Schneider Electric SR3PACKBD Zelio Discovery Pack 10 I/O

Description

SR3PACKBD: Zelio Logic discovery pack with 10 I/O on 24 V DC

The SR3PACKBD is a Schneider Electric Zelio Logic discovery pack: a boxed starter kit rather than a bare controller. According to the datasheet the kit composition is the smart relay SR3B101BD together with the PC connection cable SR2USB01. SR3PACKBD therefore gives a commissioning engineer everything needed to download and test a first programme on the bench: a unit with 6 discrete inputs and 4 relay outputs (that is 10 I/O), a local display, and the USB lead. Seven Star LLC supplies the SR3PACKBD in Oman and the GCC as an independent supplier based in Muscat.

The reference itself reads as a pack code: the PACK portion identifies the kit, and the trailing letters follow the supply convention of the bundled controller (BD for the 24 V DC version). This is our reading of the datasheet data, not a published ordering table, so confirm the exact reference on your own order drawing.

How the SR3PACKBD compares with its Zelio Logic neighbours

The rows below are the nearest relatives of the SR3PACKBD among the references we handle, each taken from its own datasheet. They share the screw-terminal housing style and the same relay-output ratings, but differ in supply, I/O count and in whether you buy a pack or a unit.

Reference Form I/O Supply Inputs / outputs
SR3B101BD Modular relay 10 24 V DC 6 / 4
SR2PACK2BD Pack 20 24 V DC 12 / 8
SR3B101FU Modular relay 10 100–240 V AC 6 / 4
SR2PACKFU Pack 12 100–240 V AC 8 / 4
SR3B261FU Modular relay 26 100–240 V AC 16 / 10

Technical specifications of the SR3PACKBD

Parameter Specification
Manufacturer / part number Schneider Electric / SR3PACKBD
Range Zelio Logic
Product type Modular discovery pack
Kit composition SR3B101BD smart relay and SR2USB01 PC cable
Inputs / outputs 10 I/O: 6 discrete inputs, 4 relay outputs
Analogue inputs 4
Local display Yes
Real-time clock Yes
Programme size 120 lines (ladder); 0–200 lines (FBD)
Cycle time 6–90 ms
Programme backup 10 years at 25 °C
Rated supply 24 V DC (19.2–30 V)
Supply current 100 mA with or without extensions
Power 3 W without extension, 8 W with extensions
Relay output rating 24–250 V AC / 5–30 V DC, normally open
Output thermal current 8 A for all 4 outputs
Net weight 0.7 kg
Protection IP20 terminal block, IP40 front panel
Operating temperature −20 to 55 °C (−20 to 40 °C in a non-ventilated enclosure)
Storage temperature −40 to 70 °C
Relative humidity 95 % without condensation or dripping water
Operating altitude 2000 m
Warranty 18 months
Certifications listed GL, UL, CSA, GOST, C-Tick

Installation, wiring and maintenance of the SR3PACKBD

Terminals accept 0.2–2.5 mm² solid or semi-solid conductors and 0.25–2.5 mm² flexible conductors with cable end, tightened to 0.5 N.m. The unit mounts on a 35 mm DIN rail, or can be screw-fixed with its retractable lugs, per the datasheet drawings. The datasheet connection diagrams call for a 1 A quick-blow fuse or circuit-breaker in the supply and inductive-load suppression where relay outputs drive coils.

Power up with field loads disconnected, check each input state on the display, then force each output before connecting equipment. Keep a copy of the programme with the project records so that a replacement can be loaded quickly; as a spare, the SR3PACKBD should be stored dry within the −40 to 70 °C storage range. Periodic inspection should cover terminal tightness, cabinet temperature and dust on ventilation openings.

Supply, programme and environmental limits

The rated supply is 24 V DC with limits of 19.2–30 V. Quoted consumption is 100 mA with or without extensions, and the power figure is 3 W without extension, 8 W with extensions. Reverse polarity protection is listed, which forgives a swapped supply pair during commissioning. The programme memory is checked on every power-up and is backed up for 10 years at 25 °C, with a cycle time of 6–90 ms. The unit has a real-time clock, so weekly schedules and timed events can live inside the programme; the datasheet gives a clock drift of 12 min/year over 0–55 °C or 6 s/month at 25 °C.

Operating temperature is −20 to 55 °C, limited to −20 to 40 °C in a non-ventilated enclosure; storage is −40 to 70 °C; humidity is up to 95 % without condensation. Protection is IP20 at the terminals and IP40 at the front, pollution degree 2, overvoltage category III, up to 2000 m. In Gulf plants that translates to a closed, ventilated cabinet, not an open junction box exposed to heat and dust.

