Brand:

KROHNE OPTIMASS 6400 Coriolis Mass Flowmeter

Description

Overview

KROHNE OPTIMASS 6400 is a high-performance Coriolis mass flowmeter engineered for demanding process applications where cryogenic media, high temperature, high pressure, or entrained gas would defeat a conventional Coriolis meter. Built around a twin bent tube sensor combined with the KROHNE MFC 400 signal converter, the OPTIMASS 6400 is the first Coriolis mass flowmeter to feature Entrained Gas Management (EGM), delivering continuous, accurate measurement even with gas entrainment up to 100% of volume – a capability that keeps custody transfer, LNG, and cryogenic operations running without the false readings or dropouts common to standard mass flow sensors.

Backed by manufacturer datasheet documentation, Seven Star LLC proudly supplies the OPTIMASS 6400 Coriolis mass flowmeter to petrochemical, oil and gas, and food and beverage customers across Oman and the wider GCC. Every unit supplied through Seven Star LLC comes with manufacturer documentation and access to local technical support, helping facility engineers and procurement teams in Muscat, Sohar, and Salalah receive a correctly specified instrument.

Measurement Principle

The KROHNE OPTIMASS 6400 measures mass flow directly using the Coriolis effect. Process fluid is routed through the sensor’s twin bent measuring tubes, which are driven into oscillation at their natural resonant frequency. As fluid moves through the vibrating tubes, the Coriolis force induces a phase shift between the tube’s inlet and outlet sections that is directly proportional to mass flow rate, while the resonant frequency itself shifts in relation to fluid density. Because this measurement is derived from the physical mass of the fluid rather than its volume, the OPTIMASS 6400 delivers mass flow, density, volume flow, and concentration from a single sensor, independent of temperature, pressure, or fluid composition changes.

What sets the KROHNE OPTIMASS 6400 apart is its Entrained Gas Management (EGM) capability. In conventional Coriolis sensors, relative movement between gas bubbles and liquid dampens the tube’s oscillation amplitude and interferes with the electronics’ ability to determine the true resonant frequency, causing measurement dropout. EGM continuously adapts the tube driver oscillation to follow varying fluid conditions, maintaining a real measured reading together with a configurable alarm that flags transient gas entrainment – turning what would be a process disruption on other meters into actionable diagnostic information.

Engineering Design of the KROHNE OPTIMASS 6400

The OPTIMASS 6400 sensor uses a twin bent tube design available in 316L stainless steel, Hastelloy C-22, or Duplex UNS S31803, in sizes from DN08 to DN100 (with DN150 to DN250 available). This construction supports operating temperatures from -200°C to +400°C (-328°F to +752°F) and pressures up to 200 bar / 2900 psig, covering everything from cryogenic LNG transfer to high-temperature process duties within one meter platform. The sensor is self-draining when mounted vertically and is available with optional heat tracing, purge ports, and insulation or heating jackets for temperature-sensitive products.

Paired with the KROHNE MFC 400 signal converter – available in compact or remote mount configurations – the OPTIMASS 6400 supports HART, FOUNDATION Fieldbus, Modbus, and PROFIBUS communication, along with secure wireless Bluetooth access for commissioning, verification, and diagnostics without opening the enclosure. An extensive onboard diagnostics package continuously monitors medium temperature, density, concentration, and driver amplitude, flagging installation errors or process changes as they occur rather than after the fact.

Key Features

The KROHNE OPTIMASS 6400 Coriolis mass flowmeter combines extreme-condition durability with measurement intelligence that few mass flow sensors can match, which is why the KROHNE OPTIMASS 6400 remains a preferred choice for demanding custody transfer and cryogenic applications.

  • Entrained Gas Management (EGM) maintains continuous, accurate mass flow measurement even with gas entrainment up to 100% of volume.
  • The twin bent tube sensor operates across an exceptional range from -200°C to +400°C, covering cryogenic LNG and high-temperature process duties from one platform.
  • Pressure capability up to 200 bar / 2900 psig supports demanding custody transfer and oil and gas transport applications.
  • Sensor materials include 316L stainless steel, Hastelloy C-22, and Duplex UNS S31803 for compatibility with corrosive and abrasive process fluids.
  • A single sensor simultaneously measures mass flow, density, volume flow, and concentration without additional instrumentation.
  • Secure wireless Bluetooth access enables commissioning, verification, and diagnostics without interrupting the process or opening the enclosure.
  • Multi-protocol communication via HART, FOUNDATION Fieldbus, Modbus, and PROFIBUS simplifies integration into existing control systems.
  • The optimized flow splitter design minimizes pressure loss while the self-draining vertical mounting orientation supports hygienic and food-grade process requirements.

