- Automation & ControlView all 3,053 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric SRVS6KIL Easy UPS 6 kVA Tower
Description
SRVS6KIL: 6 kVA tower Easy UPS 1Ph On-Line
The SRVS6KIL is a Schneider Electric Easy UPS 1Ph On-Line unit rated 6000 VA / 6000 W with a sine-wave double-conversion output. It is built as a tower chassis and is the extended-runtime version of its family, meaning it relies on external battery packs rather than a large internal string. Seven Star LLC supplies the SRVS6KIL in Oman and the GCC as an independent supplier based in Muscat.
The datasheet carries a lifecycle notice: the reference is marked discontinued, with a stated discontinuation date of 31 Oct 2026 and end of service on 30 Aug 2029. Check current availability and ask about replacement options when you enquire. The reading of the reference below is our interpretation of the product title, not a published ordering table: SRVS6KIL is described as an extended runtime model, in tower form, and a hard-wired output.
Technical specifications of the SRVS6KIL
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / SRVS6KIL |
| Range | Easy UPS 1Ph On-Line |
| Topology / waveform | On-Line (double conversion), sine wave |
| Rated power | 6000 VA / 6000 W |
| Input voltage | 230 V AC single phase (220 V and 240 V also listed) |
| Input frequency | 40–70 Hz auto sensing |
| Input connection | 1 hard wire 3-wire (1P + N + E) |
| Output connection | Hard wire 3-wire (1P + N + E) for 1 zone(s) |
| Output voltage | 230 V AC single phase, configurable 220 / 230 / 240 V |
| Output frequency | 50/60 Hz ± 3 Hz sync to mains |
| Bypass | Internal bypass (automatic and manual) |
| Crest factor | 3:1 |
| Efficiency at full load | 94 % (full load) |
| Input window (half / full load) | 110–300 V half load / 176–300 V full load |
| Battery type | Lead-acid external included |
| Battery voltage | 240 V |
| Battery energy | 1512 VAh |
| Typical recharge time | 5h |
| Battery charging power | 1170 W rated |
| Battery life | 3–5 year(s) |
| Dimensions (H x W x D) | 368 × 380 × 485 mm |
| Product weight | 73 kg |
| Acoustic level | 55 dBA |
| Heat dissipation | 1172 Btu/h |
| Protection | IP20 |
| Operating temperature | 0–40 °C |
| Relative humidity | 0–95 % non-condensing |
| Operating altitude | 0–3000 m |
| Certification / standards | CE, UKCA; EN/IEC 62040-1 and 62040-2 |
| Warranty | 24 months |
Installation, commissioning and maintenance of the SRVS6KIL
Before first start, check that the input supply, frequency and earthing agree with the datasheet, and set the nominal output voltage to match the equipment. Operate within 0–40 °C ambient, relative humidity up to 95 % without condensation and altitudes up to 3000 m; the enclosure is IP20, so the room must be clean and indoor. The upstream breaker and cable section must be sized by the installer for the full input current of a 6 kVA unit.
After commissioning, test the transfer to battery with a real load, record the runtime, and log it for later comparison. Keep the intelligent-card slot and the USB or serial port in mind if you want remote alarms. Maintenance should cover battery condition, fan and vent cleanliness, firmware or card settings and a periodic check of the bypass operation.
Battery system and runtime of the SRVS6KIL
SRVS6KIL is the extended-runtime variant: the datasheet shows a 240 V battery system, a rated battery charging power of 1170 W rated and a typical recharge time of 5h. The higher charger rating is the practical difference from the standard version, because it can recover a larger external battery string in reasonable time. Battery energy is listed as 1512 VAh and the runtime is extendable by adding battery packs of the matching voltage.
Lead-acid batteries have a datasheet service life of 3–5 year(s) years, and ambient temperature is the main factor that shortens it. In Gulf plant rooms the cooling of the battery space deserves as much attention as the cooling of the UPS. Schedule battery tests and replacement against the figure above and against actual room temperature, not against the date of installation alone.
Selection checklist for the SRVS6KIL
- Load: connected load must stay within 6000 W as well as 6000 VA; the watt figure is the limiting one when the load has a power factor below the rating.
