Description
Samson 36-8 safety excess pressure valve (SEV)
The Samson 36-8 is a self-operated safety excess pressure valve. It keeps the upstream pressure at an adjusted set point by opening when the pressure rises above that value, and it needs no electricity or compressed air. According to datasheet T 2546-2 the range covers valve sizes DN 15 to 100, pressure ratings PN 16 to 40, set points from 2 to 11 bar, and water or liquids up to 150 °C. The regulator is type-tested by TÜV for water.
The safety character comes from the actuator: two diaphragms work independently, so if the operating diaphragm ruptures the regulator keeps working and an indicator shows the damage. Seven Star LLC supplies the Samson 36-8 in Oman and the GCC as an independent supplier in Muscat.
What the 36-8 name means
In Samson pressure-regulator naming, the Series 36 includes safety devices. The 36-8 is the excess pressure version (SEV) that controls the upstream pressure, while the related 36-4 is a safety shut-off valve with a pressure reducer. The datasheet states that the 36-8 is type-tested according to the AGFW document FW 506 and ordering text requires DN, body material, PN and the set point range.
36-8 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Samson / 36-8 (Type 36-8 safety excess pressure valve, datasheet T 2546-2) |
| Valve size | DN 15, 20, 25, 32, 40, 50, 65, 80, 100 |
| Kvs coefficient | 4, 6.3, 8.0, 16, 20, 32, 50, 80, 125 (by size) |
| Pressure rating | PN 16, 25 or 40 |
| Set point ranges | 2.0 to 4.4 bar; 2.4 to 6.6 bar; 6 to 11 bar |
| Max. differential pressure | 25 bar up to DN 50; 20 bar at DN 65 and 80; 16 bar at DN 100 |
| Temperature | Up to 150 °C; media water and liquids |
| Leakage class (IEC 60534-4) | ≤ 0.05 % of Kvs |
| Overloading | 12 bar on one side |
| Body material | Cast iron EN-GJL-250 (PN 16), spheroidal graphite iron EN-GJS-400-18-LT (PN 25), cast steel 1.0619 (PN 40) |
| Trim | Stainless steel seat and balanced plug with PTFE soft seal; stainless steel balancing bellows and bellows seal |
| Actuator | Two independent EPDM fabric-reinforced diaphragms; sheet steel diaphragm cases; diaphragm rupture indicator or optional pressure switch |
| Weight | Approx. 13 kg (DN 15, PN 16) to 57.5 kg (DN 100, PN 16) |
How the 36-8 holds upstream pressure
The pressure to be controlled travels through a control line to the diaphragm, where it is turned into a positioning force. That force acts against the set point springs. The plug stem and plug move to open the valve when the upstream pressure exceeds the spring setting, and the position of the plug decides the flow through the gap between plug and seat. The plug is balanced with a bellows, so pressure changes at the valve have little effect on control.
The two-diaphragm design is the key safety feature. A red mark appears at the intermediate ring if the operating diaphragm ruptures, and an optional pressure switch can send an optical or acoustic signal to a control room. A stainless steel bellows seals the stem without friction.
Where the 36-8 fits and related Samson regulators
Typical partners are the 36-4 safety shut-off valve with pressure reducer for the same duty on the reducing side, and the 33-1 and 33-7 valves for gas and larger sizes. For general pressure control without the safety diaphragm, the 41-73 universal excess pressure valve and the 2406 are alternatives. The 36-8 is intended mainly for heating and district-cooling networks or other liquid systems that need safety-approved pressure limiting without auxiliary energy.
36-8 selection and ordering checklist
- Medium and maximum temperature, up to 150 °C.
- Valve size and Kvs from sizing, with the required differential pressure.
- Pressure rating PN 16, 25 or 40, which fixes body material.
- Set point range among 2.0 to 4.4, 2.4 to 6.6 and 6 to 11 bar.
- Diaphragm rupture indicator or pressure switch, and the type-test mark for water if the project asks for it.
