Schneider Electric TM3DI16G Modicon TM3 16 Input Module

Description

TM3DI16G: TM3 16-input digital module with spring terminals

The TM3DI16G is a Modicon TM3 digital input module with sixteen 24 V DC inputs that work in sink or source wiring. It adds a block of field inputs to a Modicon M221, M241, M251 or M262 controller through the TM3 expansion bus, in a case only 27.4 mm wide and with pluggable spring terminals.

Within the TM3 input family it is the general-purpose 16-point choice: more inputs per slot than TM3DI8G and spring terminals in contrast to the HE-10 connector of TM3DI16K. Seven Star LLC supplies the this unit in Oman and the GCC as an independent supplier based in Muscat.

The TM3DI16G compared with other TM3 input modules

Reference Inputs Connection Width Input data
TM3DI16G 16 inputs Spring, 10 x 1.5 mm² 27.4 mm Type 3, 7 mA
TM3DI16K 16 inputs HE-10 connector 21.4 mm 5 mA, 4.4 kΩ
TM3DI8G 8 inputs 11 x 2.5 mm² (screw per datasheet) 27.4 mm Type 1, 7 mA

Technical specifications of the TM3DI16G

Parameter Specification
Manufacturer / part number Schneider Electric / TM3DI16G
Range of product Modicon TM3
Product type Discrete input module
Discrete inputs 16, 24 V DC, sink or source (IEC 61131-2 Type 3)
Input current 7 mA
State 1 / state 0 15–28.8 V DC and at least 2.5 mA / 0–5 V DC and at most 1 mA
Input impedance 3.4 kΩ
Response time 4 ms maximum, turn-on and turn-off
Sensor supply 19.2–28.8 V
Isolation 500 V AC between channels and bus
Reliability MTBF 250 years at 40 °C
Bus consumption 34 mA at 5 V DC
Terminals 10 x 1.5 mm² removable spring, pitch 3.81 mm; 0.14–1.5 mm² (26–16 AWG)
Cable length Unshielded, 50 m maximum
Dimensions (W x H x D) 27.4 x 90 x 84.6 mm
Net weight 0.1 kg
Compatible controllers Modicon M221, M241, M251, M262
Mounting 35 mm DIN rail (TH35-15, TH35-7.5) or panel with fixing kit
Operating temperature −10 to 55 °C horizontal; −10 to 35 °C vertical
Storage temperature −25 to 70 °C
Humidity 10–95 % without condensation
Protection IP20
Certifications listed CE, cULus, UKCA, RCM, EAC, cULus HazLoc
Shock / vibration 15 gn for 11 ms; 3.5 mm at 5–8.4 Hz and 3 gn at 8.4–150 Hz

Sensor supply and wiring of the TM3DI16G

A sensor supply range of 19.2 to 28.8 V is listed, which means the field supply must stay inside this window. Terminals are ten removable 1.5 mm² spring clamps at 3.81 mm pitch accepting 0.14 to 1.5 mm² (26 to 16 AWG) solid conductor. Unshielded input cables can be up to 50 m long.

Because sink and source wiring are both allowed, the common terminals can be wired to 0 V or 24 V to suit PNP or NPN sensors; just keep one convention across the module.

Selection checklist and RFQ details for the TM3DI16G

Check before ordering:

  • 16 channels at 24 V DC are needed and Type 3 characteristics are acceptable
  • spring terminals and 1.5 mm² wire fit the site standard
  • the controller family has spare TM3 positions
  • the sensor supply stays within 19.2 to 28.8 V

Send quantity, controller model and delivery location with your RFQ.

Bus load and isolation of the TM3DI16G

The module draws 34 mA at 5 V DC from the expansion bus and is isolated from it by 500 V AC between channels and bus. A green LED per channel shows the input status, which is the first diagnostic when a sensor or switch is suspected.

Reliability is quoted as an MTBF of 250 years at 40 °C, a useful figure for maintenance planning.

Typical uses of the TM3DI16G in the GCC

Sixteen-input blocks collect limit switches, valve position feedback, motor status contacts, level switches and operator pushbuttons in pump stations, water treatment plants, utility buildings and packaged machines. Spring terminals help installers who work in confined, hot cabinets where tightening screws is slow.

Certifications listed include CE, cULus, UKCA, RCM, EAC and cULus HazLoc.

During commissioning, switch each field device in turn and watch the channel LED and the controller variable together; a mismatch usually points to a polarity or common-terminal wiring error. Label the terminal rows clearly before closing the panel, because sixteen similar-looking inputs are easy to confuse during later fault finding.

Mounting and environment of the TM3DI16G

The module is 27.4 mm wide, 90 mm high and 84.6 mm deep and weighs 0.1 kg. It snaps onto a 35 mm DIN rail or is fixed on a panel with the kit. Operating limits are −10 to 55 °C horizontal and −10 to 35 °C vertical, humidity is 10 to 95 % without condensation, and protection is IP20.

Vibration withstand is 3.5 mm at 5–8.4 Hz and 3 gn at 8.4–150 Hz, and shock withstand is 15 gn for 11 ms.

Input characteristics of the TM3DI16G

Each input draws 7 mA at 24 V DC and has an impedance of 3.4 kΩ. The datasheet states conformity to IEC 61131-2 Type 3 for all sixteen channels, with a guaranteed state 1 between 15 and 28.8 V DC (at least 2.5 mA) and a guaranteed state 0 between 0 and 5 V DC (at most 1 mA). Response time is 4 ms for both turn-on and turn-off.

Type 3 inputs tolerate the leakage of two-wire proximity sensors better than Type 1, but they still need a clean 24 V supply. The module is not intended for fast pulse counting; use the controller fast inputs for that.

Documents and quotation

The Schneider Electric datasheet for the this unit is attached on this page, so you can compare the listed values with your design before ordering.

To request a quotation for the TM3DI16G, send the quantity, delivery destination and any project reference through the RFQ form. Seven Star LLC supplies Schneider Electric automation products in Oman and the GCC as an independent supplier based in Muscat, and we confirm stock status and lead time against your request.

Other Models in the Se Tm3 Di Range

Seven Star LLC supplies models from the Se Tm3 Di range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric TM3DI16G Modicon TM3 16 Input ModuleLogic ControllersYou are viewing this model
Schneider Electric TM3DI16K Modicon TM3 16 Input HE10 ModuleLogic ControllersView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric TM3DI16G Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric TM3DI16G Modicon TM3 16 Input

Answers from our engineering team on installation, compatibility and integration.

01How many inputs does the TM3DI16G have?
Sixteen 24 V DC inputs, sink or source, conforming to IEC 61131-2 Type 3.
02What is the response time of the TM3DI16G?
4 ms maximum for both turn-on and turn-off.
03What terminals does the TM3DI16G use?
Ten removable 1.5 mm² spring terminals at 3.81 mm pitch.
04How much bus current does the TM3DI16G use?
34 mA at 5 V DC from the expansion bus. See the datasheet linked on this page for the full figures.
05What size is the TM3DI16G?
27.4 mm wide, 90 mm high and 84.6 mm deep, with a net weight of 0.1 kg.