Schneider Electric SR2D101BD Zelio 10 I/O 24 V DC Relay
Description
SR2D101BD: Zelio Logic smart relay with 10 I/O on 24 V DC
The SR2D101BD is a Schneider Electric Zelio Logic compact smart relay. It packs 6 discrete inputs and 4 relay outputs into a single housing and replaces a small amount of hard-wired relay logic with a programme held in memory. SR2D101BD is the display-less and clockless variant powered from 24 V DC, so the first thing to settle before ordering is that your control supply really matches that figure. Seven Star LLC supplies the SR2D101BD in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference against the datasheet values: the letter after SR2 (D) lines up with no display, no clock; the three digits give the I/O size (10 I/O here); and the suffix (BD) corresponds to the supply of 24 V DC. This reading is our interpretation of the datasheet data rather than a published ordering table, so confirm the exact reference on your drawing before you send an order.
Supply, programme capacity and environmental limits
Rated supply is 24 V DC with limits of 19.2–30 V. The datasheet gives a maximum supply current of 100 mA and a power figure of 3 W, both without extension, which is useful when several units share a small control transformer or a 24 V supply. Reverse polarity protection is fitted.
Operating temperature is −20 to 55 °C, with the lower band of −20 to 40 °C applying in a non-ventilated enclosure; storage is −40 to 70 °C and relative humidity up to 95 % without condensation. Protection is IP20 at the terminal block and IP40 at the front panel, pollution degree 2, overvoltage category III, at altitudes up to 2000 m. In Gulf installations that mostly means the relay belongs inside a closed, ventilated cabinet and not in an open junction box exposed to dust and heat.
The datasheet quotes a programme size of 240 with ladder programming, a cycle time of 6–90 ms, and a programme backup of 10 years at 25 °C. The memory is checked on each power-up. There is no real-time clock in this variant, so time-of-day schedules are not available; the programme is limited to logic, counters and relative timers. If your application needs a weekly timetable, move to a B or E type from the same family. There is no local display, so diagnostics rely on the programming tool and on the status of the wired devices.
Technical specifications of the SR2D101BD
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / SR2D101BD |
| Range of product | Zelio Logic |
| Product type | Compact smart relay |
| I/O configuration | 10 I/O: 6 discrete inputs, 4 relay outputs |
| Local display | No |
| Real-time clock | No |
| Programme size | 240 with ladder programming |
| Cycle time | 6–90 ms |
| Backup time | 10 years at 25 °C |
| Clock drift | 12 min/year at 0–55 °C; 6 s/month at 25 °C |
| Rated supply voltage | 24 V DC |
| Supply voltage limits | 19.2–30 V |
| Maximum supply current | 100 mA (without extension) |
| Power | 3 W without extension |
| Reverse polarity / terminal inversion protection | With |
| Discrete input voltage / current | 24 V DC / 4 mA |
| Analogue inputs | 0 |
| Outputs | 4 relay |
| Output voltage limits | 24–250 V AC (relay output); 5–30 V DC (relay output) |
| Output current | 8 A for all 4 outputs for relay output |
| Net weight | 0.22 kg |
| Protection degree | IP20 (terminal block) conforming to IEC 60529; IP40 (front panel) conforming to IEC 60529 |
| Operating temperature | -20 to 55 °C (-20 to 40 °C in a non-ventilated enclosure) |
| Storage temperature | -40 to 70 °C |
| Relative humidity | 95 % without condensation or dripping water |
| Operating altitude | 2000 m; 2 8 Nov 2026 |
How the SR2D101BD compares with related Zelio Logic references
The table lists the nearest relatives of the SR2D101BD in the same family, taken from their own datasheets. They share the housing style and the screw-terminal wiring but differ in supply, I/O count, display and clock.
| Reference | I/O | Supply | Display | Clock | Analogue inputs |
|---|---|---|---|---|---|
| SR2D201BD | 20 | 24 V DC | No | No | 2 |
| SR2A201BD | 20 | 24 V DC | Yes | No | 2 |
| SR2E121BD | 12 | 24 V DC | No | Yes | 4 |
| SR2E201BD | 20 | 24 V DC | No | Yes | 6 |
| SR2A101FU | 10 | 100-240 V AC | Yes | No | – |
Installation, wiring and maintenance of the SR2D101BD
The datasheet specifies screw terminals for 0.2 to 2.5 mm² solid or semi-solid conductors and 0.25 to 2.5 mm² flexible conductors with cable end, with a tightening torque of 0.5 N.m. Wire the supply and input groups in line with the terminal markings, and keep input cabling separate from output cabling that carries inductive loads. For inductive loads on relay outputs, suppression at the load is a standard practice that protects the contacts.
