Schneider Electric 29452 Low-Level Auxiliary Contact
Description
29452: low-level auxiliary contact for circuit breaker status signals
The 29452 is a low-level auxiliary contact for moulded-case and power circuit breakers. In the datasheet it is described as a breaker status contact with one changeover element, listed under the short names SD, SDV, OF and SDE, with local signalling of open/close, relay trip and electrical fault trip, and it clips on to the breaker. Seven Star LLC supplies the 29452 in Oman and the GCC as an independent supplier in Muscat.
The word low-level is the point of this reference. The datasheet gives a minimum load of 1 mA at 4 V DC, against 100 mA at 24 V DC for the standard contact 29450, so it is the contact that stays reliable where the signal is a few volts and a few milliamperes, for example an input to a PLC, a building management gateway or a protection relay logic input.
29452 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / 29452 |
| Description | low level auxiliary contact, circuit breaker status OF/SD/SDE/SDV, 1 changeover contact type |
| Product type | Auxiliary contact |
| Device short names | SD; SDV; OF; SDE |
| Application | Breaker status monitoring |
| Contact type | Low level |
| Signal contacts composition | 1 NO/NC |
| Fault type | General electric fault |
| Local signalling | ON/OFF indication for open/close; Trip indicator for relay trip indicator; Fault trip for electrical fault |
| Mounting mode | Clip-on |
| Conventional free-air thermal current [Ith] | 5A |
| Minimum load | 1 mA at 4 V DC |
| Range compatibility | ComPact NS630b to 1600, ComPact NS1600b to 3200, ComPact ComPacT INS, ComPact Compact INV, ComPact NSX, EasyPact CVS, PowerPact Multistandard, ComPact NSX DC, Galaxy PX, Galaxy VL, Galaxy VM, Galaxy VS, Galaxy VX |
| Spare part category | Spare part for Compact NS630b to 1600; Spare part for Compact NS1600b to 3200 |
Switching ratings of the 29452
The datasheet gives the conventional thermal current as 5A and lists breaking capacities by utilisation category. In category AC-12 (resistive control loads) the contact breaks 5 A at 24 V AC and 5 A at 220 to 240 V AC. In AC-15, which describes inductive loads such as contactor coils and relays, the figure falls with voltage: 3 A at 24 V, 2 A at 220 to 240 V and 1.5 A at 380 to 440 V.
On direct current the contact is rated 5 A at 24 V DC in DC-12 and 0.3 A at 250 V DC in DC-12, while in DC-14 (inductive DC loads) it is 1 A at 24 V DC and only 0.03 A at 250 V DC.
The full list is in the table below. For any real circuit, work from the voltage and the load category first and the current second, because a contact that happily switches 6 A of resistive load can fail quickly on a small inductive DC coil.
| Category | Voltage | Current (A) |
|---|---|---|
| AC-12 | 24 V AC | 5 |
| AC-12 | 48 V AC | 5 |
| AC-12 | 110 V AC | 5 |
| AC-12 | 220/240 V AC | 5 |
| AC-12 | 380/440 V AC | 5 |
| AC-12 | 480 V AC | 5 |
| AC-15 | 24 V AC | 3 |
| AC-15 | 48 V AC | 3 |
| AC-15 | 110 V AC | 2.5 |
| AC-15 | 220/240 V AC | 2 |
| AC-15 | 380/440 V AC | 1.5 |
| AC-15 | 480 V AC | 1 |
| DC-12 | 24 V DC | 5 |
| DC-12 | 48 V DC | 2.5 |
| DC-12 | 110 V DC | 0.6 |
| DC-12 | 250 V DC | 0.3 |
| DC-14 | 24 V DC | 1 |
| DC-14 | 48 V DC | 0.2 |
| DC-14 | 110 V DC | 0.05 |
| DC-14 | 250 V DC | 0.03 |
Where the 29452 fits: the breaker ranges and Galaxy compatibility
Two compatibility groups are listed. The first matches the standard accessory range: ComPact NS630b to 1600, ComPact NS1600b to 3200, ComPact ComPacT INS, ComPact Compact INV, ComPact NSX, EasyPact CVS, PowerPact Multistandard, ComPact NSX DC. The second is specific to this low-level version and lists Galaxy PX, Galaxy VL, Galaxy VM, Galaxy VS, Galaxy VX.
