Brand:

Pfannenberg PF 32000 230V IP54 Filterfan, 98-108 m3/h

Description

PF 32000 230V IP54 filterfan: decoded article 11632101055

The PF 32000 230V IP54 is a installation size 3 filterfan with 230 V AC supply from Pfannenberg, intended to move cabinet-external air through a filter mat and into an electrical enclosure. It is built into a door or side panel cut-out and removes heat by exchanging the warm enclosure air for cooler ambient air, so it only works when the surrounding air is cooler than the maximum acceptable temperature inside the cabinet.

The model name decodes as follows: PF is the filterfan family, 32000 identifies installation size 3 (the cut-out and airflow class), 230 V AC is the supply voltage and IP54 is the protection class of the filterfan face. The full order number for this exact variant is 11632101055. This size-3 unit is the mid-small workhorse of the family, with 98 to 108 m³/h of free airflow and only 19 W of electrical draw.

Technical specifications of the PF 32000 230V IP54

Parameter Specification
Manufacturer / part number Pfannenberg / PF 32000 230V IP54 (article 11632101055)
Supply voltage AC 230 V ±10 %, 50 / 60 Hz
Unimpeded airflow 98 m³/h at 50 Hz, 108 m³/h at 60 Hz
Airflow with exhaust filter 73 m³/h at 50 Hz, 80 m³/h at 60 Hz
Power consumption 19 W at 50 Hz, 18 W at 60 Hz
Connection Terminal strip
Pre-fuse gG, 6 A
Protection IP54; NEMA Type 12
Filter Standard filter mat, 88 % filtration efficiency
Bearing Sleeve bearing
Ambient temperature -40 °C to +55 °C
Housing Injection-moulded thermoplastic, self-extinguishing, UL 94 V0
Colour RAL 7035
Cut-out (H x W) 177 mm x 177 mm
Dimensions (H x W x D) 202 mm x 202 mm x 93 mm; installation depth 87 mm
Weight 0.87 kg
UL file number E489500

Data are from the product page for article 11632101055. The page lists approvals cURus, EAC and CAS for the filterfan series.

How the PF 32000 230V filterfan works

It sits between the PF 22000 and the PF 42500 in the series. At 202 mm square on the face it fits typical control cabinets and motor starter panels, and with a standard filter mat it is the economical IP54 option when the site air is moderately clean.

In the PF 32000 230V IP54, air enters through the louvred front cover, passes through the filter mat and is pushed into the enclosure by a single axial fan. Warm air leaves the cabinet through a second opening, usually fitted with a matching exhaust filter, so that dust cannot enter through the outlet either. The louvres are shaped to give a high airflow for the size of the housing and to keep splash water and falling debris away from the filter mat.

Because the PF 32000 230V IP54 only moves air, the achievable cooling depends on the temperature difference between the inside and the outside of the enclosure and on the pressure drop of the filters and any rainhood. A thermostat is normally used to switch the fan on at a set cabinet temperature, which saves power and extends filter life.

Fit in the system and related Pfannenberg parts

Wiring is via a terminal strip, not the flying lead found on the size-1 unit, which makes field connection easier on thick cabinet doors or when the fan is replaced.

The same family covers installation sizes 1 to 6, with sibling models such as PF 11000, PF 22000, PF 32000, PF 42500, PF 43000, PF 65000 and the slim PF 67000 SL. The exhaust counterpart carries the PFA prefix and shares the cut-out, so a filterfan and an exhaust filter of the same size can be combined for forced circulation.

  • Exhaust filter, grey: article 11730001055
  • Spare filter mats, pack of 5: article 18611600031
  • Thermostat: article 17121000000
  • Hygrostat: article 17207000000
  • Rainhood in stainless steel: article 18102000017

Selection and ordering checklist for the PF 32000 230V IP54

Before ordering the PF 32000 230V IP54, confirm that the following points are settled so the correct variant is quoted:

  • Cabinet heat load in watts and the permitted internal temperature
  • Highest outdoor or room air temperature; a filterfan only cools when ambient is below the enclosure limit
  • Supply: 230 V AC; other voltages carry other article numbers
  • Cut-out of 177 mm x 177 mm and the installation depth behind the panel
  • Choice between IP54 (standard filter) and IP55 (fluted filter, UV-resistant) for the same size

If the heat load in the panel is above roughly 100 W and the cabinet stays within a few degrees of ambient, a size-3 unit with an exhaust filter is a typical starting point; larger loads may justify size 4 or a cooling unit.

