Brand:

Yokogawa EJX120A Draft Range Differential Pressure Transmitter

Description

Yokogawa EJX120A Draft Range Differential Pressure Transmitter: overview

The Yokogawa EJX120A is the high-performance draft-range differential pressure transmitter of the EJX-A line. It resolves spans as small as 0.025 kPa, which puts it in the territory of furnace draft, ventilation and low-pressure air duct measurement, and it brings the EJX diagnostics to that duty.

Seven Star LLC lists the Yokogawa EJX120A for engineers, maintenance planners and procurement teams in Oman and across the GCC who need to replace an installed unit, extend a loop or specify a new instrument for an oil and gas, utility, water or manufacturing project. The page below summarizes the key facts from the manufacturer datasheet so that a first technical review can be done before the full document is opened.

Key features of the EJX120A

  • EJX120A uses a single crystal silicon resonant sensor.
  • Stated reference accuracy: plus or minus 0.09% of span (span at or above 0.4 kpa).
  • Fast response with damping adjustable from 0.00 to 100.00 s, and a 10-segment signal characterizer for the analog output.
  • Integral LCD indicator option with 5-digit display, bar graph and local parameter setting through the external zero adjustment screw.
  • EJX multi-sensing diagnostics detect problems such as impulse line blockage or heat trace breakage, with an optional status output.
  • Cast aluminum housing as standard with IP66/IP67 and Type 4X protection, and stainless steel housing as an option.
  • SIL 2 capability for the standard HART type, so the EJX120A can be used in safety instrumented functions after the usual proof-test planning.

EJX120A technical specifications

A single capsule, code E, handles spans from 0.025 to 1 kPa with a calibrated range of -1 to 1 kPa. For square root output the minimum span is 0.1 kPa. As with other draft-range instruments, the allowable working pressure is only -50 to 50 kPa and the process and ambient temperature limits are -25 to 80 C, so check these against the actual site conditions.

The reference accuracy of plus or minus 0.09% of span is stated for spans at or above 0.4 kPa, with a response time of 150 ms.

Tilting the transmitter by up to 90 degrees causes a small zero shift that is removed with the zero adjustment, so mounting position is not critical once the transmitter is zeroed in place.

The table lists the main values stated in the datasheet for this model. Values depend on the selected capsule, wetted material and options, so always confirm the final model code with the datasheet before ordering.

Parameter Value
Type Draft range differential pressure transmitter
Span (capsule E) 0.025 to 1 kPa (0.1 to 1 kPa for square root output); 0.1 to 4 inH2O
Range -1 to 1 kPa (-4 to 4 inH2O)
Reference accuracy Plus or minus 0.09% of span (span at or above 0.4 kPa)
Stability Plus or minus 0.15% of URL per year
Ambient temperature effect Plus or minus (0.1% span + 0.15% URL) per 28 C change
Maximum working pressure -50 to 50 kPa (-7.25 to 7.25 psi)
Ambient temperature -25 to 80 C
Process temperature -25 to 80 C
Response time 150 ms (damping at zero, including 45 ms dead time)
Output 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered
Diagnostics Multi-sensing diagnostics; optional status output for pressure high and low alarm
Wetted parts, code S Cover flange and process connector ASTM CF-8M, Hastelloy C-276 diaphragm, PTFE gasket, 316 SST vent plug
Weight 3.7 kg without indicator, bracket and process connector

Typical applications in Oman and the GCC

  • Oil and gas. Upstream and midstream facilities use the EJX120A for boiler and furnace draft, ventilation and cleanroom pressure cascades, fan and duct differential pressure, and low-pressure tank blanketing, where a stable digital signal and fast response help the control system and the safety layer.
  • Utilities and power. In power and utility plants across the GCC the EJX120A supports steam, feedwater, fuel gas and cooling circuits, and its diagnostics reduce unplanned inspection walks in hot plant areas.
  • Water and desalination. Desalination and water treatment plants rely on pressure and differential pressure points for pump protection and membrane skid monitoring, and a EJX120A fits those duties with materials chosen for the water chemistry.
  • Manufacturing and process. Petrochemical, fertilizer, food and general manufacturing units in Oman use the EJX120A on reactors, filters, compressors and storage, where HART or fieldbus communication feeds asset-management software.

Selection and compatibility notes

Start the selection of a EJX120A from the measured variable and the calibrated span, then pick the capsule whose upper range limit leaves comfortable margin. The datasheet shows that accuracy is quoted for spans at or above a capsule-specific value and carries an extra term for narrower spans, so very high rangedown should be checked against the formula rather than assumed.