The datasheet also describes the part as a spare for ComPact NS630b to 1600 and for NS1600b to 3200. Always check that the accessory slot of your breaker type accepts it before ordering, because the datasheet lists four functions under one reference and the breaker documentation tells you which one a given slot reports.
Standard or low-level: choosing between 29452 and 29450
The two parts are electrically similar in rating at higher voltages, so the choice is driven by load. Use the 29452 when the contact feeds a high-impedance electronic input, because a standard contact is specified with a higher minimum load and may give unreliable readings at such tiny currents. Use 29450, with its spring terminals (Spring 0.5 to 1.5 mm² (20 AWG to 16 AWG)), when the contact drives a contactor coil, a lamp or an indicator relay at 24 V or above.
The standard contact is rated up to 6 A in AC-12 at 660 to 690 V, a voltage the low-level version does not list, so for a 690 V circuit the standard contact is the one that carries the rating.
Wiring and commissioning notes for the 29452
Wire the contact before the breaker is energised and label the function (open/close, trip or fault trip) on the terminal block, because one reference covers several functions. After wiring, operate the breaker, and trip it by a method your site procedure allows, to check that the signal reaches the PLC or alarm panel in the correct state.
Keep the signal cable away from power cables and use ferrules where the terminal design requires them. For a low level contact the practical rule is simple: stay below the category rating for your voltage, and do not ask the 29452 to carry more than its 5A thermal current.
Typical applications of the 29452 in Oman and the GCC
Breaker status contacts feed motor control centres, main and sub-distribution boards, generator and transformer incomers and the SCADA or building management systems that watch them. In oil and gas, power and water installations in Oman the 29452 is usually specified on the signal side of the board, where operators need to know if an incomer is open, closed or tripped.
In hot and dusty sites the main wear point is the clip-on connection and the wiring, so inspect it at each shutdown. Keep spares of the contacts for critical breakers, because a missing status signal can leave a control room blind to a trip.
Ordering checklist for the 29452
- Breaker or switch type and rating that will carry the contact.
- Function wanted: OF, SD, SDE or SDV.
- Load voltage and category (AC-15, DC-13 and so on) against the table above.
- Terminal type: check the wiring method in the datasheet.
- Quantity per breaker and number of breakers.
- Status: new installation or spare for an existing breaker.
RFQ details for the 29452
Send the part number 29452, the quantity, the breaker model and the control voltage, and we will confirm availability and a quotation. A photograph of the existing contact is welcome when the contact replaces one in service.
Documents and quotation
A datasheet for this product is attached on this page. It lists the ratings and dimensions summarised above and is the document to check against your drawings and load calculations.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Breaker Aux Range
Seven Star LLC supplies models from the Se Breaker Aux range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric 29450 Standard Auxiliary Contact, Spring | Circuit Breakers | View details |
| Schneider Electric 29452 Low-Level Auxiliary Contact | Circuit Breakers | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric 29452 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric 29452 Low-Level Auxiliary Contact
Answers from our engineering team on installation, compatibility and integration.
01What is the 29452 used for?
It reports the status of a circuit breaker, as OF, SD, SDE or SDV, using one changeover contact that clips on to the breaker.
02What is the minimum load of the 29452?
The datasheet gives 1 mA at 4 V DC. See the datasheet linked on this page for the full figures.
03Which breakers are compatible with the 29452?
The datasheet lists ComPact NS630b to 1600, ComPact NS1600b to 3200, ComPact ComPacT INS, ComPact Compact INV, ComPact NSX, EasyPact CVS, PowerPact Multistandard, ComPact NSX DC, Galaxy PX, Galaxy VL, Galaxy VM, Galaxy VS, Galaxy VX. Check the breaker documentation for the slot.
04What is the thermal current of the 29452?
The conventional free-air thermal current is 5A, with breaking capacities listed per utilisation category.
05How is the 29452 connected?
The datasheet does not give a terminal size for this contact, so check the wiring detail with the breaker documentation.


















Reviews
There are no reviews yet.