
  • Replaced as a unit in the field unit

563075928 technical specifications

Item Detail
Part number 563075928
Description Cell 5000 HT TRD standard cycle calibration
Category (AMETEK) 5000 sensor (cell), standard timing
Calibrated range (datasheet) 0 to 1000 ppmv
Accuracy (datasheet) Plus or minus 1 ppmv or 5 percent of reading, whichever is greater
Sensitivity (datasheet) 0.1 ppmv or 0.5 percent of reading, whichever is greater
Sensitivity 0.1 ppmv or 0.5 percent of reading
Accuracy Plus or minus 1 ppmv or 5 percent of reading
Reproducibility 0.2 ppmv or 1 percent of reading
Outputs Two 4-20 mA signals, RS485 serial port, three alarms
Allowable inlet pressure 207 to 690 kPa gauge (30 to 100 psi)
Controller to field unit Up to 600 m (2000 ft) apart
Field unit ambient -20 to 50 C, -40 to 50 C with optional electric heat

Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 563075928. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.

Typical applications in oil and gas, utilities, water and manufacturing

The datasheet lists catalytic reforming, moisture in olefins and moisture in natural gas, serving natural gas, petrochemical, refinery and chemical markets. In Oman and the GCC the same duties appear in gas processing trains and petrochemical complexes.

Where 563075928 is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 563075928

Confirm the analyzer is a 5000 (single-point or multi-point) and not a 2850 or 3050 before ordering, since each uses a different sensor cell.

Part number 563075928 is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

Use the 5000 single-point or multi-point user manual for the sensor change. Depressurise and isolate the explosion-proof field unit according to site hazardous area rules, open it, replace the sensor cell with 563075928 and reconnect the lines. After closing the field unit, allow the analyzer to cycle through its wet and dry reference periods before checking readings.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 563075928. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

The 5000 uses continuous diagnostics so a fouled sensor is detected rather than silently reading. Replace the cell after contamination events such as compressor oil carry-over.

Related products and ordering notes

Compare with the 2850 cell 563075938 and the external dryer parts of the 5000 sample system.

For a spare parts plan, list 563075928 against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Process plants in Oman and the wider GCC run long between shutdowns, which is why maintenance planners check part numbers early and hold critical spares. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We source against the exact number you give us and confirm availability and lead time before you commit.

Frequently asked questions about 563075928

  • What is AMETEK 563075928? It is the standard timing sensor cell for the AMETEK 5000 process moisture analyzer.
  • How does the 5000 measure moisture? A hygroscopically sensitised quartz crystal is exposed alternately to wet sample and dry reference gas for 30 second periods, and the frequency change is monitored.
  • What can damage the sensor? The datasheet names unsaturated hydrocarbons, compressor oils, oxygen and carbon dioxide among substances that can damage trace moisture sensors.

Documents and quotation

The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 563075928, send the RFQ with the part number 563075928, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Datasheets & Documents
  • PDF Datasheet AMETEK 5000 Moisture Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 563075928 5000 Moisture Analyzer Sensor Cell

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 563075928?
It is the standard timing sensor cell for the AMETEK 5000 process moisture analyzer.
02How does the 5000 measure moisture?
A hygroscopically sensitised quartz crystal is exposed alternately to wet sample and dry reference gas for 30 second periods, and the frequency change is monitored.
03What can damage the sensor?
The datasheet names unsaturated hydrocarbons, compressor oils, oxygen and carbon dioxide among substances that can damage trace moisture sensors.
04What is the calibrated range?
The datasheet gives 0 to 1000 ppmv with trend information above that.
05How do I request a quotation for 563075928?
Send the part number 563075928, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.