Check the wetted materials against the process and the cleaning or flushing chemicals. Material code S with a Hastelloy C-276 diaphragm is the typical starting point, and other materials can be selected through the model code. The datasheet warns that an unsuitable material can leak process fluid or damage the diaphragm, so the choice must be made with the process conditions in hand.

Output and protocol should follow the control system. A 4 to 20 mA signal with digital communication is standard, and Fieldbus and PROFIBUS PA types have separate datasheets. For hazardous areas, review the approval options listed in the datasheet, such as FM, ATEX, CSA and IECEx, and confirm that the certificate on the nameplate matches the zone and gas group of the installation.

Installation and commissioning of the EJX120A

Mount the EJX120A on a rigid bracket or directly on a manifold, with the process connections oriented to suit the impulse line slope. Use a three-valve or five-valve manifold so that the transmitter can be isolated, equalized and zeroed without breaking process connections. For gas service, mount above the tapping points; for liquids, mount below, and keep both impulse lines at the same temperature to avoid false differential readings.

After mounting, apply the electrical connection through the conduit entry, ground the housing, and power the loop. Perform a loop test and set the zero with the process isolated or the impulse lines equalized. Range the EJX120A either with a HART or BRAIN communicator or locally through the zero adjustment screw. Document the tag, range and damping in the commissioning record.

Maintenance and calibration

The EJX120A needs little routine maintenance. Check zero and span against a reference standard at an interval set by your calibration policy, inspect impulse lines and vent or drain plugs for blockage and leakage, and review the diagnostics reported by the transmitter. Keep the housing covers tight with intact O-rings, because the enclosure rating depends on them. Spare indicator and amplifier units can be changed in the field without touching the process.

Related products and ordering notes for the EJX120A

Other Yokogawa models in the same product area include EJX110A, EJX130A, EJX115A and EJA120E, which may suit neighboring points on the same plant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify compatible equipment.

When you ask for a quotation, state the exact model code, the measuring range, the output type, any hazardous area approval and the quantity. A complete code lets us confirm that the unit matches the installed unit or the project specification, and it avoids delays caused by option mismatches.

Frequently asked questions in short

What is the Yokogawa this model? The Yokogawa this model is a draft-range differential pressure transmitter. The this model is the high-performance draft-range differential pressure transmitter of the EJX-A line. What measuring ranges does the this model cover? Datasheet values for the EJX120A: 0.025 to 1 kPa (0.1 to 1 kPa for square root output); 0.1 to 4 inH2O. What accuracy and output does the EJX120A provide? For the EJX120A the datasheet gives plus or minus 0.09% of span (span at or above 0.4 kpa). Output and communication: 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered.

Documents and quotation

The manufacturer datasheet for the EJX120A is attached to this page and gives the complete model and suffix codes, dimensions and options. To receive a quotation, send the RFQ with the part number EJX120A, the quantity and your required range and approvals, and the Seven Star LLC team will reply with availability and delivery information for Oman and the GCC.

Other Models in the Yokogawa Draft Range

Seven Star LLC supplies models from the Yokogawa Draft range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJA120E Draft Range Differential Pressure TransmitterPressure TransmittersView details
Yokogawa EJX120A Draft Range Differential Pressure TransmitterPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa EJX120A Draft Range Differential Pressure Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX120A Draft Range Differential Pressure

Answers from our engineering team on installation, compatibility and integration.

01What is the Yokogawa EJX120A?
The Yokogawa EJX120A is a draft-range differential pressure transmitter. The EJX120A is the high-performance draft-range differential pressure transmitter of the EJX-A line.
02What measuring ranges does the EJX120A cover?
Datasheet values for the EJX120A: 0.025 to 1 kPa (0.1 to 1 kPa for square root output); 0.1 to 4 inH2O.
03What accuracy and output does the EJX120A provide?
For the EJX120A the datasheet gives plus or minus 0.09% of span (span at or above 0.4 kpa). Output and communication: 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered.
04Which accessories are normally used with the EJX120A?
The EJX120A is normally installed with a three-valve or five-valve manifold, impulse piping and a mounting bracket, plus a HART communicator or configuration software for ranging and diagnostics.
05How can I request a quotation for the EJX120A in Oman?
Send an RFQ with the part number EJX120A, quantity, range, output and approvals through the inquiry form. Seven Star LLC replies with availability and delivery for Oman and the GCC, and the datasheet is on the product page.