Installation, commissioning and maintenance of the 36-8
Install the regulator in a horizontal pipeline with the flow in the direction of the arrow and the actuator suspended downward. Connect the control line as shown in the installation instructions EB 2546-2. Set the pressure with the set point adjuster and check it against a gauge during commissioning.
Service is limited: inspect the diaphragm rupture indicator at plant rounds, and open the actuator only with the line depressurized. If the indicator shows red, the regulator still works but the diaphragm assembly should be replaced at the next opportunity.
Typical applications of the 36-8 in Oman and the GCC
In the Gulf, hot water and chilled water networks feed district cooling plants, hospitals and large buildings, and pressure limiting there protects heat exchangers and pipework. The 36-8 can serve hot-water loops up to 150 °C, boiler feed systems, and utility headers at industrial sites, where self-operated devices remove the need for power and instrument air at remote points.
Sizing note: choose the nominal size from the Kvs table and the flow that must be discharged, then confirm that the differential pressure across the valve stays below the permitted value (25 bar to DN 50, 20 bar at DN 65 and 80, 16 bar at DN 100). The 12 bar one-sided overloading limit applies to the actuator and should be checked against the highest pressure the line can see during upsets.
Information to send with an RFQ for the 36-8
- Medium, temperature, flow range and set pressure.
- Size, PN and body material preferred.
- Differential pressure and downstream protection need.
- Indicator or pressure switch option.
- Quantity and delivery location.
Site conditions in Oman for the 36-8
Valves and their accessories in Oman work in demanding conditions: high ambient temperatures, direct sun on outdoor pipe racks, dust, and corrosive coastal air at many oil, gas and water sites. When you specify the 36-8, confirm the pressure and temperature ratings, body and trim materials and any sour-service or hazardous-area requirements against the actual line data, and check that seals and soft parts suit the process medium and the full temperature range.
For reliable operation, plan access for maintenance, define which spare parts are kept on site, and record the configuration of each installed 36-8. Sending the complete process data sheet with your RFQ allows the selection to be checked before the order is placed.
Documents and quotation
The Samson datasheet T 2546-2 for the 36-8 is attached on this page.
Send the set point, size and medium, and Seven Star LLC will quote the Samson 36-8 safety excess pressure valve.
Other Models in the Samson Self Operated Regulators Range
Seven Star LLC supplies models from the Samson Self Operated Regulators range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Samson Type 41-23 Universal Pressure Reducing Valve | Regulators | View details |
| Samson 2406 Excess Pressure Valve DN 15-50 PN 16-40 | Regulators | View details |
| Samson 2371 Hygienic Pressure Reducing Valve DN 15-50 | Regulators | View details |
| Samson Type 46-6 Differential Pressure Regulator with Flow Limit | Regulators | View details |
| Samson Series 43 Self-Operated Temperature Regulators | Regulators | View details |
| Samson Type 33-7 Pilot-Operated Excess Pressure Valve DN 65-250 | Regulators | View details |
| Samson Type 47-5 Flow and Differential Pressure Regulator | Regulators | View details |
| Samson Type 42-34 Differential Pressure Regulator DN 15-250 | Regulators | View details |
| Samson Type 2040 Safety Temperature Monitor for Cryogenic Gas | Regulators | View details |
| Samson 36-8 Safety Excess Pressure Valve DN 15-100 | Regulators | You are viewing this model |
| Samson 45-9 Self-Operated Flow Regulator DN 15-50 | Regulators | View details |
| Samson 45-6 Differential Pressure Regulator for Bypass Pipes | Regulators | View details |
Datasheets & Documents
- Datasheet Samson 36-8 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SAMSON is a German manufacturer of control valves, actuators, positioners and self-operated regulators. Hermann Sandvoss founded the company in Düsseldorf on 1 April 1907, and its first important product was a thermostatic valve that controlled temperature without external power. After moves to Mannheim, SAMSON settled in Frankfurt am Main in 1916, where SAMSON AG is still headquartered.