Industrial Applications

Process engineers across the region specify the KROHNE OPTIMASS 6400 because it is deployed across petrochemical process control, custody transfer filling and transport measurement in oil and gas, concentration measurement in food and beverage production, and cryogenic LNG handling wherever accurate, entrained-gas-tolerant mass flow measurement is essential. Its wide temperature and pressure envelope also makes it well suited to hydraulics flow, boiler feedwater, and general process industries where fluid conditions vary significantly during operation.

Working closely with plant engineers in the region, Seven Star LLC distributes the OPTIMASS 6400 to refineries, petrochemical complexes, and industrial gas terminals throughout Oman and the GCC. The flowmeter is a strong fit for the custody transfer and process metering needs of the Sohar and Salalah economic zones, as well as for LNG and industrial gas facilities across the region that require dependable mass flow data even under high entrained gas or extreme temperature conditions.

Technical Specifications

The table below summarizes the core specifications of the KROHNE OPTIMASS 6400 Coriolis mass flowmeter, giving buyers of the KROHNE OPTIMASS 6400 a single reference for sizing and material selection.

Parameter Specification
Model KROHNE OPTIMASS 6400
Measuring Principle Coriolis mass flow (twin bent tube)
Signal Converter KROHNE MFC 400 (compact or remote mount)
Nominal Diameter Range DN08 – DN100 (DN150 – DN250 pending)
Sensor Materials 316L Stainless Steel, Hastelloy C-22, Duplex UNS S31803
Process Temperature -200°C to +400°C (-328°F to +752°F)
Process Pressure Up to 200 bar / 2900 psig
Special Capability Entrained Gas Management (EGM) up to 100% gas volume
Communication HART, FOUNDATION Fieldbus, Modbus, PROFIBUS, Bluetooth
Measured Parameters Mass flow, density, volume flow, concentration, temperature
Typical Applications Custody transfer, oil & gas, LNG/cryogenic, petrochemical, food & beverage

Request a Quote for KROHNE OPTIMASS 6400 Coriolis Mass Flowmeter

Ordering the KROHNE OPTIMASS 6400 through Seven Star LLC is straightforward: our team supports the full procurement cycle for the KROHNE OPTIMASS 6400 Coriolis mass flowmeter, from formal RFQ submission to availability and lead-time confirmation, technical datasheet delivery, and direct consultation with our instrumentation division on sensor sizing, material selection, and converter configuration for your application. With fast quotation turnaround and technical support, we supply every OPTIMASS 6400 flowmeter on request with manufacturer documentation and dependable local technical support. Contact Seven Star LLC today to request a quotation or discuss your mass flow measurement project.

Related Products

Datasheets & Documents
  • PDF Datasheet KROHNE OPTIMASS 6400 Coriolis Mass Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

KROHNE is the German flow and level measurement company founded in Duisburg in 1921 as Ludwig Krohne & Sohn. Its first customers were Ruhr steel producers, for whom it built variable area flowmeters. KROHNE dates the first electromagnetic flowmeter for industrial process measurement to 1952. It is still family-owned and headquartered in Duisburg.

Seven Star LLC is an independent supplier in Muscat. We list KROHNE electromagnetic, Coriolis, ultrasonic and variable area flowmeters, radar level transmitters and flow computers, and supply them to water utilities, oil and gas and process plants in Oman and the GCC by order code.

