Brand:

Omron MY2IN-GS DPDT Relay with Latching Lever and LED

Description

MY2IN-GS: 2-pole relay with a latching lever for circuit testing

The Omron MY2IN-GS is a DPDT miniature power relay that adds a manual latching lever to the standard MY2N-GS body. The lever lets a technician force the contacts closed, momentarily or locked, without energising the coil, which is invaluable when proving a relay sequence. Seven Star LLC supplies the MY2IN-GS in Oman and the GCC as an independent supplier in Muscat. Details follow below.

  • MY is the miniature plug-in power relay series.
  • 2 means two poles (DPDT) with an 8-pin footprint.
  • I means a latching lever is fitted.
  • N means a LED operation indicator and built-in mechanical indicators.
  • GS is the series suffix; the datasheet ordering list adds -R and the coil voltage.

The lever colour identifies the coil: red for AC and blue for DC, and the LED is red for AC and green for DC.

MY2IN-GS technical specifications

Parameter Specification
Manufacturer / part number Omron MY2IN-GS (datasheet ordering code MY2IN-GS-R with coil voltage)
Poles / contact form 2 poles, DPDT
Latching lever Yes: slide one step for momentary operation with a yellow button, two steps to lock contacts in operated position
Lever colour Red for AC coil; blue for DC coil
Contact rating, resistive 10 A at 250 VAC; 10 A at 30 VDC
Max. switching capacity 2,500 VA / 300 W
Max. contact voltage 250 VAC, 220 VDC
Coil voltages AC 12, 24, 48, 100/110, 110/120, 200/220, 220/240 V; DC 6, 12, 24, 48, 100/110, 220 V
Operating temperature −40 to 70°C for models with LED
Operate / release time 20 ms max. / 20 ms max.
Contact resistance 100 mΩ max.
Contact material Ag
Insulation resistance 1,000 MΩ min.
Dielectric strength 2,000 VAC coil to contacts; 2,000 VAC between different poles; 1,000 VAC same pole
Mechanical endurance 50,000,000 operations
Max. frequency 18,000 operations/h mechanical; 2,400 operations/h at rated load
Minimum load (reference) 1 mA at 5 VDC
Humidity 5% to 85%
Weight Approx. 35 g

Specifications follow the MY-GS datasheet. The lever should be operated with an insulated tool, as the datasheet describes pressing the yellow button for momentary operation.

How MY2IN-GS works and what the indicators show

The relay works like any plug-in electromechanical relay: coil current moves an armature that changes the contact state. The addition of a lever offers two manual positions. Slid one step, the lever exposes a yellow button which can be pressed to operate the contacts temporarily; slid two steps, the contacts lock in the operated position.

This design helps commissioning teams: instead of forcing signals or jumpering coil circuits, they can operate the relay by hand and observe the effect on the rest of the circuit. Care is needed, as a locked lever leaves the circuit energised regardless of the coil, so a locked relay should be recorded and released before handover.

Coil ratings for MY2IN-GS

Coil options for MY2IN-GS match those of the MY2N-GS. Choose the type that matches the control supply, and note that lever and LED colours depend on the coil type.

AC coil data from the datasheet (rated current measured at 23°C):

Rated voltage (AC) Current 50 Hz / 60 Hz (mA) Coil resistance (ohm)
12 V 106.5 / 91 46
24 V 53.8 / 46 180
48 V 25.7 / 21.1 788
100/110 V 11.7/12.9 / 10.0/11.0 3,750
110/120 V 9.9/10.8 / 8.4/9.2 4,430
200/220 V 6.2/6.8 / 5.3/5.8 12,950
220/240 V 5.2/6.2 / 4.3/5.0 15,920

DC coil data from the datasheet (values in brackets are for models with LED indicators):

Rated voltage (DC) Rated current (mA) Coil resistance (ohm)
6 V 146 (151 with LED) 41.0 (39.8)
12 V 72.7 (75) 165 (160)
24 V 36.3 (37.7) 662 (636)
48 V 17.6 (18.8) 2,725 (2,560)
100/110 V 8.7 (9.0) / 9.6 (9.9) 11,440 (11,100)
220 V 3.6 60,394

Must-operate voltage is 80% of rated voltage maximum for AC coils (30% minimum must-release) and the same 80% maximum for DC coils with 10% minimum must-release. Maximum voltage is 110% of rated. For specified characteristics, apply the rated voltage to the coil.

Sockets and related parts for MY2IN-GS

MY2IN-GS fits the same 8-pin sockets as other MY2 types. When used with a PCB-terminal socket such as PY08-02, the datasheet notes that a PYC-P mounting bracket should be checked for compatibility. It is the right relay where test access matters; for fixed circuits the cheaper MY2N-GS is enough.

Mounting 8-pin (MY2 types)
Front, finger-safe PYFZ-08-E, PYF08A-N
Front, Push-In Plus PYF-08-PU
Back, PCB PY08-02

Sockets are ordered separately. The datasheet also mentions the PYC-A1 and PYC-P retaining parts for joining socket and relay, and notes that a relay with a latching lever and a PCB-terminal socket need the PYC-P mounting bracket to be checked first.

Selection and ordering checklist for MY2IN-GS

Settle the following before requesting a quotation for MY2IN-GS.

  • Confirm that a manual test lever is wanted and that site rules allow it on that circuit.
  • Choose AC or DC coil and the voltage.
  • Check load against 10 A at 250 VAC and inductive ratings.
  • Select an 8-pin socket, noting PCB socket restrictions with the lever.
  • Decide on diode or CR suppression versions if required (MY2IN-D1/D2-GS or MY2IN-CR-GS).
  • Plan a procedure to ensure levers are returned to normal after testing.