- Connections: a hard-wired feeder and output circuit are required.
- Form: floor standing with space and a level surface.
- Runtime: extended-runtime model; select battery packs of the matching voltage (240 V).
- Lifecycle: the datasheet shows the reference as discontinued, so confirm stock and a replacement before committing a project.
Size, weight and mounting of the SRVS6KIL
The chassis measures 368 × 380 × 485 mm (H × W × D) and weighs 73 kg. It stands vertically as a tower, with the datasheet listing it as not rack-mountable. The floor area needed is small, but the weight is significant and the floor should be level and able to carry it. Leave clear space at the front and rear for airflow.
Acoustic level is 55 dBA and heat dissipation is 1172 Btu/h. Include the dissipated heat in any room cooling calculation.
Typical uses of the SRVS6KIL in Oman and the GCC
A 6 kVA on-line unit like this unit suits control-room workstations and servers, telecom and network rooms and building-management and access-control systems, where mains dips and short outages cause more damage than a long blackout would. Gulf sites also deal with high ambient temperatures, dust and unstable feeders from generators or weak grids, so the clean sine output and the input window are valuable, but room cooling and a dust-free enclosure matter just as much as the unit rating. Where the load must run longer than a standard battery allows, the external battery option is the usual route.
Power path and output behaviour
In on-line operation the load is always fed from the inverter, so the output is isolated from mains disturbances and the datasheet lists a sine waveform at 50/60 Hz ± 3 Hz synchronised to mains. The input accepts 230 V AC single phase with 220 V and 240 V also listed, and an auto-sensing frequency range of 40–70 Hz; the output is configurable for 220, 230 or 240 V nominal. Crest factor is 3:1 and an internal bypass is provided with both automatic and manual operation. This unit lists an efficiency of 94 % (full load) at full load.
The input window is stated as 110–300 V half load and 176–300 V full load, which describes the mains range over which the unit can carry load without going to battery. In practice that is a useful margin on weak or fluctuating supplies, but the figures belong to the datasheet and the unit’s own protection limits apply.
Information to send with an RFQ for the SRVS6KIL
- Exact reference SRVS6KIL and the quantity needed.
- Connected load in W and VA, and the required runtime.
- Available supply voltage and frequency, and the earthing arrangement.
- Whether matching battery packs, rail kits or a network card are needed in the same order.
- Delivery location and project timeline, plus any replacement requirement given the lifecycle notice.
Documents and quotation
The manufacturer datasheet for the SRVS6KIL is attached on this page. It carries the full specification summarised above and the lifecycle notice; check its revision date against your project.
Send us the reference SRVS6KIL, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat.
See also: Schneider Electric SRVS2KRILRK Easy UPS 2 kVA Rack; Schneider Electric SRVS3KIL Easy UPS 3 kVA Tower.
Other Models in the Se Easy Ups Srvs Range
Seven Star LLC supplies models from the Se Easy Ups Srvs range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
Datasheets & Documents
- Datasheet Schneider Electric SRVS6KIL Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric SRVS6KIL Easy UPS 6 kVA Tower
Answers from our engineering team on installation, compatibility and integration.
01What is the rating of the SRVS6KIL?
The datasheet lists 6000 VA / 6000 W, on-line double-conversion with a sine-wave output at 230 V single phase, configurable for 220 or 240 V.
02Is the SRVS6KIL still in production?
The datasheet shows the reference as discontinued, with discontinuation dated 31 Oct 2026 and end of service on 30 Aug 2029. Confirm availability before ordering.
03How does the SRVS6KIL connect to mains and load?
Input and output are hard wire 3-wire (1P + N + E) terminations, so a qualified installer must wire it.
04What battery does the SRVS6KIL use?
A 240 V lead-acid system with a typical recharge time of 5h. It is the extended-runtime version and the runtime can be extended with matching battery packs.
05What are the dimensions and weight of the SRVS6KIL?
368 mm high, 380 mm wide and 485 mm deep, weighing 73 kg. It is a tower unit.


















Reviews
There are no reviews yet.