Brand:

Omron G2R-1-S SPDT 10 A Slim Plug-In Power Relay

Description

G2R-1-S: slim single-pole 10 A plug-in relay

The Omron G2R-1-S is a slim general-purpose plug-in power relay with one changeover contact rated 10 A. It carries a built-in mechanical operation indicator and a nameplate, and fits 5-pin sockets, including the Push-In Plus P2RF-05-PU. Seven Star LLC supplies the G2R-1-S in Oman and the GCC as an independent supplier in Muscat. This page decodes the part number and lists the points to confirm when ordering.

  • G2R is the slim power relay series.
  • 1 means one pole (SPDT).
  • S means plug-in terminals.
  • No further letter means the general-purpose version without LED or diode.
  • The ordering code adds the rated coil voltage and (S), for example G2R-1-S 12 VDC (S).

The 1-pole body is only about 20 g, yet it switches 10 A, which is why it is a frequent first choice for load switching in compact control cabinets.

G2R-1-S technical specifications

Parameter Specification
Manufacturer / part number Omron G2R-1-S (ordering code adds rated coil voltage and (S))
Poles / contact form 1 pole, SPDT
Rated load, resistive 10 A at 250 VAC; 10 A at 30 VDC
Rated load, inductive 7.5 A at 250 VAC (cos phi 0.4); 5 A at 30 VDC (L/R 7 ms)
Max. switching voltage / current 440 VAC, 125 VDC / 10 A
Max. switching power 2,500 VA / 300 W resistive
Dielectric strength, coil to contacts 5,000 VAC for 1 min
Release time AC 10 ms max.; DC 5 ms max. (20 ms with diode)
Operate time 15 ms max. (1-pole and 2-pole)
Contact resistance 100 mΩ max.
Contact structure Single, SPDT
Insulation resistance 1,000 MΩ min. at 500 VDC
Mechanical endurance AC coil 10 million operations min.; DC coil 20 million operations min.
Electrical endurance 100,000 operations min. at rated load, 1,800 operations/h
Max. frequency 18,000 operations/h mechanical; 1,800 operations/h under rated load
Operating temperature −40 to 70°C, no icing or condensation
Humidity 5% to 85%
Weight Approx. 20 g

Values are from the Omron G2R-@-S(S) datasheet. Gold-plated contact versions are available on request from the manufacturer for low-level signals; they are not part of this standard model.

How G2R-1-S switches and what the options add

A coil moves an armature to transfer a single changeover contact between its normally closed and normally open positions. With only one pole, the contact gap and spacing are larger than on the 2-pole body, and that is the reason the dielectric strength between coil and contacts reaches 5,000 VAC and the contact rating reaches 10 A.

The G2R-1-S has no LED or diode, so it is the plainest version. The mechanical flag shows contact position, helpful when diagnosing without a meter. The coil can be AC or DC, and AC coil versions run slightly higher power consumption than DC.

Coil data for G2R-1-S

Standard AC coils are 24, 48, 110, 120, 230 and 240 V; DC coils are 6, 12, 24 and 48 V. Data from the datasheet:

AC coil Current 50 Hz / 60 Hz Resistance
24 V 43.5 / 37.4 mA 253 ohm
48 V 21.8 / 18.8 mA 1,040 ohm
110 V 9.5 / 8.2 mA 5,566 ohm
120 V 8.6 / 7.5 mA 7,286 ohm
230 V 4.4 / 3.8 mA 27,172 ohm
240 V 4.2 / 3.7 mA 27,800 ohm
DC coil Rated current Resistance
6 V 87.0 mA 69 ohm
12 V 43.2 mA 278 ohm
24 V 21.6 mA 1,113 ohm
48 V 11.4 mA 4,220 ohm

Must-operate voltage is 80% max. of rated for AC coils and 70% max. for DC coils; must-release voltage is 30% max. for AC and 15% min. for DC. Maximum voltage is 110% of rated. Power consumption is approx. 0.9 VA at 60 Hz for AC and approx. 0.53 W for DC.

Sockets and related parts for G2R-1-S

The G2R-1-S plugs into 5-pin sockets. The Push-In Plus P2RF-05-PU cuts wiring time by about 60% according to Omron measurements, while screw sockets suit conventional panels. The 2-pole equivalent is G2R-2-S on an 8-pin socket. Options with LED (G2R-1-SN), test button (G2R-1-SNI) and diode (G2R-1-SD) share the same footprint.

Socket type 1-pole models
Push-In Plus P2RF-05-PU
Screw, track mount P2RF-05, P2RF-05-E (finger-safe), P2RFZ-05-E
PCB / solder back mount P2R-05P, P2R-057P / P2R-05A

Accessories listed with the series include short bars, label sheets (XW5Z-P4.0LB1 for Push-In Plus and XW5Z-P2.5LB1 for screw sockets), mounting tracks PFP-50N, PFP-100N and PFP-100N2, end plate PFP-M and spacer PFP-S. P2RF-@-E sockets are finger-safe and require forked, not round, crimp terminals.

Selection and ordering checklist for G2R-1-S

Confirm the following before requesting a quotation for G2R-1-S.

  • Decide whether one 10 A pole is enough; if two circuits are needed use G2R-2-S at 5 A per pole.
  • Choose AC or DC coil and the voltage.
  • Check load type: 10 A resistive and 7.5 A inductive at 250 VAC.
  • Decide if LED, diode or test button versions are better for your panel.
  • Choose a socket type: Push-In Plus, screw or PCB.
  • State if gold-plated contacts are needed for dry-circuit signals.

Installation, commissioning and maintenance of G2R-1-S

Plug the G2R-1-S into its socket and ensure the retaining clip or the socket frame holds it. Observe correct coil terminals and confirm the coil voltage marking.

