Schneider Electric TM241C24T Modicon M241 24 I/O Controller
Description
TM241C24T: Modicon M241 24-I/O transistor logic controller
The TM241C24T is a Modicon M241 logic controller built for machine control. It carries 24 built-in I/O points, fourteen 24 V DC inputs and ten transistor outputs, and offers four high-speed counting inputs, four pulse-train outputs, two serial ports and USB. This version has no Ethernet port.
The M241 is a step above the M221 in processing power and motion capability. The TM241C24T is the basic member of the three-reference group on this site: it keeps the 24-point I/O layout but leaves out the Ethernet interface found on TM241CE24T and TM241CE24U. Seven Star LLC supplies the TM241C24T in Oman and the GCC as an independent supplier based in Muscat.
Memory, tasks and timing of the TM241C24T
The controller has 64 MB of system RAM and 128 MB of built-in flash for the user program, with an optional SD card up to 16 GB. Execution time is 0.3 ms for 1 K instructions in an event or periodic task and 0.7 ms for other instructions. The task structure offers up to four cyclic master tasks (or three plus a freewheeling task), eight event tasks and eight external event tasks.
A battery of type BR2032 with a life of four years keeps data and the clock, with two years of backup at 25 °C once the supply is removed. Clock drift is 60 s per month or less at 25 °C, so periodic synchronisation is advisable for time-stamped logging.
Technical specifications of the TM241C24T
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / TM241C24T |
| Range of product | Modicon M241 |
| Product type | Logic controller |
| Rated supply voltage | 24 V DC, limits 20.4–28.8 V; inrush 50 A |
| Power consumption | 32.6–40.4 W with maximum expansion |
| Discrete inputs | 14 at 24 V DC, 8 of them fast; sink or source |
| Discrete outputs | 10 transistor, 24 V DC, 0.5 A, positive logic (source); 4 fast outputs |
| Fast input counting | 4 fast inputs (HSC) up to 200 kHz; A/B at 100 kHz |
| Pulse outputs | PTO on 4 channels at 100 kHz; PWM up to 20 kHz |
| Expansion | 7 local or 14 remote TM3 modules |
| Memory | 64 MB system RAM; 128 MB flash for user programs |
| Removable storage | SD card up to 16 GB (optional) |
| Real-time clock | Built in; drift 60 s/month or less at 25 °C |
| Battery | BR2032 lithium, 4 years life, 2 years backup at 25 °C |
| Serial and USB | Serial 1 RJ45 RS232/RS485; serial 2 screw terminal RS485; mini-B USB |
| Mounting | 35 mm DIN rail (TH35-15, TH35-7.5) or panel with kit |
| Dimensions (W x H x D) | 150 x 90 x 95 mm |
| Net weight | 0.53 kg |
| Operating temperature | −10 to 55 °C horizontal; −10 to 50 °C vertical |
| Storage temperature | −25 to 70 °C |
| Humidity | 10–95 % without condensation |
| Protection | IP20 with protective cover in place |
| Shock resistance | 15 gn for 11 ms |
| Certifications listed | cULus, CE, UKCA, RCM, DNV-GL, ABS, LR |
Selection checklist and RFQ details for the TM241C24T
Check these points before ordering:
- that 14 inputs and 10 outputs cover the I/O list with reserve
- whether the machine needs Ethernet, which this reference does not provide
- output wiring: this model uses source transistors, whereas TM241CE24U uses sink
- the number of pulse axes and fast counters required
- spare capacity on the 24 V supply for 50 A inrush
Send the quantity, delivery site and software version used for programming with your request.
