Schneider Electric CCT15263 Acti9 Outdoor Light Sensor Cell

Description

CCT15263 Acti9 analogue outdoor light sensor cell

The CCT15263 is a wall-mounted outdoor light sensor cell for the Schneider Electric Acti9 twilight switches. It does not switch anything by itself: it is the eye of an IC100, IC2000 or IC2000P+ module, supplied with a 50 m cable, an adjustment range of 2–2000 lux and IP55 protection. Seven Star LLC supplies the CCT15263 in Oman and the GCC as an independent supplier based in Muscat.

The sensor is a replacement or extension item. Use it where an existing twilight switch needs a new cell, or where the cell must sit far from the board, since the datasheet gives 50 m of cable. It is horizontally orientable, so it can be aimed away from lamps whose light would otherwise fool it.

CCT15263 technical specifications

Parameter Specification
Manufacturer / part number Schneider Electric / CCT15263
Range / product name Acti9
Product type Wall mounted cell
Function available Horizontally orientable
Range compatibility Acti9 IC100 twilight switch; Acti9 IC2000 twilight switch; Acti9 IC2000P+ programmable twilight switch with time switch function
Cable length 50 m
Light intensity adjustment 2–2000 lux
Mounting location Outdoor
Dimensions 95 mm x 48 mm x 45 mm (H x W x D)
Net weight 40.5 g
Operating temperature -40–70 °C
Storage / transport temperature -40–70 °C
Relative humidity 100 %
Protection IP55
Warranty 18 months

How the CCT15263 works with the twilight module

A twilight cell measures ambient brightness and passes it to the module on the DIN rail, which compares it with the threshold set on its dial. The datasheet range compatibility lists the Acti9 IC100 twilight switch, the IC2000 twilight switch and the IC2000P+ programmable twilight switch with time-switch function. The cell itself carries no contact rating and no supply: all load switching happens in the module.

Environmental limits are broad: operating and storage temperature of -40–70 °C, relative humidity up to 100 % and IP55. These values suit exposed facade and pole positions, though a sun-baked wall can run hotter than the air temperature.

Positioning and cabling of the CCT15263

Mount the cell on a wall where it sees natural light but not the lamps it controls. Aim it horizontally, away from street lighting, signs and reflective surfaces. Keep the cable run within the 50 m stated on the datasheet and separate from power cables to limit interference.

Dirt reduces the light reaching the sensor, so clean it at inspection intervals. In dusty areas of Oman a clogged cell makes lights switch on early, which wastes energy but is easy to correct.

Modules the CCT15263 can be paired with

Three twilight modules are named as compatible. Two of them have their own datasheets reviewed in this catalogue lane, so their key values are repeated here; the IC100 is named by the datasheet but not described further on this page.

Part number Module Contact Switching current Delay Width
CCT15369 IC2000 1 NO 10 A – 250 V AC pf = 0.6 20 s on; 80 s off 18 mm
CCT15483 IC2000P+ C/O 10 A – 250 V AC pf = 0.6 20–140 s (on); 20–140 s (off) 45 mm

CCT15263 against the other twilight products in this range

Datasheet comparison of the twilight modules and the separate cell:

Part number Type Sensor / equipment Contact Lux range Weight
CCT15285 Twilight switch twilight sensor indoor 1 NO 2–2000 lux 87.5 g
CCT15369 Twilight switch twilight sensor outdoor 1 NO 2–2000 lux 111 g
CCT15483 Programmable twilight switch with time switch function twilight sensor outdoor C/O 2–2000 lux 150 g
CCT15263 (this page) Wall mounted cell n/a n/a 2–2000 lux 40.5 g

Selection checklist for the CCT15263

  • Where is the light measured: indoors, outdoors, or at a remote wall position?
  • Is brightness alone enough, or is a time schedule also needed?
  • Does the supply and load match the module rating on the datasheet?
  • Is the cable length enough between sensor and module?
  • Does the mounting position avoid direct light from the controlled lamps?

Reading the lux scale: a low threshold makes the output respond only in near darkness, while a setting toward the 2000 lux end responds in bright daylight. Pick the threshold from the brightness at which lights are really needed on site, not from the datasheet range alone.

Installation and commissioning of the CCT15263

Install this unit according to its role: mount the cell on the wall, route its cable to the module in the board and set the dial on the module.

Test on site at dusk, check that the output is stable through the delay, and record the final dial position in the board schedule so that a replacement can be set the same way.

If lights switch on too early or too late, clean the cell window first, check that the cable is intact and that the cell is not shaded by a structure, then reset the threshold on the module.

Where the CCT15263 fits in Oman and the GCC

Twilight control suits external lighting for compounds, roads, car parks and facades, and daylight-linked lighting in atria and corridors. Strong sun, dust and sand on a sensor window and high board temperatures are the main local issues: place sensors where they can be cleaned, shade boards and compare the datasheet limits with real conditions.

Lighting circuits in the region often share one supply with signage and security equipment, so record in the board which outputs follow the twilight signal and which do not. A written setting for the dial, the lux threshold chosen and the date of commissioning saves time at the next maintenance visit.

Documents and quotation

The official Schneider Electric datasheet of this unit is attached on this page for download, so every figure above can be checked against the source.

To request a quotation, send us the part number CCT15263, the quantity and the delivery location through the RFQ form. Seven Star LLC replies with availability and lead time.

Other Models in the Se Ic Twilight Range

Seven Star LLC supplies models from the Se Ic Twilight range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric CCT15263 Acti9 Outdoor Light Sensor CellAutomation AccessoriesYou are viewing this model
Schneider Electric CCT15285 Acti9 IC2000 Indoor Twilight SwitchAutomation AccessoriesView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric CCT15263 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric CCT15263 Acti9 Outdoor Light

Answers from our engineering team on installation, compatibility and integration.

01What is the CCT15263?
A wall-mounted outdoor light sensor cell for Schneider Electric Acti9 twilight switches, with a 50 m cable, IP55 protection and an adjustment range of 2…2000 lux.
02Which modules work with the CCT15263?
The datasheet lists the Acti9 IC100 and IC2000 twilight switches and the IC2000P+ programmable twilight switch.
03What temperature range does the CCT15263 tolerate?
-40…70 °C in operation and -40…70 °C in storage and transport.
04Can the CCT15263 switch a load by itself?
No. It is a sensor only and has no switching contact; the load is switched by the twilight module it is connected to.
05How long can the cable of the CCT15263 be?
The datasheet gives a cable length of 50 m.