  • Use the mechanical indicator to confirm operation during testing.
  • Keep inductive loads suppressed at the load.
  • Keep spacing between adjacent relays at full load to limit heat.
  • Do not exceed 110% of rated coil voltage.
  • Stock spares by coil voltage, as AC and DC coil relays look alike.

Typical G2R-1-S applications in Oman and the GCC

The G2R-1-S is a workhorse for switching contactor coils, solenoid valves, heaters and lamps from low-power control outputs. In Oman and the GCC it appears in HVAC control panels, pump starters, package unit controls and relay interface modules for PLC outputs.

Where panel temperatures are high the relay is rated for operation up to 70°C, but contact loading should be reduced when running at the limit. Dust ingress should be managed by sealed enclosures.

A few practical habits extend relay life in service. Load the contact below its resistive rating whenever the circuit is inductive, keep the coil voltage close to nominal rather than relying on the wide operating window, and avoid mounting relays directly above heat-producing components. When a panel is modified, record the coil voltage and socket type on the drawing, because replacement relays that look identical but carry a different coil rating are a common source of burnt coils during urgent repairs. Where relays are replaced on a schedule rather than on failure, the date of installation can be written on the nameplate area that the relay body provides, which makes it simple to see at a glance which units have served longest. Ordering a modest overstock of the common coil voltages at the time of the first purchase usually costs less than later urgent freight.

G2R-S family compared with G2R-1-S

The G2R-S range is built from one body with a set of options added through the suffix letters. The table shows the available combinations, with G2R-1-S highlighted by its row.

Suffix Meaning SPDT model DPDT model
(none) General purpose, AC or DC coil G2R-1-S G2R-2-S
N LED indicator G2R-1-SN G2R-2-SN
NI LED indicator with test button G2R-1-SNI G2R-2-SNI
D Built-in diode (DC coils) G2R-1-SD G2R-2-SD
ND LED indicator and diode G2R-1-SND G2R-2-SND
NDI LED, diode and test button G2R-1-SNDI G2R-2-SNDI

Information to send with an RFQ for G2R-1-S

  • Part number G2R-1-S with coil type and voltage.
  • Quantity of relays and sockets.
  • Load voltage and current, resistive or inductive.
  • Socket type.
  • Any request for gold-plated contacts.
  • Delivery location.

Documents and quotation

A datasheet for the G2R-S series is attached on this page, covering the model legend, coil and contact data, approved standards, sockets and precautions for G2R-1-S.

Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer. Send the part number G2R-1-S with the coil voltage and quantity, and we will confirm availability and lead time for Oman and the GCC.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Omron is a Japanese electronics and automation company, founded in 1933 in Osaka by Kazuma Tateisi and now headquartered in Kyoto. Its industrial automation business makes PLCs, I/O, sensors, relays, safety components, motion control and robots. Omron's CJ and NX series controllers and I/O units are widely used in machine building.

Seven Star LLC lists Omron PLC input and output units from the CJ and NX series and supplies them to panel builders and maintenance teams in Oman.

Omron company profile

Founded 1933, Osaka, Japan
Founder Kazuma Tateisi
Headquarters Kyoto, Japan
Business Industrial automation, healthcare, electronic components
Product families CJ1/CJ2 PLCs and I/O units, NX and NJ controllers, NX I/O, E2E proximity sensors, G2R and MY relays

Omron CJ-series and NX-series units listed here

Three I/O units are on this page. The CJ1W-ID211 is a CJ-series 16-point 24 VDC input unit and the CJ1W-OC211 is a CJ-series 16-point relay output unit. The NX-ID5442 is an NX-series 16-point 24 VDC digital input unit for PNP wiring, 12 mm wide with push-in terminals. CJ and NX units belong to different hardware platforms and do not plug into each other's racks.

Omron products we list

Family Examples
PLC & I/O Cards CJ1W-ID211 CJ-Series 16-Point 24 VDC Inp…, CJ1W-OC211 CJ-Series 16-Point Relay Outp…, NX-ID5442 NX-Series 16-Point Digital Inp…

Ordering Omron PLC modules: what we need

Send the complete model number from the front or side label of the unit, including every suffix. If you are replacing a failed card, add the CPU or coupler model it is mounted with, and tell us if the terminal block or connector is needed as well. For obsolete Omron PLC parts we check which successor the manufacturer documents. Requests from other GCC countries are handled the same way.

Facts checked against Omron's published company history, October 2026.

FAQ

Questions about the Omron G2R-1-S SPDT 10 A Slim Plug-In Power Relay

Answers from our engineering team on installation, compatibility and integration.

01What load can G2R-1-S switch?
The single SPDT contact is rated 10 A at 250 VAC or 30 VDC resistive. Inductive ratings are 7.5 A at 250 VAC and 5 A at 30 VDC. Maximum switching voltage is 440 VAC or 125 VDC.
02What coil voltages does G2R-1-S come in?
AC coils of 24, 48, 110, 120, 230 and 240 V and DC coils of 6, 12, 24 and 48 V. The coil voltage is added to the order with the (S) suffix.
03Which sockets fit G2R-1-S?
5-pin sockets such as P2RF-05-PU, P2RF-05, P2RF-05-E, P2RFZ-05-E for front mounting, and P2R-05P, P2R-057P, P2R-05A for back mounting.
04How is G2R-1-S different from G2R-1-SN?
G2R-1-SN adds a LED indicator. The plain G2R-1-S has only the mechanical operation indicator.
05What is the life of G2R-1-S?
Mechanical life is 10 million operations with AC coil and 20 million with DC coil. Electrical life is at least 100,000 operations at rated load.