Brand:

Yokogawa EJX210B Wireless flange mounted dp transmitter

Description

Yokogawa EJX210B Wireless Flange Mounted Differential Pressure Transmitter: overview

The Yokogawa EJX210B is a wireless flange mounted differential pressure transmitter for tank level and density measurement. The seal diaphragm is mounted directly on the flange at the vessel wall, so there are no impulse lines to plug with solidifying or precipitating liquids.

Seven Star LLC lists the Yokogawa EJX210B for engineers, maintenance planners and procurement teams in Oman and across the GCC who need to replace an installed unit, extend a loop or specify a new instrument for an oil and gas, utility, water or manufacturing project. The page below summarizes the key facts from the manufacturer datasheet so that a first technical review can be done before the full document is opened.

Key features of the EJX210B

  • EJX210B communicates with the ISA100.11a protocol at 250 kbps in the license-free 2.4 GHz ISM band.
  • Radio security is AES 128 bit, and network joining and parameter setting use infrared communication between devices.
  • Update time is selectable from 0.5 second to 60 minutes for the published process value.
  • Dedicated lithium-thionyl chloride battery pack, with an external 10.5 to 30 V DC supply as an alternative where available.
  • IP66/IP67 and Type 4X enclosure, with a detachable 2 dBi antenna or an N connector for a remote antenna.
  • Software download over the wireless link lets the EJX210B firmware be updated without removing the transmitter from the plant.

EJX210B technical specifications

Capsule M spans 1 to 100 kPa and capsule H spans 5 to 500 kPa. Reference accuracy is plus or minus 0.075% of span with capsule-dependent terms for narrow spans. The high-pressure side process temperature depends on the fill fluid selected, while the low-pressure side is limited to -40 to 120 C.

Flush type and extended type seals are offered, with the extended type suited to vessels where the nozzle is recessed or lined.

Because the unit is battery powered and wireless, it is also suited to retrofit level points on older tanks.

The table lists the main values stated in the datasheet for this model. Values depend on the selected capsule, wetted material and options, so always confirm the final model code with the datasheet before ordering.

Parameter Value
Type Wireless flange mounted differential pressure transmitter (ISA100.11a)
Capsule M span 1 to 100 kPa (4 to 400 inH2O)
Capsule H span 5 to 500 kPa (20 to 2000 inH2O)
Reference accuracy Plus or minus 0.075% of span
Ambient temperature -40 to 85 C (-30 to 80 C LCD visible range), within the fill fluid operating range
Process temperature, low pressure side -40 to 120 C
Process temperature, high pressure side Depends on fill fluid, see Table 1 of the datasheet
Wireless protocol ISA100.11a
Weight (flush type) 11.1 kg with 3-inch ANSI Class 150 flange
Weight (extended type) 15.6 kg with 4-inch ANSI Class 150 flange, 100 mm extension

Typical applications in Oman and the GCC

  • Oil and gas. Remote wellpads, pipelines and tank farms are typical places for the EJX210B: level and density in vessels with solidifying or precipitating liquids, slurry tanks, sludge and bitumen service and viscous product storage, with no need for signal cabling over long distances.
  • Utilities and power. Power and utility sites use wireless points like the EJX210B to add monitoring to existing plant without opening cable trays or modifying cabinets.
  • Water and desalination. Pumping stations, reservoirs and remote water network points can send data over the ISA100.11a network with a EJX210B, which helps in sites that are far from the control building.
  • Manufacturing and process. Brownfield process units and temporary test setups use the EJX210B when a new measurement is needed quickly and a wired point would be costly to install.

Selection and compatibility notes

A EJX210B should be selected together with a wireless network plan. The device talks ISA100.11a on the 2.4 GHz band, so the gateway and any field routers must be placed with line of sight and with the radio environment of the plant in mind. The antenna can be a detachable 2 dBi unit, or a version with an N connector for a remote antenna.

