Schneider Electric CA2KN40U7 TeSys K Relay 4 NO, 230-240 V AC

Description

CA2KN40U7 TeSys K control relay: what the code and the data say

The CA2KN40U7 is a Schneider Electric TeSys K control relay with four normally open contacts and a coil for 230 to 240 V AC at 50/60 Hz. The manufacturer’s title reads: TeSys K control relay – 4 NO – up to 690 V – 230…240 V AC coil. It is a small contactor-style relay in the CAK family, built for the control circuits of machines and panels, not for motor power. Seven Star LLC supplies the CA2KN40U7 in Oman and the GCC as an independent supplier based in Muscat.

Reading the code against the datasheet: CA2K is the device short name of the TeSys K control relay, N40 corresponds to the four-pole arrangement with four NO contacts and no NC, and U7 corresponds to the 230 to 240 V AC 50/60 Hz coil. The same housing exists with other contact arrangements and coil voltages, so the complete CA2KN40U7 must be quoted to avoid a mismatch.

Technical specifications of the CA2KN40U7

Parameter Specification
Manufacturer / part number Schneider Electric / CA2KN40U7
Range / type TeSys K control relay (TeSys CAK, device short name CA2K)
Application Control circuit
Pole contact composition 4 NO
Utilisation categories DC-13; AC-15
Rated operational voltage (Ue) ≤ 690 V, ≤ 400 Hz
Control circuit type / voltage (Uc) AC at 50/60 Hz / 230 to 240 V AC 50/60 Hz
Control voltage limits Drop-out 0.2 to 0.75 Uc; operational 0.8 to 1.15 Uc (at < 50 °C)
Operating time 10 to 20 ms closing and 10 to 20 ms opening (NO contacts)
Inrush / hold-in power 30 VA / 4.5 VA (at 20 °C)
Heat dissipation 1.3 W
Thermal current (Ith) 10 A (at 50 °C)
Rated making capacity 110 A conforming to IEC 60947
Associated fuse 10 A gG (IEC 60947 and VDE 0660)
Insulation voltage (Ui) 690 V IEC 60947 / BS 5424; 750 V VDE 0110 group C; 600 V CSA
Minimum switching 17 V / 5 mA
Mechanical durability / rate 10 Mcycles / 10000 cycles per hour
Immunity to microbreaks 2 ms
Mounting / terminals DIN rail or plate; screw clamp, 0.34 to 4 mm², 1.3 N.m
Dimensions (H x W x D) 58 mm x 45 mm x 57 mm
Net weight 0.18 kg
Degree of protection IP2X
Ambient temperature, operation -25 to 50 °C
Ambient temperature, storage -50 to 80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94
Certifications CB Scheme; CCC; UL; CSA; EAC; CE; UKCA

How the CA2KN40U7 behaves electrically

The coil works from 0.8 to 1.15 times the rated control voltage when the ambient is below 50 °C. With the 230 to 240 V rating this corresponds to roughly 184 V at the lowest point of the 230 V end and 276 V at the highest point of the 240 V end, which is a generous band for a mains supply that fluctuates or sags when large motors start. The relay releases when the coil voltage falls to between 20 and 75 % of Uc.

The datasheet gives 30 VA inrush and 4.5 VA hold-in, which at about 230 V means a pull-in current near 0.13 A and a holding current near 20 mA; these are figures derived from the stated power for sizing a supply or a switching contact, not guaranteed ratings. Operating times are short: 10 to 20 ms for closing and for opening of the NO contacts. The relay also tolerates 2 ms microbreaks in the supply and is rated for up to 10,000 operations per hour, with a mechanical durability of 10 million cycles.

Contacts, loads and protection of the CA2KN40U7

All four contacts are normally open. The datasheet gives a conventional thermal current of 10 A at 50 °C, utilisation categories AC-15 and DC-13, a rated operational voltage of up to 690 V and a rated making capacity of 110 A. The recommended short-circuit protection is a 10 A gG fuse, and the contacts can switch low-level signals down to 17 V and 5 mA, which makes the relay usable for PLC inputs as well as for mains solenoids and contactor coils.

With four NO contacts and no NC, the CA2KN40U7 is well suited to repeating a start signal, a run signal or a trip to four independent circuits. If an interlock needs a normally closed contact, the TeSys K range contains other contact arrangements, and the TeSys D control relays of the CAD series offer 3 NO + 2 NC. The relay is not an overload or protection device: it does not detect current and does not replace a thermal relay or a breaker.

