Brand: Beamex
Beamex MC6-Ex Intrinsically Safe Field Calibrator
Description
Overview
Beamex MC6-Ex is an intrinsically safe, documenting multifunction calibrator and fieldbus communicator for use in potentially explosive atmospheres. It is certified under ATEX, IECEx and North American schemes with the marking Ex ia IIC T4 Ga, which approves it for the tightest hazardous location, Zone 0. In practice this means a technician can carry one instrument into an area where flammable gases may be present and calibrate pressure, temperature and electrical signals without hot-work permits or additional safety equipment such as portable gas detectors.
Seven Star LLC supplies the Beamex MC6-Ex on request to oil, gas, petrochemical and power operators in Oman and the GCC, with engineering support in Muscat. Sites that already use the Beamex MC6 advanced field calibrator and communicator in the safe area can add the MC6-Ex for hazardous-area rounds while keeping one familiar user interface, one set of calibration procedures and the same Beamex calibration software.
Calibration and Communication Principle
The Beamex MC6-Ex works as a combined measure and source instrument. Internal and external pressure modules measure applied pressure, two simultaneous RTD or thermocouple channels measure temperature, and electrical circuits measure or generate voltage, current, resistance, frequency and pulses. A technician connects the device under test, selects the function and the instrument compares the reading with the reference, calculating error and pass or fail status against the tolerance defined for the instrument being calibrated.
In communicator mode the MC6-Ex reads and writes parameters of HART, FOUNDATION Fieldbus and Profibus PA field devices. Built-in loop power with the correct impedance for each bus removes the need for external supplies or resistors, and all three protocols can be installed in the same unit. The documenting calibrator mode stores as-found and as-left results and transfers them to Beamex CMX or LOGiCAL software, so calibration records are created automatically instead of being copied by hand into a logbook. Wireless data transfer over Bluetooth is available but must only be used in the safe area, and USB devices are not allowed in hazardous areas.
Engineering Design of the Beamex MC6-Ex
The Beamex MC6-Ex measures 207 x 231 x 80 mm and weighs 2.5 to 2.9 kg. Its robust IP65-rated, dust-tight and water-resistant casing has integrated impact protectors and has passed a 1 metre drop test, and it operates from −10 to +50 °C. A 5.7 inch 640 x 480 colour touch screen with adjustable LED backlight is complemented by a membrane keypad, with soft numeric and QWERTY keyboards appearing when text entry is needed. The unit offers five user interface modes: Meter, Calibrator, Data Logger, Documenting Calibrator and Communicator.
Power comes from a rechargeable NiMH battery pack of 4200 mAh at 9.6 V, giving 4 to 8 hours of operation under heavy to normal use. The battery must be charged in a safe area only, and a spare pack can be charged separately and swapped in the field. Pressure is handled by internal Ex modules such as P100m-Ex to P160-Ex and by intrinsically safe external EXT modules, covering ranges from 10 mbar differential up to 1000 bar. The MC6-Ex can also communicate with selected pressure controllers and dry blocks used in a safe area to automate a calibration sequence.
Key Features
The Beamex MC6-Ex combines safety certification with the full capability of a modern documenting calibrator:
- Ex ia IIC T4 Ga certification with ATEX, IECEx and North American approvals allows use in Zone 0, Class I Division 1 locations.
- Pressure uncertainty starts from ±(0.01 % FS + 0.025 % of reading), RTD measurement from ±0.015 °C and current measurement from ±(1 µA + 0.01 % of reading), stated as one-year total uncertainty.
- A traceable, accredited calibration certificate is delivered with every unit, including uncertainty data from the calibration laboratory.
- Multi-bus communicator for HART, FOUNDATION Fieldbus and Profibus PA with built-in loop supply works on all types of smart field instruments, not only pressure and temperature transmitters.
- Five operating modes in one device reduce the equipment a technician must carry into a hazardous area.
- Documenting calibrator mode with Beamex CMX and LOGiCAL software supports a fully digital, paperless calibration flow.
- Additional functions include scaling with square-root transfer for flow, programmable alarm, leak test, damping, step and ramp generation, and custom RTD and pressure units.
- Three-year warranty on the calibrator and a rugged IP65 housing protect the investment in demanding offshore and desert conditions.
