Schneider Electric A9P54306 Acti9 iC40N 3P 6 A C MCB

Description

A9P54306: Acti9 iC40N 3P 6 A C-curve miniature circuit breaker

The A9P54306 is a Schneider Electric Acti9 iC40N miniature circuit-breaker, three-pole, rated 6 A with a C curve and a thermal-magnetic trip unit. It is only 54 mm wide on the DIN rail (6 modules of 9 mm), which makes it a compact way to protect final circuits in a distribution board. Seven Star LLC supplies the A9P54306 in Oman and the GCC as an independent supplier based in Muscat.

The title of the reference reads as iC40N (the N performance version of the iC40), 3P for the pole arrangement, 6 A for the rated current and C for the trip curve. This unit is used on three-phase final circuits.

Technical specifications of the A9P54306

Parameter Specification
Manufacturer / part number Schneider Electric / A9P54306
Range / product Acti9 iC40 (device short name iC40N)
Type Miniature circuit-breaker, thermal-magnetic, distribution application
Poles 3P, 3 protected pole(s)
Rated current [In] 6 A
Curve / magnetic trip C curve; 5–10 × In (EN/IEC 60898-1), 8 × In ± 20 % (EN/IEC 60947-2)
Rated operational voltage 400 V AC
Network type AC
Breaking capacity 10 kA Icu (EN/IEC 60947-2); 6000 A Icn at 400 V AC 50/60 Hz (EN/IEC 60898-1)
Service breaking capacity [Ics] 100 % of Icn at 400 V AC 50/60 Hz
Limitation class 3
Isolation Suitable for isolation
Rated insulation / impulse Ui 400 V AC / Uimp 4 kV
Endurance (mechanical / electrical) 20000 cycles / 20000 cycles
Dimensions (H × W × D) 85 × 54 × 74 mm
Net weight 340 g
Terminals Tunnel type, top or bottom; 1–10 mm² flexible, 1–16 mm² rigid
Stripping length / torque 14 mm / 2 N.m
Local signalling ON/OFF indication, trip indicator
Locking Padlocking device
Earth-leakage protection Separate block
Ingress protection IP20; IP40 in a modular enclosure
Operating / storage temperature -25–70 °C / -40–85 °C
Humidity / altitude 95 % at 55 °C / 2000 m
Standards EN/IEC 60898-1, EN/IEC 60947-2
Approvals listed CE BV RINA DNV
Quality labels OVE and AENOR

Breaking capacity and where it fits

The datasheet quotes 10 kA Icu and 6 kA Icn at 400 V AC. The N version of the iC40 raises these to 10 kA Icu and 6 kA Icn against the 6 kA and 4.5 kA of the standard version, so choose it when the prospective short-circuit current at the board is higher. Service breaking capacity is listed at 100 % of Icn for the IEC 60898-1 rating, and the limitation class is 3, meaning a lower let-through energy than classes 1 and 2.

The approval list in the datasheet includes CE, BV, RINA and DNV, which are relevant to marine and offshore enclosures; the quality labels listed for this reference are OVE and AENOR. Check that any project-specific approval you need is on that list before you order.

Typical uses of the A9P54306 in Oman and the GCC

Three-pole iC40N breakers are used on small three-phase loads such as pump motors, fans and compressors fed from sub-boards, and for outgoing circuits in commercial buildings. In the Gulf climate the listed operating range of -25–70 °C and 95 % humidity at 55 °C are suitable for most indoor panels, but a ventilated or air-conditioned room still extends life. The marine approvals in the datasheet also make it a candidate for vessel and offshore accommodation panels.

How the A9P54306 compares with its siblings

The closest references in the same range are listed below for comparison. Same-range siblings share terminals and dimensions per pole; they differ in rating and breaking capacity.

Part number Version Poles Rating Curve
A9P54602 iC40N 1P + N 2 A C

The A9P54602 is the single-pole plus neutral member of the N class at 2 A, whereas the A9P54306 is a three-pole version at 6 A.

Selection checklist and RFQ details for the A9P54306

Check these points first.

  • Poles: 3P; confirm the neutral is to be switched (no, phases only).
  • Rating and curve: 6 A, C curve, against the cable and load inrush.
  • Fault level at the board against 10 kA Icu.
  • Approvals: the project may need BV, RINA or DNV; all three appear in the datasheet.
  • Add-on blocks and busbars: earth-leakage block, padlocking.
  • Enclosure: IP20 alone, or IP40 inside a modular enclosure.

With your enquiry, send:

  • Part number A9P54306 and quantity.
  • Supply voltage, number of phases and prospective fault level.
  • Delivery location and required date.
  • Required approval certificates, if any.

How the A9P54306 trips and what the curve means

A bimetal strip heats under sustained overcurrent and releases the contacts after a delay that shortens as current rises; an electromagnet releases almost instantly once the current passes the magnetic limit. For this unit the C curve places that limit at 5–10 times the rated current to EN/IEC 60898-1, or 8 times with a ± 20 % tolerance to EN/IEC 60947-2. On a 6 A rating the instantaneous threshold is only a few tens of amperes, so a three-phase circuit of small motors or control transformers should be checked for inrush before the C curve is accepted.

Mounting, wiring and add-on blocks for the A9P54306

The breaker clips onto a DIN rail and occupies 6 modules. Tunnel terminals at top and bottom accept 1–10 mm² flexible or 1–16 mm² rigid conductors; strip 14 mm and tighten to 2 N.m. With three poles the 54 mm body covers three phase terminals; a neutral busbar is wired separately because the pole count here protects phases only. A padlocking device holds the toggle in the open position, and an earth-leakage block can be added as a separate module on the supply side where the project requires residual-current protection. Trip indicator and ON/OFF indication make it easy to see from the front which circuit tripped.

Documents and quotation

The manufacturer’s product datasheet for the A9P54306 is attached on this page for reference; it is the document to use when you verify ratings, dimensions and approvals against your own design. It lists the rated values for this exact reference.

To receive a quotation, send the part number A9P54306 with quantity and delivery location in Oman or the GCC. Seven Star LLC replies with availability and lead time as an independent supplier based in Muscat.

Other Models in the Schneider Ic40 Range

Seven Star LLC supplies models from the Schneider Ic40 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric A9P52616 Acti9 iC40 1P + N 16 A C MCBCircuit BreakersView details
Schneider Electric A9P52632 Acti9 iC40 1P + N 32 A C MCBCircuit BreakersView details
Schneider Electric A9P54306 Acti9 iC40N 3P 6 A C MCBCircuit BreakersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric A9P54306 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric A9P54306 Acti9 iC40N 3P 6 A C MCB

Answers from our engineering team on installation, compatibility and integration.

01What is the A9P54306?
It is a Schneider Electric Acti9 iC40N miniature circuit-breaker, 3P, 6 A, C curve, thermal-magnetic, 54 mm wide on a DIN rail.
02What breaking capacity does the A9P54306 have?
The datasheet lists 10 kA Icu to EN/IEC 60947-2 and 6 kA Icn to EN/IEC 60898-1 at 400 V AC.
03Which approvals are listed for the A9P54306?
The datasheet lists CE, BV, RINA and DNV certifications, with quality labels as shown in the specification table on this page.
04Can an earth-leakage block be added to the A9P54306?
Yes, the datasheet lists earth-leakage protection as a separate block. Confirm the exact block reference with the manufacturer's range data.
05What conductor sizes fit the A9P54306?
Top and bottom tunnel terminals accept 1-10 mm2 flexible or 1-16 mm2 rigid conductors with 14 mm stripping and 2 N.m torque.