Brand:

Pfannenberg Quadro LED-HI 3G/3D Ex LED Multi-Function Light

Description

Quadro LED-HI 3G/3D Ex LED multi-function light

The Quadro LED-HI 3G/3D is an LED signalling light from Pfannenberg for Zone 2 gas and Zone 22 dust areas. Unlike a xenon flasher it offers three selectable operating modes in one housing: continuous light, blinking light and flashing light, with brightness adjustable between 15 % and 100 % of a 75 cd maximum. Seven Star LLC supplies the Quadro LED-HI 3G/3D in Oman and the GCC as an independent supplier in Muscat.

What the Quadro LED-HI 3G/3D offers

Four high-output LEDs sit under a clear or coloured polycarbonate lens in the square Quadro housing, 130 x 130 x 130 mm, which is also used for the xenon Quadro F12. The sheet lists flashing frequencies of 0.1, 0.5, 0.75, 1 and 2 Hz, and blinking at 1 or 2 Hz, so one device can serve as a steady status lamp, a slow blink or a fast alarm flash. The operating mode is set internally on the 115/230 V version, and may also be controlled externally on the 12–48 V DC version.

Technical specifications of the Quadro LED-HI 3G/3D

Parameter Specification
Manufacturer / part number Pfannenberg / Quadro LED-HI 3G/3D
Light source 4 high-output LEDs; service life over 50,000 hours
Light intensity 75 cd (clear lens), adjustable 15–100 %; max. viewing distance 201 m
Operating modes Continuous; blinking 1 or 2 Hz; flashing 0.1, 0.5, 0.75, 1 or 2 Hz
Supply, version 1 115/230 V AC/DC, range 90–253 V; 65 mA at 230 V AC (red, continuous)
Supply, version 2 12–48 V DC, range 11–60 V; 195 mA at 24 V DC
Explosion protection II 3G Ex nR IIC T6 Gc; II 3D Ex tc IIIB T80 °C Dc IP66/67; -20 °C ≤ Ta ≤ +55 °C
Testing body Pfannenberg PDG 19.0007 X
Operating / storage temperature -20 °C to +55 °C / -40 °C to +70 °C; humidity 90 %
Protection IP 66 / IP 67, IK08, protection class II, duty cycle 100 %
Materials Lens polycarbonate; housing polycarbonate, light grey RAL 7035
Connection Cage clamp 0.08–2.5 mm²; 2 x M20 x 1.5 (one sealing screw, one cable connection)
Weight 500 g

How the Quadro LED-HI 3G/3D saves effort over a fixed-function beacon

Because intensity and mode are adjustable, one stock item can replace several fixed-function lamps: the same part can serve as a running indicator, a pre-alarm blinker and a full alarm flasher at different sites. Reduced brightness is useful in dark control rooms or when beacons face operators at close range, while 100 % is intended for outdoor alarm duty. The device carries double-pole terminals and a wide-range supply so a single type covers 115 V and 230 V networks, AC or DC.

Where the Quadro LED-HI 3G/3D fits and related devices

The Quadro LED-RGB 3G/3D from the same family provides coloured light at 8 cd, and the Quadro F12-3G/3D ATEX gives a xenon flash of 7.5 J and 84 cd. For Zone 1 service the BExBG and CWB-ATEX flashing lights are listed instead. The LED-HI is the practical choice when a Zone 2 site wants long LED life, multiple modes and low current draw rather than the highest flash energy.

Selection and ordering checklist for the Quadro LED-HI 3G/3D

  • Confirm Zone 2 and Zone 22 installation and the IIC and IIIB groups.
  • Select the supply version: 115–230 V AC/DC or 12–48 V DC.
  • Select lens colour; the 75 cd figure is for a clear lens.
  • Decide on operating mode and whether external mode control is needed (DC version).
  • Check ambient temperature stays within -20 to +55 °C.

Installation and maintenance of the Quadro LED-HI 3G/3D

The housing is fixed with M4 screws on a 113.5 mm pitch through holes of 4.5 mm diameter, or with the external lugs supplied, and may be mounted in any position. Use an M20 x 1.5 gland suitable for the area and close the other entry with the sealing screw. Set the mode and intensity as the operating instructions describe before closing the cover. The housing is impact-rated IK08; routine care consists of cleaning the lens and checking gaskets and cable entries.

Typical applications of the Quadro LED-HI 3G/3D in Oman and the GCC

Typical Gulf uses include status and alarm indication on Zone 2 pump skids, metering stations, chemical dosing areas, pipe racks, bulk powder handling with Zone 22 and utility blocks at power and desalination plants. Where summer temperatures approach the +55 °C limit, shade the unit or compare it with the site temperature data.

Planning alarm and status schemes with the Quadro LED-HI 3G/3D

A common design is to assign modes by meaning: continuous light for a running or healthy state, slow blinking for a warning and fast flashing for a trip or alarm. Since the LED-HI can be set to different frequencies, the same type can be used across all three duties and the mode list recorded in the loop documents. Lower brightness settings reduce glare where the light faces a walkway, and full output is better for outdoor positions in strong sun. External mode control on the DC version allows a PLC or relay to change the pattern without replacing the light.

Keep the operating instructions and the certificate reference with the project documents. Record which mode and intensity was set at commissioning and check it again after any maintenance that opens the cover, so the alarm philosophy remains consistent from unit to unit.