The TM241C24T against its Ethernet siblings
The table compares the three M241 24-point references.
| Reference | Ethernet port | 24 V outputs | Ports |
|---|---|---|---|
| TM241C24T | No | Transistor source | Serial x2, USB |
| TM241CE24T | Yes, 10/100 | Transistor source | Serial x2, USB, Ethernet |
| TM241CE24U | Yes, 10/100 | Transistor sink | Serial x2, USB, Ethernet |
Installing the TM241C24T
The housing is 150 mm wide, 90 mm high and 95 mm deep and weighs 0.53 kg. Mount it on a 35 mm DIN rail or on a panel with the fixing kit. Terminal blocks for inputs, outputs and the 24 V DC supply are removable screw types at 5.08 mm pitch. Inrush current is 50 A, higher than the M221, so check the 24 V supply and its protective device.
Orientation affects the temperature rating: −10 to 55 °C horizontal and −10 to 50 °C vertical. Cable limits are 50 m unshielded for inputs and outputs, 10 m shielded for fast inputs and 3 m shielded for fast outputs.
Serial and USB links of the TM241C24T
Serial 1 is an RJ45 connector for RS232 or RS485 and can supply 5 V at up to 200 mA. Serial 2 is a removable screw terminal block, RS485 only. A mini-B USB 2.0 port serves programming and download. The datasheet lists Modbus master/slave on the serial lines, with rates from 1.2 to 115.2 kbit/s.
For a plant with several serial devices (VFDs, meters, remote I/O) two ports allow a clean split between the field bus and a supervisory link. If a plant network is needed instead, choose the Ethernet versions.
Inputs, outputs and fast functions of the TM241C24T
Fourteen inputs at 24 V DC are fitted, with eight of them fast inputs that respond in 2 µs or less. Four fast inputs can count at up to 200 kHz in single-phase or pulse/direction mode, or at 100 kHz in A/B mode, while the other fourteen inputs count at 1 kHz. Filtering can be set between 0 and 12 ms on standard inputs.
Of the ten transistor outputs, Q0 to Q3 are fast outputs that can generate PTO pulses at 100 kHz on four channels, PWM up to 20 kHz or pulse output at 100 kHz, while Q4 to Q9 switch at 1 kHz. Output current per point is 0.5 A (0.1 A for fast outputs in PTO mode), the outputs are protected against short circuit, and a fast output resets after 12 s.
Uses of the TM241C24T across Oman and the GCC
Typical roles are packaging lines, conveyors, pump skids, compressor packages and water treatment units where positioning or fast counting is needed but plant-network connection is handled elsewhere. Extreme heat in unconditioned panels is the main field issue, so a cabinet design that holds the ambient inside the datasheet limit is more important than the controller itself.
Certifications listed are cULus, CE, UKCA and RCM, plus marine approvals from DNV-GL, ABS and LR. Humidity is rated 10 to 95 % without condensation and the altitude limit is 2000 m.
Documents and quotation
The Schneider Electric datasheet for the this unit is attached on this page, so you can compare the listed values with your design before ordering. Check the inrush current and cable-length notes first.
To request a quotation for the TM241C24T, send the quantity, delivery destination and any project reference through the RFQ form. Seven Star LLC supplies Schneider Electric automation products in Oman and the GCC as an independent supplier based in Muscat, and we confirm stock status and lead time against your request.
Datasheets & Documents
- Datasheet Schneider Electric TM241C24T Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric TM241C24T Modicon M241 24 I/O
Answers from our engineering team on installation, compatibility and integration.
01What I/O does the TM241C24T have?
Fourteen 24 V DC inputs (8 of them fast) and ten transistor outputs at 24 V DC, 0.5 A, positive logic, of which four are fast outputs.
02Does the TM241C24T have Ethernet?
No. It provides serial 1 (RJ45, RS232/RS485), serial 2 (screw terminals, RS485) and a mini-B USB port. TM241CE24T and TM241CE24U add Ethernet.
03How fast can the TM241C24T count pulses?
Four fast inputs count up to 200 kHz in single-phase or pulse/direction mode and up to 100 kHz in A/B mode.
04How many TM3 modules can be added to the TM241C24T?
Up to 7 in the local architecture or 14 in the remote architecture.
05What is the size and weight of the TM241C24T?
150 mm wide, 90 mm high, 95 mm deep, net weight 0.53 kg.