Brand:

Parker D1VW004CNJW NG06 Solenoid Valve, Tank-Open Centre

Description

D1VW004CNJW NG06 valve with A and B open to tank in centre

The Parker D1VW004CNJW is a three-position, double-solenoid directional valve in the NG06 (CETOP 03 / NFPA D03) size from the D1VW series. What sets it apart from the more common blocked-centre D1VW001 is spool 004. In the centre position, the catalogue flow table lists paths from A to T and from B to T while P has no connection to either working port, so the actuator ports are relieved to tank whenever both coils are off. Seven Star LLC supplies the D1VW004CNJW in Oman and the GCC. The ratings are those of the whole series: 350 bar on P, A and B, 210 bar on T, and up to 80 l/min.

Reading the part number D1VW004CNJW

D is directional control valve, 1 is NG06, V is the 3-chamber body and W the wet-pin solenoid. 004 is the spool type, C is the three-position, spring-centred spool position, N is NBR seals, J is 24 V DC and W is the EN 175301-803 connector without plug. The empty solenoid-option field means a standard manual override on each solenoid. In the D1VW listing, the spool code decides the centre behaviour, while the letter that follows decides whether the valve is a three-position spring-centred type (C), or one of the two-position styles such as E, F, K, M, B, D or H.

D1VW004CNJW technical specifications

Parameter Specification
Manufacturer / part number Parker D1VW004CNJW
Spool type / position 004 / C: three positions, spring offset in position 0, operated in position a or b
Centre position (spool 004) A to T and B to T connected; P not connected to a working port
Seals NBR (code N)
Solenoid voltage 24 V DC (code J), 1.29 A hold current, 31 W
Weight 2.1 kg (two solenoids)
Valve family Directional spool valve, series D1VW, 3-chamber body with wet-pin threaded-in-tube solenoids
Actuation Solenoid, direct operated
Nominal size / interface DIN NG06 / CETOP 03 / NFPA D03; DIN 24340 A6, ISO 4401, CETOP RP 121-H
Mounting Subplate, any orientation, horizontal preferred
Maximum operating pressure P, A, B: 350 bar; T: 210 bar (DC solenoids)
Maximum flow 80 l/min (limited by the shift-limit curve of the chosen spool)
Fluid Mineral hydraulic oil to DIN 51524; viscosity 2.8 to 400 mm²/s, 30 to 80 recommended
Cleanliness ISO 4406 18/16/13
Ambient temperature −25 to +60 °C
Duty ratio / switching frequency 100 % ED; up to 15,000 switches per hour
Protection class IP65 with the plug-in connector correctly fitted
Electrical connection Connector to EN 175301-803 (plug ordered separately)

What the D1VW004CNJW does with a load

With both solenoids off, the springs centre the spool and the two actuator lines drain to tank. The pump flow is blocked at the valve in this position, so a fixed pump will build pressure against its relief valve unless an unloading arrangement is added elsewhere; a variable pump simply destroks. Draining A and B lets a double-acting cylinder or a hydraulic motor move freely under external force, and removes trapped pressure so that tooling can be moved by hand or a load can be lowered by gravity when the circuit allows it. Position a connects P to B and A to T, and position b connects P to A and B to T, with the pressure-drop figures listed in the catalogue for each path.

Because the centre position does not hold a load, spool 004 is not suited to an overhead cylinder or a vertical axis unless a pilot-operated check valve or a counterbalance valve holds the load. Think of the tank-open centre as a release function, as on clamps and presses that must unload when the power is cut.

Shift limits and response for the D1VW004CNJW

The catalogue gives a separate shift-limit curve for each spool type, and spool 004 has its own line on the DC and AC charts. For a standard DC solenoid the energise time is 45 to 60 ms and the de-energise time 20 to 30 ms. Soft-shift orifices S2 (0.5 mm) and S3 (0.75 mm) are available for DC valves where hydraulic shock must be reduced, with response times in the range of hundreds of milliseconds, but they are a different part number from the D1VW004CNJW. Fluid viscosity of 30 to 80 mm²/s and a clean ISO 4406 18/16/13 give the best repeatability.

