Schneider Electric R9F12125 Resi9 1P 25 A C-curve MCB
Description
R9F12125: Resi9 1P 25 A C-curve miniature circuit breaker
The R9F12125 is a Schneider Electric Resi9 miniature circuit breaker (single-pole, 25 A, C curve) with thermal-magnetic tripping and a 6000 A breaking capacity at 230 V AC. It clips onto a DIN rail, carries ON/OFF indication on the toggle and is finished in white (RAL 9003), the colour that distinguishes the Resi9 range from the grey Easy9 range. Seven Star LLC supplies the R9F12125 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: across the references in this lane the digit after R9F12 follows the pole count and the last two digits follow the rated current, so R9F12125 reads as 1P and 25 A. This is our reading of the pattern and the product title, not a published ordering table, so always confirm the full reference. With one protected pole it breaks the phase conductor only and is intended for a single-phase branch where the neutral runs separately. The datasheet quotes 230 V AC as the operating voltage.
Technical specifications of the R9F12125
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / R9F12125 |
| Range / product name | Resi9 / Resi9 MCB |
| Product type | Miniature circuit-breaker |
| Device application | Protection |
| Poles / protected poles | 1P / 1 |
| Rated current [In] | 25 A |
| Network type / frequency | AC / 50/60 Hz |
| Trip unit | Thermal-magnetic |
| Curve code | C |
| Magnetic tripping limit | 5–10 × In (calculated 125–250 A) |
| Rated operational voltage [Ue] | 230 V AC |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz |
| Limitation class | 3 |
| Rated insulation voltage [Ui] | 440 V AC |
| Rated impulse withstand [Uimp] | 4 kV |
| Overvoltage category | III |
| Control / signalling | Toggle; ON/OFF indication |
| Mounting | Clip-on, DIN rail |
| Width | 18 mm (2 × 9 mm pitches) |
| Height / depth / embedding depth | 81 mm / 72 mm / 44 mm |
| Net weight | 120 g |
| Colour | White (RAL 9003) |
| Terminals | 1–25 mm² – rigid; 1–16 mm² – flexible with ferrule; 1–16 mm² – flexible |
| Wire stripping length | 14 mm |
| Tightening torque | 2 N.m |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Standard | EN/IEC 60898-1 |
| Quality label | EAC |
| Degree of protection | IP20 |
| Pollution degree / tropicalisation | 2 / 2 (IEC 60068-1) |
| Ambient temperature | Operation -25 to 60 °C; storage -40 to 60 °C |
| Relative humidity | 95 % at 55 °C |
| Packing | 1 piece, 95 g; carton of 12 |
| Warranty | 18 months |
Durability and environment for the R9F12125
The Resi9 datasheet lists 20000 cycles mechanical and 10000 cycles electrical operating cycles, which are higher than the 10000 and 4000 cycles that the Easy9 datasheets in the same lane quote. For a board that is switched often, for example circuits that are isolated at every maintenance visit, that margin is worth noting. Protection is IP20, pollution degree 2 and tropicalisation level 2.
Operating ambient is -25 to 60 °C and storage -40 to 60 °C, with humidity up to 95 % at 55 °C. In a Gulf building, enclosure temperature can be much higher than room temperature, and a breaker carrying its full rating in a closed board will run hotter than one lightly loaded, so allow for derating margin and ventilation. This unit itself is not a weatherproof device; the enclosure must keep dust and water away.
Fault level, insulation and limitation class of the R9F12125
The listed breaking capacity is 6000 A Icn at 230 V AC 50/60 Hz, with a rated operational voltage of 230 V AC. The insulation voltage Ui is 440 V AC and the impulse withstand Uimp is 4 kV, with overvoltage category III. The limitation class is 3, the highest class defined in the product standard, which means the breaker restricts the let-through energy of a fault more strongly than a class 1 or 2 device.
The datasheet does not publish a separate service breaking capacity line for this reference, so the 6000 A figure is the number to compare with the prospective short-circuit current at the board. In small residential and commercial supplies this is normally comfortable, but a board close to a large transformer or a long way upstream of a smaller one can see very different values, and the calculation belongs to the installer. Confirm that the network type and voltage on site match the 230 V AC line before ordering.
Installation and upkeep of the R9F12125
De-energise and prove dead, then clip the R9F12125 onto the rail and check that the toggle moves freely. Insert stripped conductors fully, tighten to 2 N.m with a calibrated driver, and fit ferrules where the datasheet lists flexible cable with ferrule. After switching on, confirm that the ON/OFF indication matches the toggle position and label the circuit.
