- Automation & ControlView all 2,476 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Motor Soft Starters
- Encoders
- Safety Switches & Guard Locking
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Fluke
Fluke 5502A Multi-Product Calibrator
Description
Overview
Fluke 5502A is a transportable multi-product calibrator engineered for calibration teams that need laboratory-grade accuracy without being tied to a fixed bench location. Beyond the DC/AC voltage, current, resistance, and capacitance functions common to multi-product calibrators, the Fluke 5502A adds full thermocouple and RTD temperature simulation, covering B, C, E, J, K, L, N, R, S, T, and U type thermocouples plus multiple Pt385, Pt3926, Cu427, and PtNi120 RTD curves, making it a genuine one-box solution for electrical and temperature calibration labs alike.
With fast quotation turnaround and technical support, Seven Star LLC supplies the Fluke 5502A to calibration laboratories and process instrumentation teams across Oman and the GCC, with technical application support for labs standardizing electrical and temperature traceability under one accredited program.
Operating Principle
The Fluke 5502A combines a precision DC/AC signal-generation stage with a dedicated thermocouple and RTD emulation circuit, so the same chassis can source a stable voltage or current on one test and emulate the millivolt output of a Type K thermocouple or the resistance curve of a Pt100 RTD on the next, without external cold-junction compensation hardware. Internal cold-junction sensing corrects the simulated thermocouple output automatically, which is what allows the unit to hold traceable accuracy when used away from a controlled lab environment — a capability that matters for teams calibrating field transmitters in situ rather than pulling every device back to a central lab.
On the electrical side, closed-loop feedback regulation maintains DC voltage to ±1020V, AC voltage from 1 mV to 1020V across 10 Hz to 500 kHz, current to 20.5A (extendable to 120A AC with the optional 52120A transconductance amplifier), resistance to 1100 MΩ, and capacitance from 220 pF to 110 mF. The practical consequence is that one calibrator, one set of traceability certificates, and one technician can cover the electrical and temperature verification of a mixed instrument population — multimeters, RTD transmitters, thermocouple readouts, and process indicators — in a single site visit.
Engineering Design of the Fluke 5502A
The Fluke 5502A is built into a ruggedized, ergonomically handled enclosure specifically designed for transport between calibration sites, with removable access doors that expose the rear connection panel for field servicing without full disassembly. Dual backlit alphanumeric displays present the source value on one screen and reference/error readout on the other, letting a technician confirm as-found and as-left readings side by side during an as-found/as-left calibration procedure.
Input and output terminals are grouped by function — normal 4-wire voltage/current binding posts, auxiliary sense terminals, a dedicated thermocouple/RTD terminal block, and a BNC scope-output connector for the optional 300 MHz or 600 MHz oscilloscope calibration module — keeping wiring changes fast during multi-function test sequences. RS-232 and IEEE 488 (GPIB) interfaces are both provided as standard, giving labs a choice of legacy GPIB-based automated test systems or simpler serial control scripts.
Key Features
The Fluke 5502A pairs electrical sourcing with temperature simulation in a single transportable chassis. Its principal capabilities include:
- Sources DC voltage to ±1020V and AC voltage from 1 mV to 1020V across 10 Hz to 500 kHz for wideband voltmeter calibration.
- Delivers DC and AC current to 20.5A, extendable to 120A AC with the optional 52120A transconductance amplifier for high-current clamp meter work.
- Simulates eleven thermocouple types (B, C, E, J, K, L, N, R, S, T, U) with automatic internal cold-junction compensation for field-accurate temperature calibration.
- Sources RTD resistance curves across multiple Pt385, Pt3926, Cu427, and PtNi120 configurations for verifying RTD transmitters and readouts.
- Generates resistance to 1100 MΩ and capacitance from 220 pF to 110 mF for ohmmeter and capacitance meter verification.
- Offers optional 300 MHz or 600 MHz oscilloscope calibration for labs that also maintain bench and field oscilloscopes.
- Communicates over both RS-232 and IEEE 488 (GPIB), supporting legacy automated calibration systems as well as modern scripted control.
- Ships in a transportable, ergonomically handled enclosure with removable access doors built for repeated on-site calibration visits.
