Schneider Electric LV525425 CVS250NA 250 A Switch Disconnector

Description

LV525425: CVS250NA 250 A 3P switch-disconnector from EasyPact CVS

The LV525425 is a Schneider Electric EasyPact CVS switch disconnector, listed in the datasheet as the CVS250NA: three poles, a conventional thermal current of 250 A and a toggle handle on a fixed backplate base. It is built on the same moulded-case housing as the EasyPact CVS circuit breakers, but it has no trip unit. Its job is to make, carry and break load current and to provide isolation, not to clear faults. Seven Star LLC supplies the LV525425 in Oman and the GCC as an independent supplier based in Muscat.

The short name CVS250NA ends in NA, which the datasheet repeats as its breaking capacity code. On this family the letter pair marks a switch-disconnector version of the frame, so it shares the outer dimensions of a CVS250 breaker ( 105 x 86 x 161 mm). The datasheet states earth-leakage protection as without and the visible break as no.

Technical specifications of the LV525425

Parameter Specification
Manufacturer / part number Schneider Electric / LV525425
Range of product EasyPact CVS
Device short name CVS250NA
Product or component type Switch disconnector
Poles 3P
Network / frequency AC / 50/60 Hz
[Ie] rated operational current AC-22A: 250 A AC 50/60 Hz 220/240 V / AC-22A: 250 A AC 50/60 Hz 380/415 V / AC-22A: 250 A AC 50/60 Hz 440 V / AC-23A: 250 A AC 50/60 Hz 220/240 V / AC-23A: 250 A AC 50/60 Hz 380/415 V / AC-23A: 250 A AC 50/60 Hz 440 V
[Ith] conventional free air thermal current 250 A at 50 °C
[Icm] rated short-circuit making capacity 75 kA with upstream protection circuit breaker / 4.9 kA switch-disconnector alone
Breaking capacity code NA
Suitability for isolation Yes conforming to EN 60947-3 / Yes conforming to IEC 60947-3
Utilisation category AC-22A / AC-23A
[Icw] rated short-time withstand current 1.35 kA during 20 s conforming to IEC 60947-3 / 3.5 kA during 1 s conforming to IEC 60947-3 / 3.5 kA during 3 s conforming to IEC 60947-3
Earth-leakage protection Without
Visible break No
Contact position indicator Yes
Control / mounting Toggle, fixed, backplate
Upstream / downstream connection Front / Front
Mechanical durability 20000 cycles conforming to IEC 60947-3
Electrical durability AC-22A: 6500 cycles 415 V AC 50/60 Hz In conforming to IEC 60947-3 / AC-23A: 6500 cycles 415 V AC 50/60 Hz In conforming to IEC 60947-3
Connection pitch 35 mm
Width x depth x height 105 x 86 x 161 mm
Net weight 2.4 kg
Standards IEC 60947-3 / EN 60947-3
Product certifications GOST / IEC
Pollution degree 3 conforming to IEC 60664-1
Operating ambient temperature -25…70 °C
Storage ambient temperature -50…85 °C

Isolation and standards of the LV525425

The datasheet confirms suitability for isolation (Yes conforming to EN 60947-3; Yes conforming to IEC 60947-3). The contact position indicator is listed, but there is no visible break, so lock-off and voltage testing remain part of the safe-isolation procedure. Standards listed are IEC 60947-3 / EN 60947-3, with product certifications listed as GOST / IEC, pollution degree 3 conforming to IEC 60664-1 and electrical shock protection class Class II. Operating ambient range is -25…70 °C and storage range -50…85 °C.

Typical uses of the CVS250NA in Oman and the GCC

Switch-disconnectors in this size are used as local isolators for motor control centres, pump and fan feeders, workshop supplies and as section isolators in sub-distribution boards. In Oman and the GCC the main environmental concerns are heat in unventilated switchrooms and fine dust: the datasheet allows operation from -25…70 °C, and the enclosure, not the device, supplies the dust protection.

Short-circuit data of the LV525425: why upstream protection matters

This is the most important point on the datasheet. The rated short-circuit making capacity Icm is 75 kA only when an upstream protection circuit breaker is present; the device on its own is rated 4.9 kA. The short-time withstand current Icw is 1.35 kA during 20 s conforming to IEC 60947-3, 3.5 kA during 1 s conforming to IEC 60947-3 and 3.5 kA during 3 s conforming to IEC 60947-3. Those numbers are small against the fault level of a typical 415 V board, so it must always sit behind a breaker or fuse sized for the fault level and the cable, never as the only protection of a circuit.

In practice the upstream device is chosen first, and the CVS250NA is then selected to carry the same current. If the upstream device is a CVS breaker of the same frame, the pair share cut-out dimensions and connection pitch (35 mm), which keeps busbar and cable arrangements simple.