Re-torque terminals during scheduled inspections, especially in boards that are warm or that carry vibration, and look for discoloured plastic that signals heat at a termination. If a breaker trips on a short circuit, find the cause before resetting; if it trips repeatedly on a normal load, the rating or the load is wrong rather than the device.
Trip behaviour of the R9F12125 at 25 A
The datasheet gives a magnetic tripping limit of 5 to 10 times In. At 25 A that corresponds to roughly 125 A to 250 A, the window in which the instantaneous element is expected to act on a short circuit. Smaller overloads are left to the thermal element, which takes longer to react the closer the current is to the rating. The C characteristic is the usual compromise for residential and light commercial wiring: it allows the short inrush of lamp drivers, small transformers and motors, yet it still reacts faster than a D curve to a real fault.
This unit is best matched to air-conditioner supplies, water heaters and larger socket groups. The conductor must be chosen first from the load, installation method and ambient temperature; the breaker is then picked to protect that conductor, not the other way round. The full time-current curve is part of the manufacturer’s published characteristics and is not reproduced here.
Selection checklist for the R9F12125
- Conductor: size the cable for the load and the installation method, then check that 25 A protects it.
- Poles: 1P suits a phase-only single-phase branch.
- Voltage: the datasheet lists 230 V AC; make sure it fits the supply.
- Fault level: compare 6000 A Icn at 230 V AC 50/60 Hz with the prospective short-circuit current.
- Load: C curve for moderate inrush; very high inrush needs a different characteristic.
- Space: 2 modules, 18 mm of rail.
Information to send with an RFQ for the R9F12125
- Exact reference R9F12125 and the quantity needed.
- Supply voltage, system type and earthing arrangement.
- Prospective short-circuit current at the board, if known.
- Load description and cable size for the circuit.
- Other poles or ratings needed in the same order.
- Delivery location and timeline.
Documents and quotation
The manufacturer datasheet for the R9F12125 is attached on this page and holds the full specification summarised above.
Send us the reference R9F12125, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat.
Other Models in the Se Resi9 Mcb C Range
Seven Star LLC supplies models from the Se Resi9 Mcb C range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric R9F12106 Resi9 1P 6 A C-curve MCB | Circuit Breakers | View details |
| Schneider Electric R9F12110 Resi9 1P 10 A C-curve MCB | Circuit Breakers | View details |
| Schneider Electric R9F12116 Resi9 1P 16 A C-curve MCB | Circuit Breakers | View details |
| Schneider Electric R9F12120 Resi9 1P 20 A C-curve MCB | Circuit Breakers | View details |
| Schneider Electric R9F12125 Resi9 1P 25 A C-curve MCB | Circuit Breakers | You are viewing this model |
| Schneider Electric R9F12132 Resi9 1P 32 A C-curve MCB | Circuit Breakers | View details |
| Schneider Electric R9F12140 Resi9 1P 40 A C-curve MCB | Circuit Breakers | View details |
| Schneider Electric R9F12206 Resi9 2P 6 A C-curve MCB | Circuit Breakers | View details |
Datasheets & Documents
- Datasheet Schneider Electric R9F12125 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric R9F12125 Resi9 1P 25 A C-curve
Answers from our engineering team on installation, compatibility and integration.
01What is the rating of the R9F12125?
The datasheet lists 25 A rated current, 1P, C curve, thermal-magnetic trip unit, with 6000 A Icn at 230 V AC 50/60 Hz.
02What is the magnetic trip range of the R9F12125?
The magnetic tripping limit is 5 to 10 times In, about 125 to 250 A for a 25 A device. This is calculated from the datasheet value.
03What size is the R9F12125 and how is it mounted?
It is 18 mm wide, 81 mm high and 72 mm deep (2 modules of 9 mm) and clips onto a DIN rail.
04What conductors fit the R9F12125 terminals?
Tunnel type terminals, top or bottom: 1-25 mm2 - rigid; 1-16 mm2 - flexible with ferrule; 1-16 mm2 - flexible. Strip 14 mm and tighten to 2 N.m.
05What durability and standard are listed for the R9F12125?
The datasheet lists 20000 cycles mechanical and 10000 cycles electrical cycles, standard EN/IEC 60898-1, limitation class 3, IP20 and an 18-month warranty.