After wiring, power up with the loads disconnected, check each input state, then exercise each output before connecting field equipment. Keep a backup copy of the programme with the project documents so that a replacement unit can be programmed quickly. Site inspections should look at terminal tightness, cabinet temperature and dust build-up on ventilation openings.
Selection checklist for the SR2D101BD
- Confirm the control supply: 24 V DC (polarity matters).
- Count field inputs and outputs: this unit offers 6 inputs and 4 relay outputs; spare capacity should be considered before choosing 10 I/O.
- Check whether the load needs relay contacts.
- Decide on display (absent) and clock (absent) against the programme you intend to write.
- Check the panel space: the datasheet weight is 0.22 kg and the width and depth should be checked on the datasheet drawing.
Typical uses of the SR2D101BD in Oman and the GCC
With 10 I/O on 24 V DC, SR2D101BD fits small automation tasks where a full PLC would be excessive: lighting and signage sequences, simple conveyor and packing interlocks, and tank level and transfer control. In the Gulf these panels face high ambient temperatures and fine dust, so cabinet ventilation and the derating note in the datasheet deserve attention. Utilities, facilities contractors and OEM panel builders use units of this size mainly for standalone sequences, local backup logic and retrofits of ageing relay panels.
Inputs and outputs of the SR2D101BD
The inputs on this unit are 24 V class DC inputs of the resistive type rated 24 V DC at 4 mA, conforming to IEC 61131-2 type 1, with a counting frequency of 1 kHz. The datasheet states that three-wire PNP proximity sensors can be connected directly, which makes the unit a natural fit for sensor-driven sequences. State 1 is guaranteed from ≥ 15 V and state 0 up to ≤ 5 V. This variant has no analogue inputs, so it suits purely on/off signals; if you need to read a level or temperature value pick one of the DC members that list analogue inputs.
The 4 outputs are relay outputs with normally open contacts, switching 24–250 V AC or 5–30 V DC. The datasheet gives a thermal current of 8 A shared across the outputs, a minimum switching capacity of 10 mA at 12 V, and a mechanical durability of 10000000 cycles. Because the contacts are relay-type, one output can switch a mains-powered contactor coil while its neighbour switches a low-voltage signal.
Information to send with an RFQ for the SR2D101BD
- Exact reference SR2D101BD and the quantity required.
- Control supply voltage and frequency available on site.
- Type of loads on the outputs and whether surge suppression is fitted.
- Whether a programming cable or other accessory is needed in the same order.
- Delivery location and any project deadline.
Documents and quotation
The manufacturer datasheet for the SR2D101BD is attached on this page and lists the full specification summarised above. Check the datasheet revision date against your project requirements.
Send us the reference SR2D101BD, quantity and delivery location and Seven Star LLC will reply with a quotation request confirmation. We supply as an independent supplier based in Muscat.
Other Models in the Se Zelio Sr2 Range
Seven Star LLC supplies models from the Se Zelio Sr2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric SR2A101FU Zelio 10 I/O 100-240 V AC Relay | Logic Controllers | View details |
| Schneider Electric SR2B121FU Zelio 12 I/O 100-240 V AC Relay | Logic Controllers | View details |
| Schneider Electric SR2D101BD Zelio 10 I/O 24 V DC Relay | Logic Controllers | You are viewing this model |
| Schneider Electric SR2E121B Zelio 12 I/O 24 V AC Relay | Logic Controllers | View details |
Datasheets & Documents
- Datasheet Schneider Electric SR2D101BD Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric SR2D101BD Zelio 10 I/O 24 V DC
Answers from our engineering team on installation, compatibility and integration.
01What supply voltage does the SR2D101BD need?
The datasheet lists a rated supply of 24 V DC with limits of 19.2…30 V. Match it to the actual control supply before ordering.
02How many inputs and outputs does the SR2D101BD have?
It is a 10 I/O unit with 6 discrete inputs and 4 relay outputs. It has no analogue inputs.
03Does the SR2D101BD have a display and a clock?
Display: no. Real-time clock: no. These two points are what separate it from other references in the Zelio Logic range.
04What are the output ratings of the SR2D101BD?
Relay outputs with normally open contacts, 24...250 V AC (relay output) or 5...30 V DC (relay output), thermal current 8 A for all 4 outputs for relay output.
05What temperature range does the SR2D101BD allow?
Operation from -20 to 55 degC (-20 to 40 degC in a non-ventilated enclosure) and storage from -40 to 70 degC, with front protection IP40 and terminal block IP20.