Information to send with an RFQ for the Quadro LED-HI 3G/3D

  • Quadro LED-HI 3G/3D, supply version and lens colour
  • Zone, gas and dust group, ambient temperature
  • Required operating mode and control method
  • Quantity, delivery site and certificate requirements

Documents and quotation

The Pfannenberg product sheet for the Quadro LED-HI 3G/3D is attached on this page and contains the electrical data and dimensions.

Send the supply version, lens colour and quantity and Seven Star LLC will confirm availability and a quotation.

Other Models in the Pf Quadro Ex Range

Seven Star LLC supplies models from the Pf Quadro Ex range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pfannenberg Quadro F12-3G/3D ATEX Flashing Light 7.5 JAlarm Beacons & Call PointsView details
Pfannenberg Quadro LED-HI 3G/3D Ex LED Multi-Function LightAlarm Beacons & Call PointsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Quadro LED-HI 3G/3D Product Sheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pfannenberg is the German maker of thermal management and signalling products for electrical enclosures and industry: filter fans, cooling units, air-to-water heat exchangers, chillers, heaters, sirens and beacons. Otto Pfannenberg, an electrical engineer, founded the company in Hamburg in 1954, and in 1958 he invented the filter fan to stop components in control cabinets from overheating. Pfannenberg is still family-owned and headquartered in Hamburg.

Seven Star LLC is an independent supplier in Muscat. We list Pfannenberg signalling devices and enclosure climate products for panel builders and plant engineers in Oman and the GCC.

Pfannenberg company profile

Founded 1954, Hamburg, Germany
Founder Otto Pfannenberg, electrical engineer
Headquarters Hamburg, Germany; North American headquarters in Lancaster, New York
Ownership Family-owned
Product families PF Filterfans, DTS and DTI cooling units, air-to-water heat exchangers, process chillers, enclosure heaters and thermostats, PA and DS sirens, beacons and combined signalling devices

Milestones

  • 1954: Otto Pfannenberg founds the company in Hamburg.
  • 1958: Pfannenberg invents the filter fan for control cabinets.
  • 1962: The company introduces an industrial flashing light that does not need a bulb change after activation.

Pfannenberg product series

Signalling devices include the PATROL PA X combined flashing sounders from 105 to 122 dB(A), the PYRA flashing light sounder, the PRO 10-Ex sounder for zone 2 and zone 22, and the INTENSE BR 50 modular LED signal tower.

Thermal management covers FLZ enclosure thermostats, twin thermostats, hygrostats and Peltier thermostats, FLH radiant heaters and PFH and FLH-T fan heaters, PF filter fans in several installation sizes up to 785 m3/h and the PTF roof-mounted filter fan, and DTS and DTI cooling units, including the DTI outdoor version.

Where Pfannenberg products are used

Control and drive cabinets on machines and in plant rooms, outdoor enclosures in hot and humid climates, and alarm and evacuation signalling in industrial buildings and process areas. In the Gulf, cabinet cooling and condensation control are the main reasons for specifying Pfannenberg thermal products.

Pfannenberg products we list

Family Examples
Enclosure Climate Control FLH 060 Radiant Enclosure Heater, FLH-T 600 Fan Heater with Integrated, FLZ 510 Enclosure Thermostat, FLZ 541 Twin Thermostat, FLZ 600 Hygrostat for Control Cabinets, FLZ 700 Peltier Unit Thermostat, PFH 650 Compact Fan Heater
Fire & Gas Detectors INTENSE BR 50 Modular LED Signal Tower, PA X 1-05 PATROL Flashing Sounder 105 dB(A), PA X 20-10 PATROL Flashing Sounder 122 dB(A), PA X 5-05 PATROL Flashing Sounder 107 dB(A), PRO 10-Ex Explosion-Proof Sounder 116 dB(A), PY X-MA-05 PYRA Flashing Light Sounder 101
Cooling DTI 8401P Outdoor Cooling Unit, DTS 3061 Cooling Unit, PF 22.000 DC Filterfan, PF 66.000 Filterfan, PTF 60.500 Roof-Mounted Filterfan

Ordering Pfannenberg products: what we need

Send the article number or full designation, such as PA X 1-05 or DTI 8401P. For signalling devices add the supply voltage, lens and housing colour and any required approval such as EN 54-3 or an Ex certificate. For cooling units give the cooling capacity, voltage and frequency, mounting (side or roof, internal or external) and the ambient temperature. For fans and heaters give the installation size, voltage and airflow or heating power.

Facts checked against Pfannenberg's published company history, October 2026.

FAQ

Questions about the Pfannenberg Quadro LED-HI 3G/3D Ex LED

Answers from our engineering team on installation, compatibility and integration.

01Which modes does the Quadro LED-HI 3G/3D offer?
Continuous light, blinking at 1 or 2 Hz and flashing at 0.1, 0.5, 0.75, 1 or 2 Hz.
02Is brightness adjustable?
Yes. The 75 cd maximum, with a clear lens, can be adjusted from 15 % to 100 %.
03What zones is it suitable for?
Zone 2 for gas (II 3G Ex nR IIC T6 Gc) and Zone 22 for dust (II 3D Ex tc IIIB T80 °C Dc).
04What supplies are covered?
One version accepts 115/230 V AC or DC from 90 to 253 V, the other 12 to 48 V DC from 11 to 60 V.
05What is the expected LED life?
The sheet states a light source life of more than 50,000 hours.