Schneider Electric METSEPM3250 PowerLogic PM3250 DIN Rail Power

Description

METSEPM3250 a PM3250 DIN-rail multi-tariff power meter

The METSEPM3250 is a Schneider Electric product listed in the datasheet as: PM3250 power meter – RS485. The METSEPM3250 is a compact PowerLogic PM3000 series meter in a DIN-rail clip-on format with a backlit LCD and RS485 Modbus. It is intended for sub-metering and cost allocation in buildings and small plants, with multi-tariff energy registers and harmonics up to the 15th. Seven Star LLC supplies the METSEPM3250 in Oman and the GCC as an independent supplier based in Muscat.

Decoding the reference: PM3250 is the DIN rail model of the PM3000 range with RS485 communication, as in the title. The PM3255 is the related variant with additional outputs.

Technical specifications of the METSEPM3250

Parameter Specification
Manufacturer / part number Schneider Electric / METSEPM3250
Description PM3250 power meter – RS485
Range PowerLogic
Product name PowerLogic PM3000
Product or Component Type Power meter
Device short name PM3250
Market segment Buildings small building cost management: billing: sub feeder; Buildings medium building cost management: billing: sub feeder
Power quality analysis up to the 15th harmonic
Device Application Multi-tariff; Power monitoring; Sub billing
Type of measurement Active and reactive power; Apparent power; Current; Voltage; Energy; Power factor; Frequency; Total current harmonic distortion THD (I)
supply voltage 100 to 277 V AC 45 to 65 Hz; 173 to 480 V AC 45 to 65 Hz; 100 to 300 V DC
Network Frequency 60 Hz; 50 Hz
Line Rated Current 5A; 1A
type of network 1P + N; 3P; 3P + N
Power Consumption in VA 5 VA
Display Type Backlit LCD
Display Resolution 128 x 96 pixels
Sampling rate 32 samples/cycle
Measurement current 0.02 to 1.2 A; 0.05 to 6 A
Analogue input type Current 0 to 5 A; Current 0 to 1 A
Measurement voltage 50 to 330 V AC 45 to 65 Hz direct; 50 to 330 V AC 45 to 65 Hz phase to neutral; 80 to 570 V AC 45 to 65 Hz direct; 80 to 570 V AC 45 to 65 Hz phase to phase
Frequency measurement range 45 to 65 Hz
Number of inputs 0
Measurement accuracy Current 0.3 % 0.5 to 6 A; Current 0.5 % 0.1 to 1.2 A; Voltage 0.3 % 50 to 330 V; Voltage 0.3 % 80 to 570 V
Accuracy class Class 0.5S active energy IEC 62053-22; Class 1 active energy IEC 62053-21; Class 2 reactive energy IEC 62053-23
Number of Outputs 0
Information displayed Tariff 4
Communication port protocol Modbus 9.6 to 38.4 kbauds
Communication port support RS485
Data recording Time stamping; Min/max of instantaneous values; 5 alarms
Mounting Mode Clip-on
Mounting support DIN rail
Standards BS EN 61557-12; IEC 61557-12; EN 61557-12; BS EN 61326-1; IEC 61326-1; EN 61326-1; BS EN 62052-11; IEC 62052-11; EN 62052-11; BS EN 62053-21
Product certifications CE IEC 61010-1 safety; CE EN 61557-12 power monitor; CE EN/IEC 61326-1 EMC; UKCA BS EN 61010-1 safety; UKCA BS EN 61557-12 power monitor
Width 90 mm
Depth 70 mm
Height 95 mm
Net Weight 0.26 kg
Electromagnetic compatibility Electrostatic discharge level 4 conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3
Overvoltage category III
IP degree of protection IP40 front panel: conforming to IEC 60529; IP20 body: conforming to IEC 60529
Relative humidity 5 to 95 % 50 °C

Measurements and inputs of the METSEPM3250

Network frequency: 60 Hz; 50 Hz. Analogue input types: Current 0 to 5 A; Current 0 to 1 A. Communication protocols: Modbus 9.6 to 38.4 kbauds. Display: Backlit LCD. Resolution: 128 x 96 pixels.

