- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser Prowirl F 200 Vortex Flowmeter
Description
Overview of the Endress+Hauser Prowirl F 200
The Endress+Hauser Prowirl F 200 is a flanged vortex flowmeter from the Proline 200 family, designed for saturated, superheated and wet steam, gases and liquids, including cryogenic fluids. It is offered in nominal diameters from DN 15 to 300 (½ to 12 in) and combines a robust, drift-free capacitive sensor with a dual-compartment transmitter housing. According to Technical Information TI01333D, the measuring principle complies with the international vortex standard ISO 12764, the meter body keeps the same accuracy down to a Reynolds number of 10,000, and wet steam detection is available for DN 25 to 300.
Seven Star LLC supplies the Endress+Hauser Prowirl F 200 to power plants, refineries, petrochemical units and utility contractors across the Sultanate of Oman and the GCC, with engineering support in Muscat. The meter is a frequent choice for steam distribution and boiler house metering, where integrated temperature and pressure measurement turns one instrument into a complete energy measuring point.
Measuring Principle of the Endress+Hauser Prowirl F 200
The Endress+Hauser Prowirl F 200 works on the principle of the Karman vortex street. When fluid flows past a bluff body in the measuring tube, vortices form alternately on both sides with opposite directions of rotation, each generating a local low pressure. A DSC capacitance sensor records these pressure fluctuations and converts them into electrical pulses. Within the application limits, vortex shedding frequency is proportional to volume flow, and the factory-calibrated K-factor depends only on the meter geometry, so above Re 10,000 it is independent of flow velocity, viscosity, density and of whether the medium is steam, gas or liquid.
The sensor has been burst-tested and tested against vibration and against thermal shocks of 150 K/s, and the capacitance technology is in use at more than 450,000 measuring points. There are no moving parts and no maintenance requirement, and the K-factor is not subject to long-term or zero-point drift. Endress+Hauser describes this as lifelong calibration in non-abrasive and non-corrosive media such as most water and steam applications, provided edge wear on the bluff body stays below 1 mm.
Engineering Design of the Endress+Hauser Prowirl F 200
Measuring tubes are made of stainless cast steel CF3M/1.4408, with cast Alloy C22 equivalent available for DN 15 to 150, and flanges are triple-certified 1.4404/F316/F316L to EN, ASME and JIS standards from PN 10 to PN 100 and Class 150 to 600, compliant with NACE MR0175 and MR0103. Sensor versions cover volume measurement from –40 to +260 °C, a high-temperature version from –200 to +400 °C, a mass version with Pt1000 temperature measurement in the sensor paddle, and mass steam or mass gas/liquid versions with an integrated pressure cell and industrial siphon. Seals include graphite, FPM, Kalrez and Gylon.
The Proline 200 transmitter is available in compact or remote form with aluminium or stainless CF3M housing rated IP66/67, Type 4X. Outputs include passive 4–20 mA HART, a second 4–20 mA, pulse, frequency and switch output, PROFIBUS PA, FOUNDATION Fieldbus, and PROFINET or Modbus TCP over Ethernet-APL. A four-line illuminated display with touch control lets the Endress+Hauser Prowirl F 200 be configured without opening the housing, and Heartbeat Technology provides integrated verification.
Key Features of the Endress+Hauser Prowirl F 200
The following points from TI01333D summarise the strengths of the Endress+Hauser Prowirl F 200:
- Volume flow measurement error below 0.75 % o.r. for liquids and below 1.0 % o.r. for gases and steam, or 0.65 % and 0.9 % with the PremiumCal 5-point calibration.
- Integrated temperature and pressure measurement for density and energy compensation of steam and gases.
- Wet steam detection and steam quality output for DN 25 to 300.
- Inlet run correction that shortens the required straight inlet to 10 × DN after elbows or reductions, with an additional error of ±0.5 % o.r.
- Typical operable flow range up to 49:1, with medium temperatures from –200 to +400 °C depending on the sensor version.
- Calculation of corrected volume, mass, energy and heat flow difference for steam, water, air and industrial gases.
- Use in flow monitoring systems up to SIL 2 in single-channel and SIL 3 in redundant architecture to IEC 61508.
- Heartbeat Technology for verification in operation, plus worldwide hazardous area approvals.