Inputs and outputs of the SR3PACKBD

The 6 discrete inputs of the SR3PACKBD are resistive 24 V DC inputs conforming to IEC 61131-2 type 1, drawing 4 mA each with a counting frequency of 1 kHz. State 1 is guaranteed from 15 V and state 0 up to 5 V, and the datasheet lists three-wire PNP proximity sensors as compatible, so limit switches and sensors can be wired straight to the terminals. Part of this input group is dual-purpose: 4 inputs can work as analogue inputs for 0–10 V or 0–24 V signals with 8-bit resolution (39 mV per step), a stated conversion error of ±5 % at 25 °C rising to ±6.2 % at 55 °C, and screened cable up to 10 m. Temperature probes of the NTC 10k type, the KTY81 family and Pt 500 are listed, so a simple thermostat function needs no extra transmitter.

The 4 outputs are relay outputs with normally open contacts, suitable for 24–250 V AC or 5–30 V DC. Thermal current is 8 A for all 4 outputs. The datasheet quotes an electrical life of 500,000 cycles in AC-12 at 230 V / 1.5 A, AC-15 at 230 V / 0.9 A, DC-12 at 24 V / 1.5 A and DC-13 at 24 V / 0.6 A, a minimum switching capacity of 10 mA at 12 V, a mechanical life of 10 million cycles, and a response time of 10 ms on and 5 ms off. Operating rate is 10 Hz without load but only 0.1 Hz at rated current, so these relays suit contactor coils and signalling duties rather than rapid cycling.

Choosing the SR3PACKBD as a starter or spare kit

  • Confirm the control supply: 24 V DC. A pack with the other supply is a different reference.
  • Count the field signals: 6 inputs and 4 relay outputs must cover your sequence, with spare capacity if the process may grow.
  • Decide whether you need the PC cable: it is included here, so there is no need to order SR2USB01 separately for the first download.
  • Check the clock requirement against the note in the specifications table.
  • Check panel space against the dimensional drawing in the datasheet; the packed kit weighs 0.7 kg.

Typical uses of the SR3PACKBD in Oman and the GCC

With 10 I/O on 24 V DC, this unit fits small automation tasks where a PLC would be excessive: simple conveyor and packing interlocks, ventilation and air-handling fans in buildings and tank level and transfer control. As a kit it also suits training rooms, panel-shop bench tests and quick proof-of-concept builds. Ambient temperatures are high across the region and dust is fine, so cabinet ventilation and the derating note above deserve attention. Utilities, facilities contractors and OEM panel builders use units of this size mainly for standalone sequences, local backup logic and retrofits of ageing relay panels.

Information to send with an RFQ for the SR3PACKBD

  • Exact reference SR3PACKBD and quantity.
  • Control supply voltage and frequency on site.
  • Load types on the outputs and whether surge suppression is fitted.
  • Any accessories required in the same order, such as extension modules or a programming cable.
  • Delivery location and project deadline.

Documents and quotation

The manufacturer datasheet for the SR3PACKBD is attached on this page and lists the full specification summarised above, including dimension drawings and connection diagrams. Check the revision date against your project requirements.

Send us the reference SR3PACKBD, the quantity and the delivery location and Seven Star LLC will reply to your RFQ. We supply as an independent supplier based in Muscat.

Other Models in the Se Zelio Sr Range

Seven Star LLC supplies models from the Se Zelio Sr range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric SR2PACK2BD Zelio Discovery Pack 20 I/OLogic ControllersView details
Schneider Electric SR3B101BD Zelio Modular Smart Relay 10 I/OLogic ControllersView details
Schneider Electric SR3PACKBD Zelio Discovery Pack 10 I/OLogic ControllersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric SR3PACKBD Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric SR3PACKBD Zelio Discovery Pack

Answers from our engineering team on installation, compatibility and integration.

01What supply does the SR3PACKBD need?
The datasheet lists a rated supply of 24 V DC with limits of 19.2-30 V. Match it to your control supply before ordering, because the other supply is a different reference.
02How many inputs and outputs does the SR3PACKBD have?
It offers 10 I/O: 6 discrete inputs and 4 relay outputs with normally open contacts. 4 of the inputs can also be used as analogue inputs.
03What are the output ratings of the SR3PACKBD?
Relay outputs for 24-250 V AC or 5-30 V DC, thermal current 8 A for all 4 outputs. Electrical life is 500,000 cycles at 230 V / 1.5 A in AC-12.
04What is included with the SR3PACKBD?
The datasheet kit composition is the smart relay SR3B101BD plus the PC connection cable SR2USB01.
05What temperature range does the SR3PACKBD allow?
Operation from -20 to 55 degC (-20 to 40 degC in a non-ventilated enclosure) and storage from -40 to 70 degC, with front protection IP40 and terminals IP20.