Description
METSEPM2230 an EasyLogic PM2230 class 0.5S panel power meter
The METSEPM2230 is a Schneider Electric product listed in the datasheet as: EasyLogic PM2230, Power & Energy meter, up to the 31st harmonic, LCD display, RS485, class 0.5S. The METSEPM2230 is the higher-accuracy EasyLogic PM2200 meter, with class 0.5S active energy accuracy and harmonics up to the 31st, in a 96 x 96 mm panel housing with RS485. It is chosen when the data feeds energy billing or power quality assessment. Seven Star LLC supplies the METSEPM2230 in Oman and the GCC as an independent supplier based in Muscat.
Decoding the reference: PM2230 is the class 0.5S, 31st-harmonic model of EasyLogic PM2200 according to the datasheet title.
Technical specifications of the METSEPM2230
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / METSEPM2230 |
| Description | EasyLogic PM2230, Power & Energy meter, up to the 31st harmonic, LCD display, RS485, class 0.5S |
| Range | EasyLogic |
| Product name | EasyLogic PM2200 |
| Product or Component Type | Power meter |
| Device short name | PM2230 |
| Device Application | Power monitoring; Sub billing |
| Power quality analysis | total harmonic distortion up to the 31st harmonic |
| Type of measurement | Apparent power min/max, total; Active and reactive power min/max, total; Current min/max, avg; Voltage min/max, avg; Frequency min/max, avg |
| Metering type | Calculated neutral current; Active power P, P1, P2, P3; Current I, I1, I2, I3; Peak demand power PM, QM, SM |
| Accuracy class | Class 1 reactive energy IEC 62053-24; Class 0.5S active energy IEC 62053-22; Class 5 harmonic distortion (I THD & U THD) |
| Measurement accuracy | Apparent power ± 0.5 %; Active energy ± 0.5 %; Reactive energy ± 1 %; Active power ± 0.5 %; Voltage ± 0.5 %; Power factor ± 0.01 |
| Measurement current | 5 to 6000 mA |
| Measurement voltage | 35 to 480 V AC 50/60 Hz between phases; 20 to 277 V AC 50/60 Hz between phase and neutral; 480 to 999000 V AC 50/60 Hz with external VT |
| Frequency measurement range | 45 to 65 Hz |
| [Us] rated supply voltage | 80 to 277 V AC 45 to 65 Hz ± 10 %; 100 to 277 V DC ± 10 % |
| Network Frequency | 60 Hz; 50 Hz |
| Ride-through time | 50 ms 120 V AC typical; 50 ms 230 V AC typical; 50 ms 125 V DC typical |
| Line Rated Current | 5A; 1A |
| Maximum power consumption in | 3.3 W power lines (AC) |
| W | 3.3 W 277 V power lines (DC) |
| input impedance | Current (impedance <= 0.3 mOhm); Voltage (impedance > 5 MOhm) |
| Tamperproof of settings | Protected by access code |
| Display Type | Backlit LCD |
| Display colour | Monochrome |
| Display Resolution | 128 x 128 pixels |
| Demand intervals | Configurable from 1 to 60 min |
| Information displayed | Demand current past value; Demand current present value; Demand power past value; Demand power present value; Voltage; Current; Frequency |
| Control type | 4 x button |
| Local signalling | Red LED output signal 1 to 9999000 pulse/ k_h (kWh, kVAh, kVARh); Green LED module operation and integrated communication |
| Number of inputs | 0 |
| Number of Outputs | 0 |
| Communication port protocol | Modbus RTU 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires; 2500 V |
| Communication port support | Screw terminal block RS485 |
| Data recording | Energy consumption logs; Power logs; Time stamping; Min/max for 8 parameters |
| Function Available | Real time clock |
| Sampling rate | 64 samples/cycle |
| Cybersecurity | Enable/disable communication ports |
| Communication Service | Remote monitoring |
| User Language | Russian; French; Portuguese; English; Spanish; Chinese; German |
| Product certifications | CE conforming to IEC 61010-1; CULus conforming to UL 61010-1; CULus conforming to CSA C22.2 No 61010-1; RCM; EAC; C-tick |
| Mounting Mode | Clip-on |
Accuracy and data of the METSEPM2230
Supply voltage: 80 to 277 V AC 45 to 65 Hz ± 10 %; 100 to 277 V DC ± 10 %. Network frequency: 60 Hz; 50 Hz. Communication protocols: Modbus RTU 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires; 2500 V. Display: Backlit LCD. Resolution: 128 x 128 pixels.