Industrial Applications of the Endress+Hauser Prowirl F 200
The Endress+Hauser Prowirl F 200 is used for steam generation and distribution, boiler efficiency monitoring, energy billing between plant areas, fuel gas and compressed air metering, nitrogen and other industrial gases, and liquids such as condensate, demineralised water and thermal oil. In Oman these duties are found in power and desalination plants, refinery steam networks in Sohar, petrochemical and fertiliser complexes, food and beverage factories with steam utilities in Rusayl and Salalah, and district utility systems.
Seven Star LLC supplies the meter sized to the actual process data, together with seals and certificates required by the project. For related flow tasks, buyers can review the earlier Endress+Hauser Prowirl 72F, the Promass F300 Coriolis mass flowmeter for direct mass measurement of liquids, or the t-mass 65F thermal mass flowmeter for gases.
Technical Specifications of the Endress+Hauser Prowirl F 200
Key data of the Endress+Hauser Prowirl F 200 from Technical Information TI01333D are listed below.
| Parameter | Specification |
|---|---|
| Model | Proline Prowirl F 200 (7F2C), flanged |
| Measuring principle | Vortex (Karman vortex street), DSC capacitance sensor |
| Nominal diameter | DN 15 to 300 (½ to 12 in) |
| Media | Saturated, superheated and wet steam; gases; liquids |
| Volume flow error (Re ≥ 10,000) | Liquids < 0.75 % o.r.; gas/steam < 1.0 % o.r. |
| Operable flow range | Typically up to 49:1 |
| Medium temperature | –40 to +260 °C standard; –200 to +400 °C high-temperature |
| Pressure ratings | PN 10 to PN 100; Class 150/300/600; JIS 10K/20K |
| Materials | CF3M/1.4408 measuring tube; 1.4404/F316/F316L flanges; Alloy C22 option |
| Outputs | 4–20 mA HART, pulse/frequency/switch, PROFIBUS PA, FOUNDATION Fieldbus, Ethernet-APL |
| Functional safety | SIL 2 single-channel, SIL 3 redundant (IEC 61508) |
| Transmitter ambient temperature | –40 to +80 °C (non-hazardous area) |
| Degree of protection | IP66/67, Type 4X |
How to Order
To order the Endress+Hauser Prowirl F 200, send Seven Star LLC the medium, minimum, normal and maximum flow, operating pressure and temperature, line size and flange rating, required outputs and any hazardous area or SIL requirement, and our instrumentation division will size the meter and return a formal quotation with lead time. Technical Information TI01333D can be downloaded from this page. Seven Star LLC is a trusted supplier of Endress+Hauser flow instruments in Oman and the GCC, with engineering support in Muscat.
Datasheets & Documents
- Datasheet Endress+Hauser Proline Prowirl F 200 Technical Information (TI01333D) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser Prowirl F 200 Vortex Flowmeter
Answers from our engineering team on installation, compatibility and integration.
01What media can the Endress+Hauser Prowirl F 200 measure?
It measures saturated, superheated and wet steam, gases and liquids, including cryogenic fluids, in line sizes from DN 15 to 300. It is optimised for steam applications.
02How accurate is the Prowirl F 200?
Above a Reynolds number of 10,000 the volume flow error is below 0.75 % of reading for liquids and below 1.0 % for gases and steam, improving to 0.65 % and 0.9 % with the PremiumCal 5-point calibration option.
03Can the Prowirl F 200 measure steam mass and energy directly?
Yes. Sensor versions with integrated temperature measurement, or with integrated pressure and temperature measurement, allow density and energy compensation, and the device can output mass flow, energy flow and steam quality.
04Which outputs and approvals are available for the Prowirl F 200?
Options include 4-20 mA HART, pulse/frequency/switch output, PROFIBUS PA, FOUNDATION Fieldbus and PROFINET or Modbus TCP over Ethernet-APL, with hazardous area approvals and SIL 2/SIL 3 suitability.
05Does Seven Star LLC supply the Endress+Hauser Prowirl F 200 in Oman?
Yes. Seven Star LLC is a trusted supplier of Endress+Hauser flowmeters and supplies the Prowirl F 200 with sizing, quotations and engineering support in Muscat for Oman and the GCC.


















Reviews
There are no reviews yet.