Installation, commissioning and maintenance of the PF 32000 230V IP54

Installing the PF 32000 230V IP54 uses a cut-out in the cabinet wall and the tool-free four-corner fastening of the Pfannenberg filterfan. A poured foam seal on the frame is pressed against the panel, which keeps the stated protection class intact without a separate gasket. Mount the fan so that the airflow is from outside to inside and place the exhaust outlet as far from the inlet as practical, ideally at the opposite side and higher up, so warm air rises out of the enclosure.

Connect the PF 32000 230V IP54 supply with the fuse stated in the data table and protect the circuit as described in the manual. For commissioning, run the fan for several minutes and confirm direction of air movement at the louvres, then check the enclosure temperature under real load.

  • Inspect the filter mat at each service visit and replace it when visibly loaded; spare mats come in packs of five
  • Verify that the exhaust opening is clear and that cables do not obstruct the louvres
  • Terminal strip wiring should be re-checked for tightness after the first thermal cycles on site

This 230 V AC variant suits panels where a mains supply is already present for lighting or sockets. For 24 V DC control cabinets without mains, request the DC article 11632801055 instead, so that the fan is not powered from an additional transformer.

Typical applications in Oman and the GCC

Standard applications include motor control centres, PLC panels, drive cabinets and package-unit control boxes where the ambient air is clean and cooler than the enclosure limit.

Across the region, filterfans are used on control panels in oil and gas facilities, power stations and substations, desalination plants and petrochemical sites, where cabinets sit in electrical rooms or outdoor kiosks. Ambient temperatures above +40 °C for much of the year, fine sand and high humidity near the coast mean that the filter mat class, the protection class and the thermal margin should be checked rather than assumed. Where outdoor ambient air can approach the allowed enclosure temperature, a cooling unit or heat exchanger is the better choice than a filterfan.

Variants and voltages in the family of the PF 32000 230V IP54

The table lists the article numbers shown by the manufacturer for the same size, so you can see which variants exist around the one requested.

Order number Supply Protection
11632101055 230 V AC IP54 – this variant
11632151055 115 V AC IP54
11632851055 12 V DC IP54
11632801055 24 V DC IP54
11632701055 48 V DC IP54
11632103055 230 V AC IP55 fluted filter

Information to send with an RFQ for the PF 32000 230V IP54

A complete request avoids delays. Please provide:

  • Part number or article number, for example PF 32000 230V IP54 / 11632101055
  • Quantity and whether exhaust filters, spare filter mats, thermostat or rainhood are needed
  • Supply voltage and frequency available at the cabinet
  • Maximum ambient temperature and the heat load to be removed, if you want a sizing opinion
  • Site conditions: indoor room, outdoor kiosk, sand, oil mist or salt air
  • Delivery destination in Oman or the GCC and required date

Documents and quotation

A product sheet for the PF 32000 230V IP54 series is attached on this page, and it shows the airflow data, article numbers for every voltage, accessory article numbers and the performance curves for the size.

To receive a quotation for the PF 32000 230V IP54, send us the part number, the quantity and the delivery destination in Oman or the GCC. Seven Star LLC is an independent supplier based in Muscat and confirms lead time and availability against each request.

Other Models in the Pf Filterfan Ip54 Range

Seven Star LLC supplies models from the Pf Filterfan Ip54 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pfannenberg PF 11000 230V IP54 Filterfan, 19-24 m3/hEnclosure Climate ControlView details
Pfannenberg PF 32000 230V IP54 Filterfan, 98-108 m3/hEnclosure Climate ControlYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pfannenberg PF 32000 230V IP54 Product Sheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pfannenberg is the German maker of thermal management and signalling products for electrical enclosures and industry: filter fans, cooling units, air-to-water heat exchangers, chillers, heaters, sirens and beacons. Otto Pfannenberg, an electrical engineer, founded the company in Hamburg in 1954, and in 1958 he invented the filter fan to stop components in control cabinets from overheating. Pfannenberg is still family-owned and headquartered in Hamburg.