The datasheet lists class 0.5S active energy (IEC 62053-22) and class 1 reactive energy (IEC 62053-24), with class 5 for harmonic distortion. It logs energy consumption and power with time stamps and min/max for eight parameters.
The front is IP54 with an IP30 body, the housing is 96 x 96 mm and 300 g, and the meter mounts by clip. Operating temperature is -10 to 60 degrees Celsius.
Where the METSEPM2230 fits in a metering scheme
In a typical scheme the PM2230 is used at the incomer or major feeder, while PM2220 meters monitor smaller loads. Having the same family simplifies commissioning and spares.
RS485 Modbus RTU integrates the meter into SCADA or building systems, with settings 4800 to 38400 bps listed. There are no digital inputs or outputs on this variant.
Selection checklist for the METSEPM2230
- Billing or analysis need: class 0.5S.
- Harmonics: up to the 31st.
- Panel cut-out: 96 x 96 mm.
- Communication: RS485 address and baud rate.
- CT ratio and VT ratio.
- Operating temperature: -10 to 60 degrees Celsius.
Commissioning the METSEPM2230
Wire per the diagram, apply power and enter the measurement setup. Verify the sign of active power with a known load direction, and the phase order with a phase-rotation meter.
Compare energy with a reference meter over a defined period. Document the CT ratio and wiring, and protect settings by changing the access code.
Typical applications of the METSEPM2230 in Oman and the GCC
In Oman and the GCC, class 0.5S meters are used for internal billing between tenants and process areas, and for power quality checks at plant incomers where harmonics from drives are a concern.
Dimensions, environment and approvals of the METSEPM2230
For the METSEPM2230, plan the mounting space from the datasheet: 96 mm (W) x 96 mm (H) x Total : 76.09 mm; Embedded : 61.64 mm (D). The METSEPM2230 weighs 300 g. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -10 to 60 °C. Relative humidity: 5 to 95 % 50 °C. Ingress protection: IP54 front: conforming to IEC 60529; IP30 body: conforming to IEC 60529. Operating altitude: <= 2000 m. Certifications listed for this reference: CE conforming to IEC 61010-1; CULus conforming to UL 61010-1; CULus conforming to CSA C22.2 No 61010-1; RCM; EAC; C-tick.
Information to send with an RFQ for the METSEPM2230
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Other Models in the Se Pm2200 Range
Seven Star LLC supplies models from the Se Pm2200 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric METSEPM2220 EasyLogic PM2220 Power and | Power Meters & Power Quality | View details |
| Schneider Electric METSEPM2230 EasyLogic PM2230 Power and | Power Meters & Power Quality | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric METSEPM2230 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric METSEPM2230 EasyLogic PM2230
Answers from our engineering team on installation, compatibility and integration.
01What accuracy class does the METSEPM2230 have?
The datasheet gives Class 1 reactive energy IEC 62053-24; Class 0.5S active energy IEC 62053-22; Class 5 harmonic distortion (I THD & U THD).
02What is the front protection of the METSEPM2230?
The datasheet gives IP54 front: conforming to IEC 60529; IP30 body: conforming to IEC 60529.
03What is the weight of the METSEPM2230?
The datasheet gives 300 g.
04What display does the METSEPM2230 have?
The datasheet gives Backlit LCD.
05What is the net weight of the METSEPM2230?
The datasheet gives 300 g.