Schneider Electric METSEPM2220 EasyLogic PM2220 Power and

Description

METSEPM2220 an EasyLogic PM2220 class 1 panel power meter

The METSEPM2220 is a Schneider Electric product listed in the datasheet as: EasyLogic PM2220, Power & Energy meter, up to the 15th harmonic, LCD display, RS485, class 1. The METSEPM2220 is an EasyLogic PM2200 series power and energy meter in a 96 x 96 mm panel format, with class 1 energy accuracy, THD up to the 15th harmonic and RS485 Modbus. It is a cost-effective choice for panels where basic power monitoring and sub-billing are needed. Seven Star LLC supplies the METSEPM2220 in Oman and the GCC as an independent supplier based in Muscat.

Decoding the reference: PM2220 is the class 1 model of EasyLogic PM2200 with harmonics to the 15th. The PM2230 beside it is class 0.5S with harmonics to the 31st.

Technical specifications of the METSEPM2220

Parameter Specification
Manufacturer / part number Schneider Electric / METSEPM2220
Description EasyLogic PM2220, Power & Energy meter, up to the 15th harmonic, LCD display, RS485, class 1
Range EasyLogic
Product name EasyLogic PM2200
Product or Component Type Power meter
Device short name PM2220
Device Application Power monitoring; Sub billing
Power quality analysis total harmonic distortion up to the 15th harmonic
Type of measurement Apparent power min/max, total; Active and reactive power min/max, total; Current min/max, avg; Voltage min/max, avg; Frequency min/max, avg
Metering type Active, reactive, apparent energy (signed, four quadrant); Current I, I1, I2, I3; Peak demand currents; Peak demand power PM, QM, SM
Accuracy class Class 1 active energy IEC 62053-21; Class 1 reactive energy IEC 62053-24; Class 5 harmonic distortion (I THD & U THD)
Measurement accuracy Apparent power ± 1 %; Active energy ± 1 %; Reactive energy ± 1 %; Active power ± 1 %; Voltage ± 0.5 %; Power factor ± 0.01
Measurement current 5 to 6000 mA
Measurement voltage 35 to 480 V AC 50/60 Hz between phases; 20 to 277 V AC 50/60 Hz between phase and neutral; 480 to 999000 V AC 50/60 Hz with external VT
Frequency measurement range 45 to 65 Hz
[Us] rated supply voltage 44 to 277 V AC 45 to 65 Hz ± 10 %; 44 to 277 V DC ± 10 %
Network Frequency 50 Hz; 60 Hz
Ride-through time 100 ms 120 V AC typical; 400 ms 230 V AC typical; 50 ms 125 V DC typical
Line Rated Current 1A; 5A
Maximum power consumption in 3.3 W power lines (AC)
W 2 W 277 V power lines (DC)
input impedance Current (impedance <= 0.3 mOhm); Voltage (impedance > 5 MOhm)
Tamperproof of settings Protected by access code
Display Type Backlit LCD
Display colour Monochrome
Display Resolution 128 x 128 pixels
Demand intervals Configurable from 1 to 60 min
Information displayed Demand current past value; Demand current present value; Demand power past value; Demand power present value; Voltage; Current; Frequency
Control type 4 x button
Local signalling Red LED output signal 1 to 9999000 pulse/ k_h (kWh, kVAh, kVARh); Green LED module operation and integrated communication
Number of inputs 0
Number of Outputs 0
Communication port protocol Modbus RTU 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires; 2500 V
Communication port support Screw terminal block RS485
Data recording Time stamping; Min/max for 8 parameters
Function Available Real time clock
Sampling rate 64 samples/cycle
Cybersecurity Enable/disable communication ports
Communication Service Remote monitoring
User Language Spanish; French; English; Russian; Portuguese; German; Chinese
Product certifications CE conforming to IEC 61010-1; CULus conforming to UL 61010-1; CULus conforming to CSA C22.2 No 61010-1; RCM; EAC; C-tick
Mounting Mode Clip-on

Features and specifications of the METSEPM2220

Supply voltage: 44 to 277 V AC 45 to 65 Hz ± 10 %; 44 to 277 V DC ± 10 %. Network frequency: 50 Hz; 60 Hz. Communication protocols: Modbus RTU 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires; 2500 V. Display: Backlit LCD. Resolution: 128 x 128 pixels.