KROHNE company profile

Established 1921, Duisburg, Germany, as Ludwig Krohne & Sohn
Early products Variable area flowmeters for hardening furnaces in the Ruhr steel industry
Milestone 1952: first electromagnetic flowmeter for industrial process measurement, according to KROHNE
Product families Electromagnetic, Coriolis, ultrasonic, vortex and variable area flowmeters, radar and guided radar level, flow computers and metering systems, analysers

Milestones

  • 1921: Ludwig Krohne starts making variable area flowmeters in Duisburg for hardening furnaces in the Ruhr steel industry.
  • 1952: First electromagnetic flowmeter for industrial process measurement, according to KROHNE.
  • 1980: First ultrasonic flowmeter delivered to Shell for crude oil measurement.
  • 1985: Development and production of Coriolis mass flowmeters begins.
  • 1994: First Coriolis mass flowmeter with a single straight measuring tube.
  • 1996: ALTOSONIC V, the first ultrasonic meter for custody transfer of liquids.

KROHNE products we list

Family Models Typical use
Electromagnetic flowmeters OPTIFLUX 2000, 2100, 2300, 4100, 4300, WATERFLUX 3070, 3100, 3300 Water networks, wastewater, seawater intake and conductive process liquids
Coriolis mass flowmeters OPTIMASS 1400, 6400 Direct mass flow and density of hydrocarbons, chemicals and LPG
Ultrasonic flowmeters ALTOSONIC V12, OPTISONIC 3400, 6300 clamp-on, 7300 gas Gas custody transfer, liquid process flow and non-intrusive clamp-on checks
Variable area flowmeters H250 M40, DK800/R Simple, power-free flow indication for purge, sample and utility lines
Level OPTIFLEX 7200 guided radar, OPTIWAVE 5400, 7500, 1540, OPTISWITCH 5300 Level in tanks, separators and chemical storage, and point level switching
Flow computer SUMMIT 8800 Fiscal and custody transfer calculations for gas and liquid metering

The flowmeter principle follows the medium. Electromagnetic meters need a conductive liquid, have no moving parts and no pressure loss, and suit water and slurries. Coriolis meters measure mass flow and density directly, so they work for hydrocarbons and non-conductive liquids. Ultrasonic meters handle gas and large pipes, and multi-path designs such as the ALTOSONIC V12 are used for custody transfer. Variable area meters need no power at all and give a simple local reading.

Where KROHNE instruments are used

In Oman and the GCC, KROHNE flowmeters and level transmitters are used in water transmission and distribution, desalination, wastewater, oil and gas production and fiscal metering, refineries, petrochemical and chemical plants, and power stations.

Ordering KROHNE instruments: what we need

Send the complete KROHNE order code or the nameplate data. For a new meter, send the medium, the flow range, pressure and temperature, the pipe size and flange rating, the liner and electrode materials (for electromagnetic meters), the output and communication, and the hazardous area classification.

Facts checked against KROHNE company history (100th anniversary), October 2026.

Frequently Asked Questions

What is Entrained Gas Management (EGM) on the KROHNE OPTIMASS 6400?
EGM is a KROHNE technology that allows the OPTIMASS 6400 to continue delivering an accurate mass flow reading even when the process fluid contains entrained gas up to 100% of volume. Conventional Coriolis meters lose measurement under these conditions because gas bubbles dampen the tube oscillation, but the OPTIMASS 6400 adapts the driver signal to maintain a real reading and raises a configurable alarm when entrainment occurs.
Can the OPTIMASS 6400 handle cryogenic media like LNG?
Yes. The OPTIMASS 6400 is rated for process temperatures down to -200°C (-328°F), which covers liquefied natural gas and other cryogenic applications, in addition to high-temperature duties up to +400°C (+752°F) within the same sensor platform.
What sensor materials and sizes are available for the OPTIMASS 6400?
The sensor is offered in 316L stainless steel, Hastelloy C-22, and Duplex UNS S31803, with nominal sizes from DN08 to DN100, and larger sizes from DN150 to DN250 available on request, allowing selection to match both the process fluid and the required flow capacity.
Is the OPTIMASS 6400 suitable for custody transfer applications?
Yes. The OPTIMASS 6400 twin bent tube design delivers the accuracy and repeatability required for custody transfer filling and transport measurement in the oil and gas industry, and its EGM capability protects measurement integrity even when gas entrainment would otherwise compromise fiscal metering accuracy.
Is Seven Star LLC an experienced supply partner for KROHNE products?
Yes, Seven Star LLC is an experienced supplier of KROHNE in Oman and the GCC. We supply KROHNE instrumentation with calibration documentation and local technical support.