Brand: Pfannenberg
Pfannenberg Quadro F12-3G/3D ATEX Flashing Light 7.5 J
Description
Quadro F12-3G/3D ATEX xenon flashing light for Zone 2 and Zone 22
The Quadro F12-3G/3D ATEX is a xenon flashing light from Pfannenberg designed as a visual alarm in areas where an explosive atmosphere is possible but not expected in normal operation. It is rated for gas Zone 2 and dust Zone 22, delivers 7.5 J of flash energy in a compact 130 x 130 x 130 mm polycarbonate housing, and can be used indoors and outdoors. Seven Star LLC supplies the Quadro F12-3G/3D ATEX in Oman and the GCC as an independent supplier in Muscat, and this page explains how the type is organised so that an RFQ can be written correctly the first time.
Reading the Quadro F12-3G/3D ATEX designation
The name combines a family, a size and an approval statement. “Quadro” is the square-housing signalling family, “F12” identifies the 7.5 J xenon flash module, and “3G/3D” states the ATEX equipment category: 3G for gas atmospheres (Zone 2) and 3D for dust atmospheres (Zone 22). The ordering table in the product sheet then splits the device by supply and lens colour, with 230 V AC and 24 V DC versions each offered in several lens colours. A 115 V AC version is also listed in the data table.
Technical specifications of the Quadro F12-3G/3D ATEX
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Pfannenberg / Quadro F12-3G/3D ATEX |
| Light source | Xenon flash, 7.5 J flash energy |
| Flash rate | 0.83 Hz = 50 flashes per minute |
| Light intensity (DIN 5037, clear lens) | 84 cd; maximum signal reception range 229 m |
| Rated voltage | 230 V AC and 115 V AC (50/60 Hz); 24 V DC |
| Operating range | 195–253 V (230 V), 95–127 V (115 V), 18–30 V (24 V DC) |
| Nominal current | 90 mA (230 V), 140 mA (115 V), 360 mA (24 V DC) |
| Hazardous area | Category 3G (Zone 2) and 3D (Zone 22) |
| Gas groups / classes | Temperature classes T1 to T4; non-conductive dust provided the surface temperature stays within +105 °C |
| Ambient temperature | -20 °C to +45 °C operating; -40 °C to +70 °C storage |
| Protection | IP 66, impact resistance IK08, protection class II, duty cycle 100 % |
| Materials | Lens polycarbonate; housing polycarbonate, RAL 7035 (RAL 3000 optional) |
| Connection | Cage clamp terminals 0.08–2.5 mm²; 2 x M20 entries (one blanking plug, one cable connection) |
| Weight / size | 600 g; 130 x 130 x 130 mm |
How the Quadro F12-3G/3D ATEX produces its signal
A xenon flash tube is discharged through a lens that spreads the light sideways, which gives a very bright pulse with strong attention value compared with a steady lamp. The product sheet gives the light-source life as 70 % of initial light emission after 8,000,000 flashes, and the inrush current is limited (below 7 A for 150 µs on AC versions and below 5 A for 2 ms on 24 V DC), which matters when many beacons are switched from one relay or a PLC output module. A terminal arrangement lets additional flashing lights be supplied from the same connection point.
Where the Quadro F12-3G/3D ATEX fits and related devices
The Quadro F12-3G/3D ATEX is the xenon option in the Zone 2 and 22 part of the Pfannenberg Ex signalling range. The same Quadro housing is also made as the Quadro LED-HI 3G/3D, an LED multi-function light with 75 cd and selectable operating modes, and as the Quadro LED-RGB 3G/3D. For Zone 1 and Zone 21 duty the manufacturer lists different devices, such as the CWB-ATEX and the BExBG 05/10/15 flashing lights. Choose the F12 when a classic high-energy xenon flash is wanted and the area is classified Zone 2 or 22.
Selection and ordering checklist for the Quadro F12-3G/3D ATEX
- Confirm the hazardous area classification: Zone 2 and Zone 22 only for this category 3G/3D device.
- Check the required gas temperature class and, for dust, that the ambient and dust-layer conditions stay within the +105 °C surface temperature limit stated.
- Select the supply: 230 V AC, 115 V AC or 24 V DC, and check the available current on the alarm circuit.
- Select the lens colour and decide whether the red housing option (RAL 3000) is wanted.
- Assess mechanical exposure: the sheet notes the light is suitable for a low degree of mechanical danger and must be mounted with enough impact protection.
- If the 24 V DC EN 54-23 or CNBOP marked versions are needed for fire alarm use, state this in the RFQ.
Installation and maintenance of the Quadro F12-3G/3D ATEX
The housing is fixed with four M4 x 20 screws through mounting holes of 4.5 mm diameter on a 113 mm pitch, and the unit can be mounted in any position. Use an Ex-suitable cable gland in the M20 x 1.5 entry and close the unused entry with the supplied blanking plug so that the IP 66 rating is preserved. Terminate to the cage clamp terminals, observing the 0.08 to 2.5 mm² range. Fit the device out of reach of knocks, since the manufacturer states that a protective cage is not mandatory but that impact protection must be considered. Test the flash function at commissioning, keep lenses free from dust and chemical film, and plan replacement against the stated light-source life.