Industrial Applications
The MC6-Ex targets offshore and onshore oil and gas platforms, refineries, chemical and petrochemical plants and any facility where flammable gases may be present. It is also used in the pharmaceutical industry, energy production and gas processing. For Omani operators this covers wellhead pads and gathering stations in the interior, process units at Sohar, Duqm and Salalah, LNG-related facilities, and fuel-gas and gas-turbine auxiliary systems in power and desalination plants.
Seven Star LLC helps maintenance and instrument teams choose the pressure module range, communicator protocols and accessories for each plant, and recommends the Beamex MC6-Ex where a calibrator must enter the hazardous area itself. Planners comparing options may also review the Fluke 754 documenting process calibrator or the Druck DPI 620G Genii advanced modular multifunction calibrator for safe-area work. Ask us for the Beamex MC6-Ex datasheet when you need certificate numbers, module lists and temperature class details for the permit-to-work package.
Technical Specifications
Selected specifications for the Beamex MC6-Ex are listed below from the manufacturer brochure. Some functions are optional, so confirm the configuration when ordering.
| Parameter | Specification |
|---|---|
| Model | Beamex MC6-Ex intrinsically safe field calibrator and communicator |
| Ex marking | II 1 G Ex ia IIC T4 Ga, Ta −10 to +50 °C; Class I Zone 0 AEx ia IIC T4 Ga |
| Display | 5.7 inch, 640 x 480 TFT LCD with resistive touch panel |
| Communication protocols | HART, FOUNDATION Fieldbus, Profibus PA |
| Pressure measurement | Internal Ex modules and external IS modules, 10 mbar to 1000 bar |
| Temperature | Two simultaneous RTD or thermocouple channels, measure and simulate |
| Electrical | Voltage, current, resistance, frequency, pulse, switch sensing, loop supply |
| Battery | NiMH 4200 mAh, 9.6 V; 4–8 hours; charge in safe area only |
| Ingress protection | IP65 |
| Weight and size | 2.5–2.9 kg; 207 x 231 x 80 mm |
| Operating temperature | −10 to +50 °C |
| Warranty | 3 years (1 year for battery pack) |
Request a Quote for Beamex MC6-Ex
To request a quotation for the Beamex MC6-Ex, send Seven Star LLC the pressure ranges, communication protocols and accessories you need, together with the hazardous-area zone and gas group. We supply the Beamex MC6-Ex on request with engineering support in Muscat, and we can provide the Beamex MC6-Ex datasheet and certification details to instrumentation and procurement teams across Oman and the GCC.
See also: Beamex EXT External Pressure Modules, 70 kPa to 100 MPa.
Matching an MC6-Ex configuration
Beamex lists the MC6-Ex base calibrator under product code 9250000. For an instrument used in a classified area, identify the site approval and the approved accessories required, then list the pressure ranges and communication options separately.
Datasheets & Documents
- Brochure Beamex MC6-Ex Intrinsically Safe Field Calibrator Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex MC6-Ex Intrinsically Safe Field Calibrator
Answers from our engineering team on installation, compatibility and integration.
01In which hazardous zones can the Beamex MC6-Ex be used?
The MC6-Ex is marked II 1 G Ex ia IIC T4 Ga, which is suitable for Zone 0 and therefore for Zones 1 and 2 as well, with ambient temperature from −10 to +50 degrees C. North American approval is Class I Zone 0 AEx ia IIC T4 Ga and Class I Division 1 Groups A to D.
02Does the Beamex MC6-Ex support HART and fieldbus devices?
Yes. The communicator mode supports HART, FOUNDATION Fieldbus and Profibus PA. Built-in loop power with the correct impedance means no external supply or resistor is needed, and all three protocols can be installed in one unit.
03Can the battery be charged in the hazardous area?
No. The brochure states that charging must be done in a safe area only. A spare battery can be charged separately and replaced in the field, and Bluetooth and USB are also restricted to the safe area.
04How accurate is the Beamex MC6-Ex?
One-year total uncertainty is given as starting from ±(0.01 % FS + 0.025 % of reading) for pressure, ±0.015 degrees C for RTD measurement and ±(1 microamp + 0.01 % of reading) for current. A traceable accredited calibration certificate is supplied with every unit.
05Does Seven Star LLC supply the Beamex MC6-Ex in Oman?
Seven Star LLC supplies genuine Beamex MC6-Ex calibrators to Oman and the GCC, with engineering support in Muscat. We can quote the calibrator with pressure modules and share the manufacturer documents for your permit and procurement files.


















Reviews
There are no reviews yet.