LV525425 and the other CVS switch-disconnectors

Three switch-disconnector references appear in this group: 160 A, 250 A and 400 A. They differ in more than current, as the table shows; the 400 A version also uses the larger housing with a 45 mm connection pitch.

For the CVS250NA specifically, mechanical durability is 20000 cycles conforming to IEC 60947-3 against 25000 cycles conforming to IEC 60947-3 and 15000 cycles conforming to IEC 60947-3 on the other two, and the net weight of 2.4 kg compares with 2.2 kg and 6.05 kg. A larger frame trades fewer rated mechanical cycles for a higher current and making capacity.

Part number Short name Ith Icm alone Net weight
LV516425 CVS160NA 160 A 3.6 kA 2.2 kg
LV525425 CVS250NA 250 A 4.9 kA 2.4 kg
LV540400 CVS400NA 400 A 7.1 kA 6.05 kg

Selection and installation of the LV525425

Check these points before ordering.

  • Current: 250 A Ith, with AC-22A and AC-23A at 250 A.
  • Protection: an upstream circuit breaker or fuse is mandatory; confirm it against the Icm and Icw values above.
  • Space: 105 x 86 x 161 mm and a 35 mm connection pitch.
  • Function: isolation is provided, but there is no visible break and no tripping function.
  • Accessories: handles, auxiliary contacts and terminal shields are separate references; list the ones needed.

Fit it on a flat backplate with front connections, using the cut-out and fixing dimensions of the manufacturer installation instructions, which are not reproduced in the datasheet. Land the cables, check the contact position indicator against the handle, and apply the warning labels required by the site procedure. During shutdowns inspect the terminals for heat marks and clean dust from the housing; operate the handle a few times a year on a lightly loaded circuit so the mechanism does not stick in a dusty room.

Load-break ratings of the CVS250NA LV525425

The datasheet gives the rated operational current Ie as 250 A in both AC-22A and AC-23A, at 220/240 V, 380/415 V and 440 V, 50/60 Hz. AC-22A covers mixed resistive and inductive loads including moderate overloads; AC-23A covers motor loads and other highly inductive loads. Listing both at the full 250 A means it can be applied to a motor feeder without derating from the headline figure, provided the starting duty stays within the stated electrical durability.

Electrical durability is stated as AC-22A: 6500 cycles 415 V AC 50/60 Hz In conforming to IEC 60947-3, and mechanical durability as 20000 cycles conforming to IEC 60947-3. It is therefore an incomer or sectionalising device operated occasionally, not a device for frequent switching of a process load. For frequent switching use a contactor downstream and keep this switch-disconnector as the isolator.

Information to send with an RFQ for the LV525425

Please include in your request:

  • Part number LV525425 and quantity.
  • System voltage, frequency and the upstream protective device already installed or planned.
  • Load type (motor, heater, incomer) so the AC-22A or AC-23A rating can be confirmed.
  • Accessories needed, listed by reference.
  • Delivery location and required documents.

Documents and quotation

The official Schneider Electric datasheet for the LV525425 is attached on this page, so the figures quoted above can be checked line by line against the manufacturer document. Please send the part number LV525425, the quantity and the delivery point in Oman or elsewhere in the GCC, and we will reply with availability and lead time.

Seven Star LLC is an independent supplier based in Muscat. We work independently of the manufacturer; we source, check the reference against the datasheet and quote. Ask for the LV525425 on your RFQ and mention any special packing, marking or documentation needed for the project file.

Datasheets & Documents
  • PDF Datasheet Schneider Electric LV525425 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LV525425 CVS250NA 250 A Switch

Answers from our engineering team on installation, compatibility and integration.

01What is the LV525425?
It is a Schneider Electric EasyPact CVS switch disconnector, short name CVS250NA, three poles, conventional thermal current 250 A, in a fixed backplate version with toggle handle.
02Does the LV525425 protect against short circuit?
No. It has no trip unit. The datasheet gives Icm of 75 kA with an upstream protection circuit breaker and 4.9 kA for the switch-disconnector alone, so upstream protection is required.
03Which utilisation categories does the LV525425 cover?
The datasheet lists AC-22A and AC-23A at 250 A for 220/240 V, 380/415 V and 440 V, 50/60 Hz, and suitability for isolation to IEC 60947-3.
04What are the dimensions and weight of the LV525425?
Width 105 mm, depth 86 mm, height 161 mm, net weight 2.4 kg, connection pitch 35 mm.
05Can Seven Star LLC quote the LV525425 for Oman?
Seven Star LLC is an independent supplier in Muscat and quotes the LV525425 for Oman and the GCC on request. Send the part number and quantity and we will confirm availability and documents.