Schneider Electric LADN31 TeSys D 3 NO + 1 NC Contact Block

Description

LADN31: three NO and one NC contacts in a four-contact TeSys D block

The LADN31 is a Schneider Electric TeSys D front auxiliary contact block with three normally open and one normally closed contact. It is for contactors that report to several systems and need only one interlock. Seven Star LLC supplies the LADN31 in Oman and the GCC as an independent supplier based in Muscat.

The 31 reads three NO, one NC. The datasheet lists protection as IP2X where the other group members state IP20; the practical meaning is the same, finger-safe terminals, but the wording is worth noting when specifying.

Technical specifications of the LADN31

Parameter Specification
Manufacturer / part number Schneider Electric / LADN31
Description Product datasheet Auxiliary contact block, TeSys D, 3NO + 1NC, front mounting, screw clamp terminals
Range TeSys; TeSys Deca
Product name TeSys Deca
Product or component type Auxiliary contact block
Device short name LADN
Range compatibility TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D
Mounting location Front
Pole contact composition 3 NO + 1 NC
Contacts operation Instantaneous
[Ue] rated operational voltage 690 V AC 25 to 400 Hz
[Ie] rated operational current 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA
[Ith] conventional free air thermal 10 A (at 60 °C)
Standards EN/IEC 60947-5-1; GB/T 14048.5; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certifications CB Scheme; UL; CSA; CCC; EAC; UKCA
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1
Permissible short-time rating 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms; are subject to change – check with your local distributor.
Protection type GG fuse 10 A
Mechanical durability 30 Mcycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections – terminals Screw clamp terminals 1 cable(s) 1 to 4 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1 to 4 mm²flexible without cable end
Height 48 mm
Width 44 mm
Depth 42 mm
Net weight 0.05 kg
Environmental characteristic Normal environment
IP degree of protection IP2X conforming to IEC 60529
Ambient air temperature (operation, as listed) -5 to 60 °C
Operating altitude 3000 m

Ordering the LADN31

  • 3 NO + 1 NC contact pattern.
  • Family compatibility as listed for LADN contact blocks.
  • 44 mm width to be free on the contactor front.
  • Check where the single NC contact is used for interlocking.
  • Alternative patterns: LADN22 and LADN40.

When 3 NO + 1 NC on the LADN31 fits the scheme

Count the signals the contactor has to give: one self-hold, one lamp, one PLC input, and one interlock. That is three closing contacts and one opening contact, exactly the LADN31 pattern.

Where a second interlock is needed, move up to a LADN22 and give up one of the closing contacts.

Ratings and compatibility of the LADN31

Rated operational voltage is 690 V AC at 25 to 400 Hz, with conventional thermal current of 10 A at 60 °C. Rated operational current is 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13 and 0.1 A at 600 V DC-13. Making capacity is 140 A AC and 250 A DC, protection is a 10 A gG fuse, mechanical durability is 30 Mcycles, and the minimum switching level is 5 mA at 17 V. The non-overlap time between the NC and NO contacts is 1.5 ms on energisation and on de-energisation.

The block is 44 mm wide, 48 mm high and 42 mm deep and mounts on TeSys D and TeSys F contactors as listed in the datasheet. Environmental limits are -5 to 60 °C and 3000 m.

LADN31 uses in Oman and the GCC

Process pumps, compressor starters and crane drives have status, alarm and permissive signals taken from the main contactor. The three closing contacts go to the PLC, a local lamp and a remote indication, while the opening contact interlocks the opposite direction.

In hot panel rooms, keep the block clear of heat sources and ventilated.

LADN family: the LADN31 compared with its siblings

All six references below are front-mounting TeSys D blocks with screw clamp terminals; they differ in contact pattern and width.

Reference Contacts Width Protection
LADN11 1 NO + 1 NC 26 mm IP20 conforming to IEC 60529
LADN11G 1 NO + 1 NC 26 mm IP20 conforming to IEC 60529
LADN20 2 NO 26 mm IP20 conforming to IEC 60529
LADN22 2 NO + 2 NC 44 mm IP20 conforming to IEC 60529
LADN31 3 NO + 1 NC 44 mm IP2X conforming to IEC 60529
LADN40 4 NO 44 mm IP2X conforming to IEC 60529

LADN31 installation and test

Seat the block on the front, tighten each terminal at 1.7 N.m and test the four contacts under both states of the contactor.

Add a clear label on the cabinet door drawing for the single NC contact, since a three-to-one split is easy to misread.

Information to send with an RFQ for the LADN31

  • Full reference and quantity required
  • Contactor model the block mounts on
  • Contact arrangement needed (NO and NC count)
  • Control voltage and load of each circuit
  • Delivery location and timing

Storage, handling and spares for the LADN31

Keep the LADN31 in its original packaging in a dry, dust-free store until installation, and check the label against the order before fitting. For plants that run continuously, holding one spare unit on site shortens downtime if a replacement is needed during a shutdown or after a fault. Record the reference and installation date in the maintenance log so the next order can be placed quickly.

Documents and quotation

A datasheet for the LADN31 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.

Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Tesys D Ladn Range

Seven Star LLC supplies models from the Se Tesys D Ladn range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LADN11 TeSys D 1 NO + 1 NC Contact BlockContactors & Overload RelaysView details
Schneider Electric LADN11G TeSys D 1 NO + 1 NC EN 50012 BlockContactors & Overload RelaysView details
Schneider Electric LADN20 TeSys D 2 NO Front Contact BlockContactors & Overload RelaysView details
Schneider Electric LADN22 TeSys D 2 NO + 2 NC Contact BlockContactors & Overload RelaysView details
Schneider Electric LADN31 TeSys D 3 NO + 1 NC Contact BlockContactors & Overload RelaysYou are viewing this model
Schneider Electric LADN40 TeSys D 4 NO Front Contact BlockContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric LADN31 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LADN31 TeSys D 3 NO + 1 NC

Answers from our engineering team on installation, compatibility and integration.

01What contacts does the LADN31 have?
Three normally open and one normally closed.
02What protection class does the datasheet give?
IP2X according to IEC 60529. See the datasheet linked on this page for the full figures.
03What width does the LADN31 need?
44 mm. See the datasheet linked on this page for the full figures.
04What mechanical durability is stated?
30 Mcycles. See the datasheet linked on this page for the full figures.
05Which contactor families does the LADN31 fit?
TeSys D and TeSys Deca LC1D and CAD, and TeSys F LC1F and CR1F.