EnerSys PowerSafe OPzV 2V Gel Battery 215-3170Ah
Overview of the EnerSys PowerSafe OPzV Gel Battery Range
EnerSys PowerSafe OPzV cells are 2 V valve-regulated lead-acid batteries that pair tubular positive plates with an immobilised gel electrolyte, a construction that has been the industry reference for stationary standby power for decades. The EnerSys range summary lists capacities from 215 Ah to 3170 Ah at the 10 hour rate, with values that exceed the figures required by DIN standards, and a 20 year design life at 20 degrees Celsius. The cells follow the classic DIN single-cell format, which means they can be arranged in long series strings for 24 V, 48 V, 110 V, 220 V or higher DC systems.
Seven Star LLC supplies the EnerSys PowerSafe OPzV on request from Muscat, targeting utilities, industrial plants and telecom operators in Oman and the GCC. Gel OPzV cells are a common choice for substation DC supplies, protection and switchgear tripping batteries, signalling systems and power station auxiliaries, where long service life and low maintenance justify the choice over a cheaper short-life battery.
Gel and Tubular Technology in the EnerSys PowerSafe OPzV
Inside every EnerSys PowerSafe OPzV cell the positive electrode is a tubular plate made with a lead-tin-calcium alloy, while the negative electrode is a flat plate with a lead-calcium alloy grid. A low-resistance microporous separator keeps the plates apart, and the sulphuric acid is immobilised as a gel. Because the electrolyte cannot stratify or spill, cells can be installed vertically or horizontally, and the very low water loss means no topping up is needed during normal service.
The tubular positive plate gives the battery its tolerance of deep discharge. The summary states that the range is proof against deep discharge in line with DIN 43539 part 5 and shows excellent recovery after deep discharge, together with a high cycle life in addition to float life. That combination suits sites where the battery occasionally carries the full load for hours, for example during a prolonged outage at a remote pumping station.
Construction and Installation of the EnerSys PowerSafe OPzV
Containers and lids are made of ABS with high resistance to shock and vibration, and a UL94 V-0 flame retardant ABS version is available as an option. Terminals are M10 with a brass insert and use a pillar seal designed to prevent electrolyte leakage. A one-way pressure relief valve with an integral flame arrestor adds operational safety, and fully insulated solid copper inter-cell connectors allow voltage measurements along the string, with flexible connectors also available.
The recommended float charge voltage is 2.25 volts per cell at 20 degrees Celsius and the permissible operating temperature range is minus 10 to plus 45 degrees Celsius. Storage life is 12 months at 20 degrees Celsius or 6 months at 30 degrees Celsius, so stock should be commissioned promptly in hot warehouses. Optional racking simplifies installation and saves space, and horizontal installation can reduce floor space use.
Commissioning and Service Planning for the EnerSys PowerSafe OPzV
Good results from the EnerSys PowerSafe OPzV depend on correct charger settings and installation practice as much as on the cells. The charger float voltage should follow the EnerSys recommendation for the ambient temperature of the battery room, and a string should be built from cells of the same type and production period. Batteries must be installed in accordance with IEC 62485-2 and national regulations, with adequate ventilation, even though valve-regulated cells emit far less gas than flooded designs.
During service, engineers normally record string voltage, individual cell voltages through the insulated connectors, room temperature and charger output, and compare them with the commissioning values. A planned capacity test at intervals chosen by the asset owner shows the remaining margin against the autonomy required by the protection and control system. Seven Star LLC can help prepare an ordering specification that lists the cell type, the number of cells, the connector kit and the racking, so that the delivery arrives complete and ready for installation.
Key Features of the EnerSys PowerSafe OPzV
- Proven tubular gel VRLA technology with an extensive capacity range of 215 Ah to 3170 Ah.
- C10 capacities that exceed DIN standard values.
- 20 year design life at 20 degrees Celsius with very low maintenance and no water addition.
- Excellent deep discharge recovery and good cyclability.
- Classic industry-standard DIN design with 2 V single cells.
- Fully insulated connectors, immobilised electrolyte and a one-way valve with flame arrestor for operational safety.
- Flexible vertical or horizontal installation.
- Tested to IEC 60896-21 and compliant with defined requirements of IEC 60896-22, conforming to DIN 40742.