Comparing D1VW004CNJW with its D1VW relatives

Spool Centre position (catalogue table) Typical role
001 No centre paths listed Blocked centre: holds the actuator ports closed
002 P to A, P to B, A to T, B to T, P to T all listed Open centre: pump unloads to tank
004 A to T and B to T listed Tank-open actuator ports, P blocked
006 P to A and P to B listed Pressure on both working ports

The D1VW004CNJW therefore belongs between the blocked and the open-centre variants in function. Always confirm the symbol in the catalogue because the table above describes the flow paths, not the symbol drawing.

Selection and ordering checklist for D1VW004CNJW

  • Does the circuit need the actuator ports vented to tank at rest? If not, choose spool 001 or a different one.
  • Check load holding with check or counterbalance valves.
  • Supply voltage code J for 24 V DC; other voltage codes are separate part numbers.
  • NBR seals for mineral oil; choose the V code for FPM.
  • Order connectors and NG06 mounting screws separately.
  • Verify the working flow against the shift-limit curve.

Installation and service of the D1VW004CNJW

Mount on an NG06 subplate with the supplied seals and four M5 x 30 screws at 7.6 Nm ± 15 %. Allow 15 mm clearance beside the connector. Wire the solenoids with 3 x 1.5 mm² cable and connect the protective conductor. The standard manual override lets you shift the spool during commissioning; use it with the pump at low pressure and confirm that the actuator moves in the expected direction. If the valve fails to centre, check for contamination or a damaged spring, and check that the tank line pressure stays within the 210 bar limit, with a lower value being safer.

Applications in Oman and the GCC

Tank-open centre valves of this kind appear on hydraulic motors for conveyors, mixers and rotating tooling that must free-wheel, on clamping fixtures, and on small presses and test jigs. In Oman and the GCC the D1VW004CNJW suits workshop equipment, fabrication yards and maintenance skids where heat and dust require a sealed solenoid with an IP65 connector.

Information to send with an RFQ for D1VW004CNJW

  • Part number D1VW004CNJW and quantity.
  • Circuit symbol or drawing, if it is a replacement.
  • Fluid, temperature, pressure and flow.
  • Connectors and subplates needed.
  • Delivery destination.

Documents and quotation

The Parker D1VW catalogue with the ordering code, spool table, shift limits and dimensions is attached on this page.

Seven Star LLC supplies Parker hydraulic valves in Oman and the GCC. Send us the part number D1VW004CNJW and your quantity and we will reply with availability and a quotation.

Other Models in the Parker D1vw Ng06 Range

Seven Star LLC supplies models from the Parker D1vw Ng06 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Parker D1VW001CNJW NG06 Solenoid Directional Valve 24 V DCHydraulic Valves & ComponentsView details
Parker D1VW001CVJW NG06 Solenoid Valve, FPM Seals, 24 V DCHydraulic Valves & ComponentsView details
Parker D1VW004CNJW NG06 Solenoid Valve, Tank-Open CentreHydraulic Valves & ComponentsYou are viewing this model
Datasheets & Documents
  • PDF Catalog Parker D1VW Directional Control Valve Catalogue Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker D1VW004CNJW NG06 Solenoid Valve, Tank-Open

Answers from our engineering team on installation, compatibility and integration.

01What is special about spool 004 in the D1VW004CNJW?
In the centre position, the catalogue lists flow paths from A to T and from B to T, while P is not connected to the working ports, so the actuator lines drain to tank.
02Can I use it to hold a vertical load?
Not on its own. The actuator ports are open to tank in the centre position, so a load-holding valve such as a pilot-operated check or counterbalance valve is needed.
03What voltage does the D1VW004CNJW use?
It uses 24 V DC solenoids (code J) at 1.29 A and 31 W each. The catalogue lists other voltages as separate codes.
04What size is the valve?
It is NG06 (CETOP 03 / NFPA D03) with the DIN 24340 A6 and ISO 4401 mounting pattern, rated to 350 bar on P, A and B.
05Does it include the electrical plugs?
No. The W in the part number denotes the EN 175301-803 connection without plug, so the connectors must be ordered separately.