Update time is a trade-off between data freshness and battery life. The datasheet quotes a typical battery life of 10 years at 30 seconds and 5 years at 10 seconds under defined conditions, and vibration or temperature extremes can shorten it, so plan battery replacement in the maintenance calendar and use the external-power version where fast updates are needed permanently.

Check wetted materials, capsule and pressure ratings as for any transmitter in this family, and confirm the intrinsically safe approvals listed in the datasheet for the area where the EJX210B will be installed.

Installation and commissioning of the EJX210B

Install the EJX210B within range of the wireless gateway or a field router, with the antenna pointing upward and clear of large metal obstructions. Join the device to the network using infrared communication, set the update time, and confirm in the gateway that the measurement and the battery status are reported correctly before leaving site.

Record the device tag, network address and update time in the commissioning record, and keep the battery pack installation date for later replacement planning. Perform a zero check with the process isolated before the EJX210B is handed over to operations.

Maintenance and calibration

Maintenance of the EJX210B centers on the battery pack and the network. Review battery status in the gateway, plan pack replacement before the end of the expected life, and check signal quality after plant changes that add metal structures. Verify zero and span against a reference at your usual calibration interval and keep the housing covers and antenna connection tight.

Good wireless practice also includes keeping a record of the network topology, the signal strength reported by each device and the date of the last battery change. Checking these values during routine rounds shows early signs of radio problems or an ageing battery long before a measurement is lost, and it keeps the plant data trustworthy for operators and reliability engineers alike.

Related products and ordering notes for the EJX210B

Other Yokogawa models in the same product area include EJX118B, EJX110B, EJXC80A and EJX430B, which may suit neighboring points on the same plant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify compatible equipment.

When you ask for a quotation, state the exact model code, the measuring range, the output type, any hazardous area approval and the quantity. A complete code lets us confirm that the unit matches the installed unit or the project specification, and it avoids delays caused by option mismatches.

Frequently asked questions in short

What is the Yokogawa this model? The Yokogawa this model is a wireless flange mounted differential pressure transmitter. The this model is a wireless flange mounted differential pressure transmitter for tank level and density measurement. What measuring ranges does the this model cover? Datasheet values for the EJX210B: 1 to 100 kPa (4 to 400 inH2O); 5 to 500 kPa (20 to 2000 inH2O). What accuracy and output does the EJX210B provide? For the EJX210B the datasheet gives plus or minus 0.075% of span. Output and communication: ISA100.11a.

Documents and quotation

The manufacturer datasheet for the EJX210B is attached to this page and gives the complete model and suffix codes, dimensions and options. To receive a quotation, send the RFQ with the part number EJX210B, the quantity and your required range and approvals, and the Seven Star LLC team will reply with availability and delivery information for Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Yokogawa EJX210B Wireless flange mounted dp transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX210B Wireless flange mounted dp

Answers from our engineering team on installation, compatibility and integration.

01What is the Yokogawa EJX210B?
The Yokogawa EJX210B is a wireless flange mounted differential pressure transmitter. The EJX210B is a wireless flange mounted differential pressure transmitter for tank level and density measurement.
02What measuring ranges does the EJX210B cover?
Datasheet values for the EJX210B: 1 to 100 kPa (4 to 400 inH2O); 5 to 500 kPa (20 to 2000 inH2O).
03What accuracy and output does the EJX210B provide?
For the EJX210B the datasheet gives plus or minus 0.075% of span. Output and communication: ISA100.11a.
04What network does the EJX210B use?
The EJX210B uses the ISA100.11a wireless protocol in the 2.4 GHz band, with AES 128 bit security, and it must be commissioned through an ISA100.11a gateway.
05How can I request a quotation for the EJX210B in Oman?
Send an RFQ with the part number EJX210B, quantity, range, output and approvals through the inquiry form. Seven Star LLC replies with availability and delivery for Oman and the GCC, and the datasheet is on the product page.