The meter has a monochrome backlit LCD of 128 x 128 pixels, four control buttons, and displays demand current and power with demand intervals configurable from 1 to 60 minutes. Real-time clock, time stamping and min/max for eight parameters are included.

Supply is 44 to 277 V AC or DC, the voltage range is 35 to 480 V AC between phases, and the current input handles 5 mA to 6 A. Settings are protected by an access code and a red LED gives energy pulses.

Choosing between PM2220 and PM2230

Both meters share the same housing, display and communications. The PM2230 raises the energy accuracy to class 0.5S and harmonics to the 31st, which matters for utility-type billing or power quality studies.

For plain monitoring of motors, air handling units and distribution feeders, the PM2220 is often enough, and it saves cost on multi-meter boards.

Selection checklist for the METSEPM2220

  • Accuracy: class 1 for energy.
  • Harmonics: THD to the 15th.
  • Supply: 44 to 277 V AC/DC.
  • Communication: RS485 Modbus RTU.
  • Panel cut-out: 96 x 96 mm.
  • CT secondary: 1 A or 5 A.

Installation of the METSEPM2220

Mount the meter in the panel with the supplied clip. Wire voltage and CT inputs per the diagram and short the CT before wiring changes. Enter the CT ratio, the wiring mode and the nominal frequency.

Check readings against a clamp meter and set demand interval to match the utility tariff. Save settings by writing down the setup for each meter.

Typical applications of the METSEPM2220 in Oman and the GCC

In Oman and the GCC, EasyLogic meters are common on motor control centres, chiller plants and commercial feeders. The IP54 front is adequate for indoor switchrooms.

Dimensions, environment and approvals of the METSEPM2220

For the METSEPM2220, plan the mounting space from the datasheet: 96 mm (W) x 96 mm (H) x Total : 76.09 mm; Embedded : 61.64 mm (D). The METSEPM2220 weighs 300 g. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.

Ambient temperature limits in the datasheet: -10 to 60 °C. Relative humidity: 5 to 95 % 50 °C. Ingress protection: IP54 front: conforming to IEC 60529; IP30 body: conforming to IEC 60529. Operating altitude: <= 2000 m. Certifications listed for this reference: CE conforming to IEC 61010-1; CULus conforming to UL 61010-1; CULus conforming to CSA C22.2 No 61010-1; RCM; EAC; C-tick.

Information to send with an RFQ for the METSEPM2220

  • Full reference and quantity required
  • Existing equipment, panel or rack it must fit
  • Supply voltage, load or signal details of the application
  • Required delivery location and timing
  • Whether a spare, a replacement or a new installation

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.

Other Models in the Se Pm2200 Range

Seven Star LLC supplies models from the Se Pm2200 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric METSEPM2220 EasyLogic PM2220 Power andPower Meters & Power QualityYou are viewing this model
Schneider Electric METSEPM2230 EasyLogic PM2230 Power andPower Meters & Power QualityView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric METSEPM2220 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric METSEPM2220 EasyLogic PM2220

Answers from our engineering team on installation, compatibility and integration.

01What accuracy class does the METSEPM2220 have?
The datasheet gives Class 1 active energy IEC 62053-21; Class 1 reactive energy IEC 62053-24; Class 5 harmonic distortion (I THD & U THD).
02What supply does the METSEPM2220 use?
The datasheet gives 44 to 277 V AC 45 to 65 Hz ± 10 %; 44 to 277 V DC ± 10 %.
03What display does the METSEPM2220 have?
The datasheet gives 128 x 128 pixels.
04What communication does the METSEPM2220 support?
The datasheet gives Modbus RTU 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires; 2500 V.
05What is the net weight of the METSEPM2220?
The datasheet gives 300 g.