The meter supports 1P+N, 3P and 3P+N networks with direct measurement of 50 to 330 V AC and CT inputs for 1 A and 5 A secondaries. Accuracy classes include 0.5S for active energy per IEC 62053-22 and class 1 per IEC 62053-21, with current and voltage accuracy of 0.3 percent in the stated ranges.

The display is a backlit LCD of 128 x 96 pixels, and the sampling rate is 32 samples per cycle. A wide supply range covers 100 to 277 V AC, 173 to 480 V AC and 100 to 300 V DC, so one reference suits many installations.

Where the METSEPM3250 is used

It records time-stamped events, min/max values and five alarms, and supports four tariffs. This makes it suitable for tenant billing, department energy allocation and monitoring of individual feeders.

It has no digital inputs or outputs in the datasheet, so pulse outputs are not available on this variant. The sibling METSEPM3255 provides additional I/O for those uses.

Selection checklist for the METSEPM3250

  • Network: single phase or three phase, 3 or 4 wire.
  • Measurement: direct to 330 V or via CT and VT.
  • Accuracy class: 0.5S for revenue-type use.
  • Communication: RS485 Modbus.
  • Tariffs: up to four.
  • Mounting: DIN rail, 90 mm width.

Installation and configuration of the METSEPM3250

Clip the meter onto the rail and wire voltage and current. Set the CT ratio and wiring mode in the menu, and check the phase sequence and sign of power with a known load.

Set the Modbus address and speed, and verify communication from the energy management system. Record the meter serial number and location in the metering schedule.

Typical applications of the METSEPM3250 in Oman and the GCC

In Oman and the GCC, sub-metering is used in commercial buildings, hotels, labour camps and plants for cost allocation and energy audits. Because supplies vary, the wide supply range is helpful.

Dimensions, environment and approvals of the METSEPM3250

For the METSEPM3250, plan the mounting space from the datasheet: 90 mm (W) x 95 mm (H) x 70 mm (D). The METSEPM3250 weighs 0.26 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.

Ambient temperature limits in the datasheet: -25 to 70 °C. Relative humidity: 5 to 95 % 50 °C. Ingress protection: IP40 front panel: conforming to IEC 60529; IP20 body: conforming to IEC 60529. Operating altitude: < 3000 m. Standards listed: BS EN 61557-12; IEC 61557-12; EN 61557-12; BS EN 61326-1; IEC 61326-1; EN 61326-1; BS EN 62052-11; IEC 62052-11; EN 62052-11; BS EN 62053-21. Certifications listed for this reference: CE IEC 61010-1 safety; CE EN 61557-12 power monitor; CE EN/IEC 61326-1 EMC; UKCA BS EN 61010-1 safety; UKCA BS EN 61557-12 power monitor.

Information to send with an RFQ for the METSEPM3250

  • Full reference and quantity required
  • Existing equipment, panel or rack it must fit
  • Supply voltage, load or signal details of the application
  • Required delivery location and timing
  • Whether a spare, a replacement or a new installation

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.

Other Models in the Se Pm3000 Range

Seven Star LLC supplies models from the Se Pm3000 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric METSEPM3250 PowerLogic PM3250 DIN Rail PowerPower Meters & Power QualityYou are viewing this model
Schneider Electric METSEPM3255 PowerLogic PM3255 DIN Rail PowerPower Meters & Power QualityView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric METSEPM3250 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric METSEPM3250 PowerLogic PM3250

Answers from our engineering team on installation, compatibility and integration.

01What supply does the METSEPM3250 accept?
The datasheet gives 100 to 277 V AC 45 to 65 Hz; 173 to 480 V AC 45 to 65 Hz; 100 to 300 V DC.
02What display does the METSEPM3250 have?
The datasheet gives Backlit LCD.
03What accuracy class does the METSEPM3250 list?
The datasheet gives Class 0.5S active energy IEC 62053-22; Class 1 active energy IEC 62053-21; Class 2 reactive energy IEC 62053-23; Class C active energy EN 50470-3.
04What communication does the METSEPM3250 support?
The datasheet gives Modbus 9.6 to 38.4 kbauds.
05What is the net weight of the METSEPM3250?
The datasheet gives 0.26 kg.