Tecfluid Series 2000 Variable Area Flowmeter
Overview
The Tecfluid Series 2000 Variable Area Flowmeter is a compact, short-mounting-length instrument purpose-built for low flow rate measurement of gas and liquid in control panel installations. Operating on the variable area principle, a float moves within a tapered borosilicate glass tube to indicate flow rate directly on a calibrated scale, offering a simple, reliable, power-free measurement solution for applications ranging from pilot plants to industrial refrigeration systems.
Seven Star LLC supplies the Tecfluid Series 2000 as an authorized partner to control panel builders, water treatment facilities, and process industries across Oman and the GCC. Every flowmeter shipped through Seven Star LLC is genuine Tecfluid equipment, backed by full manufacturer warranty and local technical support for installations in Muscat, Sohar, and Salalah.
Measurement and Operating Principle
The Series 2000 operates on the classic variable area measurement principle: as fluid flows upward through the tapered borosilicate glass tube, a float rises to a position where the annular gap between the float and tube wall creates a pressure differential balanced by the float’s weight, with the float position directly indicating flow rate on a calibrated scale marked in l/h, l/min, percent, or other engineering units. Vertical mounting with upward flow and rear connections allows compact installation directly onto control panels without requiring straight pipe runs before or after the flowmeter.
An integrated needle valve provides accurate manual flow regulation as standard, with a valve-free version available for applications where flow is regulated elsewhere in the system. Optional adjustable limit switches – optical detector, inductive sensor, or reed switch – enable the Series 2000 to provide both visual indication and electrical alarm or control signals from the same compact body.
Engineering Design of the Tecfluid Series 2000
The Series 2000 family spans four model variants to match application accuracy and connection requirements: the 2100 model offers ±3.5% full-scale accuracy with 1/4in BSP or NPT connections, the 2150 model improves to ±3% full-scale accuracy on the same connection size, and the higher-precision 2300 and 2340 models achieve ±1.6% full-scale accuracy, with the 2340 offering larger 1/2in or 3/4in male BSP or NPT connections for higher flow capacity applications.
Wetted parts are constructed from EN 1.4404 (AISI 316L) stainless steel for corrosion resistance, with the float available in 316L stainless steel, glass, plastic, or ceramic depending on the process fluid and required response characteristics. Measuring ranges span from 0.1 l/h to 1000 l/h for water and 1 Nl/h to 30 Nm3/h for air, covering the low-flow measurement needs typical of pilot plants, gas burner control, and osmosis water purification systems. ATEX-certified variants are available for hazardous-area installations.
Key Features
- Variable area measurement principle with borosilicate glass tapered tube
- Compact, short mounting length ideal for control panel installation
- Integrated needle valve for accurate manual flow regulation
- Four model variants (2100/2150/2300/2340) covering ±1.6% to ±3.5% accuracy
- Measuring range 0.1–1000 l/h (water) or 1 Nl/h–30 Nm3/h (air)
- 316L stainless steel wetted parts with glass, plastic, or ceramic float options
- Optional adjustable limit switches (optical, inductive, or reed)
- ATEX-certified variants for hazardous-area installations
Industrial Applications
The Series 2000 is widely used across Oman’s industrial and utility sectors for control panel flow indication, pilot plant measurement, and control of gas burners in industrial and process refrigeration and treatment ovens. Its compact form factor and needle-valve flow regulation make it a practical choice for machinery-mounted flow control and water purification systems including reverse osmosis skids common in Muscat and Sohar utility installations.
As an authorized Tecfluid partner, Seven Star LLC supports panel builders and process facilities across Oman and the GCC with genuine Series 2000 flowmeters correctly specified for the target fluid, flow range, and accuracy class. This authorized-partner relationship ensures reliable low-flow measurement backed by manufacturer warranty and responsive local technical support.
Technical Specifications
| Model | Tecfluid Series 2000 (2100 / 2150 / 2300 / 2340) |
|---|---|
| Measurement Principle | Variable area (float in tapered glass tube) |
| Measuring Range | 0.1–1000 l/h (water), 1 Nl/h–30 Nm3/h (air) |
| Accuracy | ±3.5% f.s. (2100) to ±1.6% f.s. (2300/2340) |
| Connections | 1/4in BSP/NPT (2100/2150/2300); 1/2in or 3/4in BSP/NPT (2340) |
| Flow Tube Material | Borosilicate glass |
| Wetted Parts | EN 1.4404 (AISI 316L) stainless steel |
| Float Material | 316L stainless steel, glass, plastic, or ceramic |
| Options | Needle valve regulation, adjustable limit switches, ATEX certification |
Why Choose Seven Star LLC for Tecfluid Variable Area Flowmeters
A variable area flowmeter’s simplicity is genuinely useful, but only when tube material, float type, and scale range are correctly matched to the specific low-flow application, since an oversized tube reads inaccurately at the bottom of its range where many dosing and utility monitoring points actually operate. Seven Star LLC confirms the correct Series 2000 tube size, float, and accuracy class against your real flow range before order confirmation, drawing on our authorized Tecfluid partnership across Oman and the wider GCC. We also support utility and process monitoring points across Muscat, Sohar, and Salalah with spare float and seal kit planning, keeping simple mechanical flow indication reliable without waiting on international parts sourcing for routine maintenance, and our team can advise on glass versus metal tube construction where process visibility or overpressure protection is the deciding factor.
Contact Seven Star LLC today to order the genuine Tecfluid Series 2000 Variable Area Flowmeter with full manufacturer warranty, correctly specified accuracy class, and expert technical support for low-flow measurement projects across Oman and the GCC.
Related Products
- Honeywell VersaFlow Coriolis Mass Flow Meter
- Yokogawa ADMAG AXG Electromagnetic Flowmeter
- ABB BC36164-12 Glass Tube Variable-Area Flowmeter
- ABB 1330L Integral Orifice Flow Element
- Endress+Hauser Promass 80F Coriolis Mass Flowmeter
- ABB-Armored variable area purgemeter FAM3200
- Titan Enterprises OG3 Oval Gear Flow Meter
Tecfluid S.A. is a Spanish manufacturer of industrial flow and level measurement equipment, offering robust instruments for accurate fluid level and flow detection in demanding process environments. The company’s product range includes magnetic level gauges, bypass level transmitters, flowmeters, variable area and electromagnetic flow devices, as well as accessories and automation interface options. Tecfluid solutions are engineered to withstand high pressure, high temperature and corrosive conditions, serving sectors such as chemical, petrochemical, marine, energy, boiler systems and storage installations where reliable fluid monitoring and control are essential.




































Reviews
There are no reviews yet.