Industrial Applications
In Oman’s oil and gas production facilities, power generation plants, and district cooling networks, calibration technicians rely on the Fluke 5502A to verify both the electrical instrumentation and the temperature transmitters distributed across a single process unit without swapping calibrators between tasks. Its combined electrical and thermocouple/RTD capability is particularly valuable for turnaround and shutdown work at refineries and petrochemical complexes, where hundreds of temperature and electrical loops must be verified within a tight maintenance window. The transportable enclosure suits field calibration teams serving desalination plants, cement works, and marine terminals across the Sohar and Salalah industrial zones, where equipment cannot always be pulled offline and shipped to a central laboratory.
With engineering support in Muscat, Seven Star LLC supplies the Fluke 5502A to calibration laboratories and industrial end users throughout the Sultanate of Oman, Muscat, and the wider GCC, supporting hospital biomedical engineering departments, hospitality-chain facilities teams, and pharmaceutical manufacturers that all depend on accredited temperature and electrical calibration for compliance. Seven Star LLC’s technical support helps calibration teams in Sohar, Salalah, and Muscat specify and source a 5502A, with lead time confirmed at quotation.
Technical Specifications
The table below summarizes the primary specifications of the Fluke 5502A relevant to calibration lab and field-service procurement.
| Parameter | Specification |
|---|---|
| Model | Fluke 5502A |
| DC Voltage | 0 to ±1020V |
| AC Voltage | 1 mV to 1020V, 10 Hz–500 kHz |
| DC Current | 0 to 20.5A |
| AC Current | 29 µA to 20.5A (to 120A with 52120A), 10 Hz–30 kHz |
| Resistance | 0 to 1100 MΩ |
| Capacitance | 220 pF to 110 mF |
| Thermocouple Types | B, C, E, J, K, L, N, R, S, T, U |
| RTD Types | Pt385, Pt3926, Cu427, PtNi120 (multiple curves) |
| Oscilloscope Calibration (optional) | 300 MHz or 600 MHz |
| Interfaces | RS-232, IEEE 488 (GPIB) |
| Enclosure | Transportable, ergonomic carry handles, removable access doors |
Request a Quote for Fluke 5502A Multi-Product Calibrator
Seven Star LLC invites calibration laboratories, process instrumentation teams, and field-service divisions across Oman and the GCC to submit a formal RFQ for the Fluke 5502A Multi-Product Calibrator. Seven Star LLC supplies on request with lead time confirmed at quotation, provides the full technical datasheet on request, and connects buyers directly with its instrumentation division for application guidance and GPIB/RS-232 integration support — contact Seven Star LLC today to place an order or request a tailored quotation.
Browse the full Fluke range or see more Portable Test & Measurement products supplied by Seven Star LLC in Oman and the GCC.
Datasheets & Documents
- Datasheet Fluke 5502A Multi-Product Calibrator Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 5502A Multi-Product Calibrator
Answers from our engineering team on installation, compatibility and integration.
01What makes the Fluke 5502A different from a standard electrical calibrator?
The Fluke 5502A adds full thermocouple and RTD temperature simulation to standard DC/AC voltage, current, resistance, and capacitance sourcing, so one instrument can calibrate both electrical meters and temperature transmitters without separate reference sources.
02Can the Fluke 5502A be used for on-site field calibration?
Yes. The 5502A ships in a ruggedized, ergonomically handled enclosure with removable access doors, and its internal cold-junction compensation keeps thermocouple simulation accurate even outside a controlled lab environment, making it well suited to field calibration visits.
03Which thermocouple and RTD types does the Fluke 5502A support?
The 5502A simulates eleven thermocouple types (B, C, E, J, K, L, N, R, S, T, U) and multiple RTD curves including Pt385, Pt3926, Cu427, and PtNi120, covering the great majority of temperature transmitters and readouts found in industrial process plants.
04Does the Fluke 5502A support legacy GPIB-based calibration systems?
Yes. The 5502A includes both RS-232 and IEEE 488 (GPIB) interfaces as standard, allowing it to integrate with existing legacy automated calibration systems as well as newer serial-based scripted control setups.
05Is Seven Star LLC an experienced supply partner for Fluke products?
Yes. Seven Star LLC is an experienced supplier of Fluke in Oman and the GCC, supplying instruments including the 5502A along with technical support.


















Reviews
There are no reviews yet.