Seven Star LLC supplies Samson control valves, pneumatic actuators and positioners to process plants in Oman, including the types listed on this page and their replacement units.
Samson company profile
| Founded | 1 April 1907, Düsseldorf, by Hermann Sandvoss, as VULCAN Technische Apparate Baugesellschaft; products sold under the SAMSON name |
|---|---|
| Headquarters | Frankfurt am Main, Germany, since 1916 |
| Legal form | SAMSON AG |
| First product | A self-operated thermostatic valve |
| Group brands | SAMSON together with PFEIFFER, LEUSCH, VETEC and AIR TORQUE |
| Product families | Globe valves such as Type 3241, rotary and butterfly valves, 3271 and 3277 pneumatic actuators, 3730 and 3731 positioners, self-operated pressure and temperature regulators |
Milestones
- 1907: Hermann Sandvoss founds the company in Düsseldorf.
- 1909: It is re-established as SAMSON Apparatebau GmbH.
- 1916: After a period in Mannheim, the company moves to Frankfurt am Main.
- 1975: The name becomes SAMSON Mess- und Regeltechnik.
Samson valve, actuator and positioner types
Samson builds a control valve from modules. The Type 3241 globe valve is the general-service body of Series 240, and the Type 3251 is the Series 250 body for higher pressure ratings. Either one is combined with a Type 3271 pneumatic diaphragm actuator or a Type 3277, whose yoke allows the positioner to be attached directly with a concealed travel linkage.
Among the positioners listed are the Type 3725 and the Type 3730 family: the 3730-1 as the basic electropneumatic version, sold in its current generation as TROVIS 3730-1, and the 3730-3 with HART communication and valve diagnostics. Samson also makes PROFIBUS PA and FOUNDATION fieldbus variants in the same family, plus self-operated pressure and temperature regulators.
Where Samson valves are used
Samson control valves throttle steam, gas and liquids in chemical and petrochemical units, refineries, gas processing, power stations, water and desalination plants, and food production. Many reach site as part of a skid or package, so the plant instrument team often meets them first when a positioner or actuator needs replacing. We supply these items to end users and contractors throughout the GCC.
Samson products we list
Ordering Samson parts: what we need
Every Samson device has a nameplate with the type, a configuration ID (Var-ID) and a serial number. A photo of that plate is the surest route to an exact match. Without it, please send:
- Valve: type, DN or NPS, pressure rating, body and trim material, Kvs or Cv, plug and seat style, packing and bonnet type
- Actuator: type, effective area in cm², bench range, fail action and travel
- Positioner: full type code including Ex protection, communication and options such as limit switches or position transmitter
We check the code against Samson documentation and provide the manufacturer's data sheet on request.
Facts checked against SAMSON's corporate chronicle and press material, October 2026.
Browse Samson products by category: Control Valves, Valve Positioner, Valve Actuator.
FAQ
Questions about the Samson 36-8 Safety Excess Pressure Valve DN 15-100
Answers from our engineering team on installation, compatibility and integration.
01What is the Samson 36-8?
It is a self-operated safety excess pressure valve (SEV) for water and liquids up to 150 °C, with set points from 2 to 11 bar and sizes DN 15 to 100.
02What makes the 36-8 a safety valve?
The actuator has two independent diaphragms. If the operating diaphragm ruptures, the regulator continues to work and an indicator, or an optional pressure switch, shows the damage.
03Does it need power or compressed air?
No. It is a proportional regulator that uses the controlled pressure itself as the energy source and needs no auxiliary energy.
04Which standards does it refer to?
The datasheet states it is type-tested by TÜV for water and complies with AGFW document FW 506 for district heating.
05What set point ranges are available?
Three spring ranges are listed: 2.0 to 4.4 bar, 2.4 to 6.6 bar and 6 to 11 bar. The range is stated in the order.