Typical applications of the Quadro F12-3G/3D ATEX in Oman and the GCC
In Oman and the Gulf the Quadro F12-3G/3D ATEX suits visual alarm points on Zone 2 process units, gas metering and compressor areas, fuel storage and loading bays, pump stations, petrochemical utility blocks and dusty bulk handling where Zone 22 applies. The upper ambient limit of +45 °C should be compared with the real shade temperature and solar load at the installation point, because exposed outdoor positions in summer can exceed it. Where the site is hotter or the area is Zone 1, a different device from the Ex signalling range should be considered.
Quadro F12-3G/3D ATEX at a glance
| Aspect | Quadro F12-3G/3D ATEX | Quadro LED-HI 3G/3D |
|---|---|---|
| Light source | Xenon flash, 7.5 J | 4 high-output LEDs |
| Intensity | 84 cd (clear lens) | 75 cd, adjustable 15–100 % |
| Operating modes | Flashing at 0.83 Hz | Continuous, blinking or flashing |
| Supply | 230 V AC, 115 V AC, 24 V DC | 115/230 V AC/DC or 12–48 V DC |
| Area | Zone 2 / 22 | Zone 2 / 22 |
Information to send with an RFQ for the Quadro F12-3G/3D ATEX
- Quadro F12-3G/3D ATEX, supply voltage and lens colour
- Area classification, gas group, temperature class and dust type
- Maximum ambient temperature at the mounting position
- Cable gland type and entry thread
- Required marking (EN 54-23, CNBOP, DNV) if any
- Quantity, delivery site and certificate requirements
Documents and quotation
The Pfannenberg product sheet for the Quadro F12-3G/3D ATEX is attached on this page and contains the electrical data, dimensions and article numbers.
Send the supply voltage, lens colour and quantity and Seven Star LLC will confirm availability and a quotation.
Datasheets & Documents
- Datasheet Quadro F12-3G/3D ATEX Product Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pfannenberg is the German maker of thermal management and signalling products for electrical enclosures and industry: filter fans, cooling units, air-to-water heat exchangers, chillers, heaters, sirens and beacons. Otto Pfannenberg, an electrical engineer, founded the company in Hamburg in 1954, and in 1958 he invented the filter fan to stop components in control cabinets from overheating. Pfannenberg is still family-owned and headquartered in Hamburg.
Seven Star LLC is an independent supplier in Muscat. We list Pfannenberg signalling devices and enclosure climate products for panel builders and plant engineers in Oman and the GCC.
Pfannenberg company profile
| Founded | 1954, Hamburg, Germany |
|---|---|
| Founder | Otto Pfannenberg, electrical engineer |
| Headquarters | Hamburg, Germany; North American headquarters in Lancaster, New York |
| Ownership | Family-owned |
| Product families | PF Filterfans, DTS and DTI cooling units, air-to-water heat exchangers, process chillers, enclosure heaters and thermostats, PA and DS sirens, beacons and combined signalling devices |
Milestones
- 1954: Otto Pfannenberg founds the company in Hamburg.
- 1958: Pfannenberg invents the filter fan for control cabinets.
- 1962: The company introduces an industrial flashing light that does not need a bulb change after activation.
Pfannenberg product series
Signalling devices include the PATROL PA X combined flashing sounders from 105 to 122 dB(A), the PYRA flashing light sounder, the PRO 10-Ex sounder for zone 2 and zone 22, and the INTENSE BR 50 modular LED signal tower.
Thermal management covers FLZ enclosure thermostats, twin thermostats, hygrostats and Peltier thermostats, FLH radiant heaters and PFH and FLH-T fan heaters, PF filter fans in several installation sizes up to 785 m3/h and the PTF roof-mounted filter fan, and DTS and DTI cooling units, including the DTI outdoor version.
Where Pfannenberg products are used
Control and drive cabinets on machines and in plant rooms, outdoor enclosures in hot and humid climates, and alarm and evacuation signalling in industrial buildings and process areas. In the Gulf, cabinet cooling and condensation control are the main reasons for specifying Pfannenberg thermal products.
Pfannenberg products we list
Ordering Pfannenberg products: what we need
Send the article number or full designation, such as PA X 1-05 or DTI 8401P. For signalling devices add the supply voltage, lens and housing colour and any required approval such as EN 54-3 or an Ex certificate. For cooling units give the cooling capacity, voltage and frequency, mounting (side or roof, internal or external) and the ambient temperature. For fans and heaters give the installation size, voltage and airflow or heating power.
Facts checked against Pfannenberg's published company history, October 2026.
Browse Pfannenberg products by category: Enclosure Climate Control, Fire & Gas Detectors, Cooling.
FAQ
Questions about the Pfannenberg Quadro F12-3G/3D ATEX Flashing Light
Answers from our engineering team on installation, compatibility and integration.
01What areas is the Quadro F12-3G/3D ATEX approved for?
It is a category 3G/3D device for gas Zone 2 and dust Zone 22. It is not intended for Zone 1 or Zone 21, where a category 2G/2D device is required.
02What is the flash energy and rate?
The flash energy is 7.5 J and the flash rate is 0.83 Hz, which is 50 flashes per minute.
03Which supply voltages are available?
The data table lists 230 V AC, 115 V AC and 24 V DC. Operating ranges are 195 to 253 V, 95 to 127 V and 18 to 30 V respectively.
04What is the ambient temperature range?
Operation is specified from -20 °C to +45 °C, with storage from -40 °C to +70 °C. Check the +45 °C limit against outdoor summer conditions.
05Is a protective cage required?
The sheet states a cage is not mandatory, but the light must be mounted with sufficient protection against impacts because it is rated for a low degree of mechanical danger.