Installation, commissioning and maintenance of MY2IN-GS

Install the MY2IN-GS as for any MY2 relay. Do not leave the lever in the locked state after testing.

  • Use an insulated tool to press the yellow button.
  • Record any relay left locked on purpose.
  • Check coil voltage matches the colour code on the lever.
  • Verify contact motion with the mechanical indicator.
  • Keep a few spares since test levers can be mishandled during frequent testing.

Typical MY2IN-GS applications in Oman and the GCC

Latching-lever relays are favoured in shutdown and interlock panels where sequences must be proven without live plant: pump auto-start logic, burner management repeats, MCC control circuits and gas-turbine auxiliary panels. In Oman and the GCC they appear in plant maintenance specifications that demand testability.

In regions where plant turnaround time is expensive, the ability to prove circuits quickly pays back. The lever must nevertheless be controlled by permit-to-work practice.

MY-GS family compared with MY2IN-GS

The MY-GS series covers several versions of the same relay body. This table shows where MY2IN-GS sits among them.

Model Poles Extras Coil types
MY2-GS 2 (DPDT) Mechanical indicator only AC and DC
MY2N-GS 2 (DPDT) LED + mechanical indicator AC and DC
MY2IN-GS 2 (DPDT) LED, indicator and latching lever AC and DC
MY2N-D1/D2-GS 2 (DPDT) LED, built-in diode (polarity 13+ or 14+) DC
MY2N-CR-GS 2 (DPDT) LED, built-in CR circuit AC 100 V and above
MY4N-GS / MY4IN-GS 4 (4PDT) LED; latching lever on IN AC and DC

Information to send with an RFQ for MY2IN-GS

  • Part number MY2IN-GS, coil type and voltage.
  • Quantity of relays and sockets.
  • Load details.
  • Whether surge protection variants are wanted.
  • Socket mounting.
  • Delivery location.

Documents and quotation

A datasheet for the MY-GS series is attached on this page with the model legend, coil data, contact ratings, certified ratings, socket list and precautions relevant to MY2IN-GS.

Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer. Send the part number MY2IN-GS with the coil voltage and quantity, and we will confirm availability and lead time for Oman and the GCC.

Other Models in the Omron My Gs Relays Range

Seven Star LLC supplies models from the Omron My Gs Relays range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Omron MY2N-GS DPDT Miniature Power Relay with LEDAutomation AccessoriesView details
Omron MY4N-GS 4PDT Miniature Power Relay with LEDAutomation AccessoriesView details
Omron MY2IN-GS DPDT Relay with Latching Lever and LEDAutomation AccessoriesYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Omron is a Japanese electronics and automation company, founded in 1933 in Osaka by Kazuma Tateisi and now headquartered in Kyoto. Its industrial automation business makes PLCs, I/O, sensors, relays, safety components, motion control and robots. Omron's CJ and NX series controllers and I/O units are widely used in machine building.

Seven Star LLC lists Omron PLC input and output units from the CJ and NX series and supplies them to panel builders and maintenance teams in Oman.

Omron company profile

Founded 1933, Osaka, Japan
Founder Kazuma Tateisi
Headquarters Kyoto, Japan
Business Industrial automation, healthcare, electronic components
Product families CJ1/CJ2 PLCs and I/O units, NX and NJ controllers, NX I/O, E2E proximity sensors, G2R and MY relays

Omron CJ-series and NX-series units listed here

Three I/O units are on this page. The CJ1W-ID211 is a CJ-series 16-point 24 VDC input unit and the CJ1W-OC211 is a CJ-series 16-point relay output unit. The NX-ID5442 is an NX-series 16-point 24 VDC digital input unit for PNP wiring, 12 mm wide with push-in terminals. CJ and NX units belong to different hardware platforms and do not plug into each other's racks.

Omron products we list

Family Examples
PLC & I/O Cards CJ1W-ID211 CJ-Series 16-Point 24 VDC Inp…, CJ1W-OC211 CJ-Series 16-Point Relay Outp…, NX-ID5442 NX-Series 16-Point Digital Inp…

Ordering Omron PLC modules: what we need

Send the complete model number from the front or side label of the unit, including every suffix. If you are replacing a failed card, add the CPU or coupler model it is mounted with, and tell us if the terminal block or connector is needed as well. For obsolete Omron PLC parts we check which successor the manufacturer documents. Requests from other GCC countries are handled the same way.

Facts checked against Omron's published company history, October 2026.

FAQ

Questions about the Omron MY2IN-GS DPDT Relay with Latching Lever and

Answers from our engineering team on installation, compatibility and integration.

01What does the latching lever on MY2IN-GS do?
It lets the contacts be operated by hand. One step gives momentary operation with a yellow button; two steps lock the contacts in the operated position.
02How can I tell AC and DC MY2IN-GS apart?
The latching lever is red for an AC coil and blue for a DC coil. The LED is red for AC and green for DC.
03What contact rating does MY2IN-GS have?
10 A at 250 VAC or 30 VDC resistive per pole, with two poles. Maximum contact voltage is 250 VAC or 220 VDC.
04Can MY2IN-GS go into PCB sockets?
Yes with caution. The datasheet notes a combination of the latching-lever relay with PY08-02 and a PYC-P mounting bracket needs checking.
05Is MY2IN-GS the same size as MY2N-GS?
The body and pin layout are the same 8-pin design, so sockets are shared, though the lever adds a protrusion that affects PCB socket combinations.