Choosing between the CA2KN40U7 and larger control relays

The TeSys K body is small, 58 mm high, 45 mm wide and 57 mm deep with a net weight of 0.18 kg, which is only about a third of the weight of a TeSys D control relay (0.58 kg for the CAD32 and CAD50 references) and shallower by 27 to 36 mm. That makes it attractive in compact machine panels. The compromise is in the environmental data: operation from -25 to 50 °C against -40 to 60 °C for the TeSys D control relays, an altitude limit of 2000 m without derating against 3000 m, and a mechanical durability of 10 million cycles against 30 million.

Closing and opening times of 10 to 20 ms are far shorter than those of a DC-coil TeSys D relay, which needs 53 to 72 ms to close, so on an AC supply the CA2KN40U7 is comparable with the AC-coil TeSys D relays and much faster than their DC-coil versions. For hot panels or very heavy duty, the CAD family is the safer choice; for a small cabinet on a mains supply, the CAK family is usually adequate.

Mounting, wiring and maintenance of the CA2KN40U7

The CA2KN40U7 clips onto a DIN rail or can be screwed to a plate. Terminals are screw-clamp: one or two cables of 1.5 to 4 mm² solid, 0.75 to 4 mm² flexible with a cable end and 0.34 to 1.5 mm² for the lighter flexible versions, as listed in the datasheet, and a tightening torque of 1.3 N.m with a 6 mm flat, Philips No 2 or Pozidriv No 2 screwdriver. The housing is rated IP2X, protected against touch by a finger but not against dust, so it belongs inside a panel.

Datasheet data on mechanical robustness give vibration resistance of 2 Gn open and 4 Gn closed from 5 to 300 Hz and shocks of 10 Gn open and 15 Gn closed for 11 ms. In commissioning, check the coil voltage at the terminals under load, confirm that all four contacts close together, and tighten the terminals again after the first thermal cycles. The housing material is rated V1 under UL 94 flame retardance in the datasheet, and an 18-month manufacturer warranty is listed.

Where the CA2KN40U7 is used in Oman and the GCC

A four-pole 230 to 240 V AC control relay appears in the control cabinets of pumping stations, air-handling units, packaged compressors, chillers and conveyors, where it repeats signals between a PLC or a thermostat and field devices on the local 240 V single-phase supply. The 240 V rating is the nominal single-phase voltage on the public network in Oman, so the coil connects directly to the local mains and no control transformer is needed.

The main stress in the region is heat: a panel in direct sun can exceed the 50 °C limit of this relay, so plan ventilation and avoid placing it directly above a drive or a power supply. Dust is the second concern, which the IP2X rating does not address, so a filtered enclosure and a regular cleaning during shutdowns will protect the contacts. For a spare, the CA2KN40U7 is a convenient reference to hold because the coil voltage matches the local mains.

Information to send with an RFQ for the CA2KN40U7

  • Full reference CA2KN40U7 and the quantity
  • Coil voltage and frequency seen on the existing relay or the panel drawing
  • Load or signal switched by each of the four contacts (voltage, current, signal level)
  • The panel or machine it must fit, and whether it is a spare, a replacement or a new installation
  • Delivery location in Oman or the GCC and date required

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is worth reading beside the panel drawing before you order.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Teskk Range

Seven Star LLC supplies models from the Se Teskk range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric CA2KN40U7 TeSys K Relay 4 NO, 230-240 V ACContactors & Overload RelaysYou are viewing this model
Schneider Electric CA2SK20B7 TeSys SK Relay 2 NO, 24 V ACContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric CA2KN40U7 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric CA2KN40U7 TeSys K Relay 4 NO,

Answers from our engineering team on installation, compatibility and integration.

01What coil voltage does the CA2KN40U7 use?
The datasheet lists a 230 to 240 V AC coil at 50/60 Hz, operating from 0.8 to 1.15 times the rated voltage below 50 °C.
02How many contacts does the CA2KN40U7 have?
It has four normally open contacts with a conventional thermal current of 10 A at 50 °C, in utilisation categories AC-15 and DC-13.
03How fast is the CA2KN40U7?
The datasheet lists 10 to 20 ms for coil energisation and NO closing, and 10 to 20 ms for coil de-energisation and NO opening.
04What are the size and weight of the CA2KN40U7?
58 mm high, 45 mm wide and 57 mm deep, with a net weight of 0.18 kg.
05What ambient temperature is allowed for the CA2KN40U7?
Operation is listed from -25 to 50 °C and storage from -50 to 80 °C, with an altitude of 2000 m without derating.