Seven Star LLC is an independent supplier in Muscat. We list Pfannenberg signalling devices and enclosure climate products for panel builders and plant engineers in Oman and the GCC.

Pfannenberg company profile

Founded 1954, Hamburg, Germany
Founder Otto Pfannenberg, electrical engineer
Headquarters Hamburg, Germany; North American headquarters in Lancaster, New York
Ownership Family-owned
Product families PF Filterfans, DTS and DTI cooling units, air-to-water heat exchangers, process chillers, enclosure heaters and thermostats, PA and DS sirens, beacons and combined signalling devices

Milestones

  • 1954: Otto Pfannenberg founds the company in Hamburg.
  • 1958: Pfannenberg invents the filter fan for control cabinets.
  • 1962: The company introduces an industrial flashing light that does not need a bulb change after activation.

Pfannenberg product series

Signalling devices include the PATROL PA X combined flashing sounders from 105 to 122 dB(A), the PYRA flashing light sounder, the PRO 10-Ex sounder for zone 2 and zone 22, and the INTENSE BR 50 modular LED signal tower.

Thermal management covers FLZ enclosure thermostats, twin thermostats, hygrostats and Peltier thermostats, FLH radiant heaters and PFH and FLH-T fan heaters, PF filter fans in several installation sizes up to 785 m3/h and the PTF roof-mounted filter fan, and DTS and DTI cooling units, including the DTI outdoor version.

Where Pfannenberg products are used

Control and drive cabinets on machines and in plant rooms, outdoor enclosures in hot and humid climates, and alarm and evacuation signalling in industrial buildings and process areas. In the Gulf, cabinet cooling and condensation control are the main reasons for specifying Pfannenberg thermal products.

Pfannenberg products we list

Family Examples
Enclosure Climate Control FLH 060 Radiant Enclosure Heater, FLH-T 600 Fan Heater with Integrated, FLZ 510 Enclosure Thermostat, FLZ 541 Twin Thermostat, FLZ 600 Hygrostat for Control Cabinets, FLZ 700 Peltier Unit Thermostat, PFH 650 Compact Fan Heater
Fire & Gas Detectors INTENSE BR 50 Modular LED Signal Tower, PA X 1-05 PATROL Flashing Sounder 105 dB(A), PA X 20-10 PATROL Flashing Sounder 122 dB(A), PA X 5-05 PATROL Flashing Sounder 107 dB(A), PRO 10-Ex Explosion-Proof Sounder 116 dB(A), PY X-MA-05 PYRA Flashing Light Sounder 101
Cooling DTI 8401P Outdoor Cooling Unit, DTS 3061 Cooling Unit, PF 22.000 DC Filterfan, PF 66.000 Filterfan, PTF 60.500 Roof-Mounted Filterfan

Ordering Pfannenberg products: what we need

Send the article number or full designation, such as PA X 1-05 or DTI 8401P. For signalling devices add the supply voltage, lens and housing colour and any required approval such as EN 54-3 or an Ex certificate. For cooling units give the cooling capacity, voltage and frequency, mounting (side or roof, internal or external) and the ambient temperature. For fans and heaters give the installation size, voltage and airflow or heating power.

Facts checked against Pfannenberg's published company history, October 2026.

FAQ

Questions about the Pfannenberg PF 32000 230V IP54 Filterfan, 98-108

Answers from our engineering team on installation, compatibility and integration.

01How much air does the PF 32000 230V IP54 move?
Free airflow is 98 m³/h at 50 Hz and 108 m³/h at 60 Hz. Fitting a PFA 30000 exhaust filter reduces this to 73 and 80 m³/h.
02What cut-out does it need?
A 177 mm x 177 mm cut-out is required. The unit measures 202 mm x 202 mm on the face and needs an installation depth of 87 mm.
03What is the difference between the IP54 and IP55 versions of this size?
The IP54 version uses a standard filter mat with 88 % efficiency; the IP55 version uses a fluted filter at 91 % and a UV-resistant cover. The IP55 article for 230 V is 11632103055.
04How is it wired?
The electrical connection is a terminal strip, and a gG 6 A pre-fuse is specified. Follow the manual for wiring and earthing.
05Does it have a motor with sleeve or ball bearings?
The page lists a sleeve bearing for this variant. Ball-bearing versions apply to other voltages and sizes, so check the article number.