Applications for the EnerSys PowerSafe OPzV in Oman and the GCC
The EnerSys PowerSafe OPzV range is well matched to the Sultanate of Oman’s transmission and distribution network, where 110 V and 220 V DC systems energise circuit breaker trip coils, protection relays and SCADA equipment in grid stations. It is equally applicable to power generating stations, railway and airport signalling, seaport systems at Sohar and Duqm, emergency lighting, measurement and automation systems, and telecom exchanges, all of which are named in the manufacturer summary as typical applications.
Seven Star LLC can help size a string from the load profile, the required autonomy and the end-of-discharge voltage of the charger and DC bus. We also supply the EnerSys PowerSafe DU battery for flooded cell designs, the Vertiv Liebert EXL UPS for large critical loads, and the APC SY128K160H Symmetra PX UPS, so that battery and UPS can be quoted together.
Technical Specifications of the EnerSys PowerSafe OPzV
Values below come from the EnerSys EMEA range summary and apply to a fully charged cell at 20 degrees Celsius. Height is overall height including connectors and shrouds.
| Parameter | Specification |
|---|---|
| Model | 4 OPzV 200, 5 OPzV 250, 6 OPzV 300, 5 OPzV 350, 6 OPzV 420, 7 OPzV 490, 6 OPzV 600, 8 OPzV 800, 10 OPzV 1000, 12 OPzV 1200, 12 OPzV 1500, 16 OPzV 2000, 20 OPzV 2500, 24 OPzV 3000 |
| Nominal voltage | 2 V per cell |
| Capacity at 10 hour rate to 1.80 V per cell | 215, 265, 320, 385, 465, 540, 705, 940, 1170, 1410, 1600, 2110, 2640 and 3170 Ah respectively |
| Terminal pairs | 1 pair up to 6 OPzV 600; 2 pairs for 8 to 12 OPzV types; 3 pairs for 16 OPzV 2000; 4 pairs for 20 and 24 OPzV types |
| Length x width x height (mm), examples | 103 x 206 x 403 (4 OPzV 200); 145 x 206 x 695 (6 OPzV 600); 210 x 275 x 845 (12 OPzV 1500); 212 x 576 x 820 (24 OPzV 3000) |
| Weight, examples | 19.5 kg (4 OPzV 200); 50.0 kg (6 OPzV 600); 120.0 kg (12 OPzV 1500); 240 kg (24 OPzV 3000) |
| Short circuit current, examples | 2195 A (4 OPzV 200); 3796 A (6 OPzV 600); 14964 A (24 OPzV 3000) |
| Float charge voltage | 2.25 V per cell at 20 degrees Celsius |
| Operating temperature | Minus 10 to plus 45 degrees Celsius |
| Design life | 20 years at 20 degrees Celsius |
| Standards | IEC 60896-21 and 22, DIN 40742, DIN 43539 part 5, Eurobat Very Long Life, IEC 62485-2 for installation |
Request a Quote for the EnerSys PowerSafe OPzV
To request the EnerSys PowerSafe OPzV, provide the DC system voltage, the required capacity and discharge duration, the ambient temperature and whether racking is needed. Seven Star LLC will propose the cell type and string layout, confirm lead times and prepare a formal quotation for delivery to Oman and the GCC. The EnerSys range summary is attached to this page, and our engineers are available to review the datasheet details with your project team.
- Datasheet EnerSys PowerSafe OPzV Battery Range Summary Download
EnerSys PowerSafe ranges listed
Three PowerSafe ranges appear here. PowerSafe OPzV cells are 2 V gel batteries, listed from 215 to 3170 Ah. PowerSafe SBS EON is a VRLA range using thin plate pure lead technology, listed from 62 to 3900 Ah. PowerSafe DU is the third range on the page. Across the PowerSafe brand the manufacturer offers AGM, gel, flooded and thin plate pure lead designs, in front-terminal, top-terminal and DIN sizes.Ordering EnerSys batteries: what we need
A battery inquiry needs more than a brand name. Send the cell or monobloc type printed on the label, the nominal voltage and capacity, and the number of cells in the string. Add the system voltage, the required backup time and load if the string is being resized, the terminal layout, and the rack or cabinet dimensions. A photo of the label and of the existing layout removes most doubt.Browse EnerSys products by category: UPS and Batteries.