Brand:

Parker D1FPE55HA9NB50 NG06 Proportional Servo Valve 25 l/min

Description

D1FPE55HA9NB50 NG06 proportional valve with VCD actuator

The Parker D1FPE55HA9NB50 is a direct operated servo proportional directional valve in the NG06 size. It belongs to the D1FP range, in which a VCD actuator moves the spool without a pilot stage, giving servo-valve-class dynamics from a valve that bolts onto a standard CETOP 03 interface. Onboard electronics read a ±10 V command, close the spool-position loop inside the valve and drive the actuator. The D1FPE55HA9NB50 uses an underlap spool rated at 25 l/min per metering edge at 35 bar and is meant for accurate motion and pressure control on hydraulic axes. Seven Star LLC supplies the D1FPE55HA9NB50 in Oman and the GCC.

Decoding the part number D1FPE55HA9NB50

Following the catalogue ordering table: D1FP is the series, with D for directional valve, 1 for NG06, F for proportional control and P for the VCD actuator. E55H is the spool: E55 is an underlap spool and H sets 25 l/min per control edge at a 35 bar pressure drop. The next letter, A, selects the spool position on power-down, here a defined position with approximately 10 % opening, which the product page lists as P to A. The digit 9 means the Y-port is plugged, N stands for NBR seals, and B selects the 0 to ±10 V command signal. The digit 5 selects the 11 + PE electrical connection, and the final 0 is the spool/sleeve design code that is not needed for ordering.

D1FPE55HA9NB50 technical specifications

Parameter Specification
Manufacturer / part number Parker D1FPE55HA9NB50
Series D1FP direct operated servo proportional directional valve, VCD actuator
Size / interface NG06 / CETOP 03 / NFPA D03; DIN 24340, ISO 4401, CETOP RP121
Spool E55H: underlap spool, 25 l/min nominal at 35 bar per metering edge
Spool position on power-down A: approx. 10 % opening, P to A
Maximum flow 90 l/min at 350 bar over two control edges
Maximum pressure P, A, B: 350 bar; T: 35 bar internal drain, 350 bar external drain; Y: 35 bar
Step response (100 % step) < 3.5 ms
Frequency response 350 Hz at ±5 % signal (−3 dB, −90°)
Hysteresis / sensitivity < 0.05 % / < 0.03 %
Command signal Code B: 0 to ±10 V
Electronics / connection Onboard; code 5: 11 + PE to EN 175201-804, with enable input
Supply 24 V DC nominal (22 to 30 V), 3.5 A max, 4 A medium-lag fuse
Seals / fluid NBR; hydraulic oil to DIN 51524 to 535
Fluid temperature / ambient −25 to +60 °C (NBR) / −20 to +60 °C
Viscosity / cleanliness 20 to 400 mm²/s / ISO 4406 18/16/13
Protection class / weight IP65 / 3.6 kg

How the D1FPE55HA9NB50 controls the spool

The VCD actuator lets the spool follow rapidly changing commands. The catalogue gives a step response below 3.5 ms for a full step, a 350 Hz frequency response at a small ±5 % signal and hysteresis below 0.05 %, measured with a 100 bar pressure drop over two control edges. At power-down the spool moves to a defined position, so a controlled state exists if the supply fails. The catalogue notes that this cannot be guaranteed where a single flow path on the A to T or B to T edge sees a pressure drop above 120 bar, or where the oil is contaminated.

Unlike a solenoid-driven valve, the D1FPE55HA9NB50 has no flow limit due to flow forces up to 350 bar pressure drop across the valve, which lets a small valve replace an NG10 valve in some applications. The Y-port plug sets how tank pressure is handled: it must be removed when tank pressure exceeds 35 bar, and then the port is connected to tank.

Connecting and wiring the D1FPE55HA9NB50

The code 5 electronics use 11 + PE pins per EN 175201-804. The catalogue lists an 8 x 1.0 mm² (AWG 16) overall-braid shielded cable up to 50 m, a 24 V supply tolerance of 22 to 30 V with electrical shut-off below 19 V, and ripple below 5 %. The command input is a 100 kOhm differential input with a maximum of 30 V against PE on the terminals defined for code 5. An enable signal is available on this code: low is −3 to +5 V and high 11 to 30 V with 3 mA input current. Diagnostic output is ±10 V or 4 to 20 mA. Keep the signal cable away from motor and drive cables and connect the shield at the controller end following EMC practice; the valve is tested to EN 61000-6-2 and EN 61000-6-4.

Compatible and related parts to D1FPE55HA9NB50

Within the D1FP family the spool code changes flow: B, C, F, G, H, M and P cover 3, 6, 12, 16, 25, 40 and 60 l/min at 35 bar per edge. The E50 zerolap, E55 underlap, E01 and E02 overlap series differ in leakage and centre behaviour, while the B-series spools (QB = QA/2) are the ones with unequal flow on the two sides. The NG10 sibling D3FP, for example the D3FPE02YC9NB70, covers 50 and 100 l/min. Other D1FP command codes are E (±20 mA), S (4 to 20 mA), Y (±50 mA) and W (adjustable), and code 0 gives the 6 + PE connection. For closed-loop axes, Parker offers separate E-modules and servo drives that work with these valves.

Selection checklist for D1FPE55HA9NB50

  • Required flow at the actual pressure drop: scale the nominal figure with the square root of the pressure ratio.
  • Underlap versus zerolap or overlap: underlap and zerolap spools leak more than overlap spools (the catalogue gives below 400 ml/min at 100 bar for zerolap and below 50 ml/min for overlap), so check this against the pump size.
  • Power-down behaviour: P to A, B to T or centre, depending on the safe state of the machine.
  • Command signal and connector match your controller; confirm enable logic if used.
  • Fluid, filtration and temperature within the stated limits.
  • Tank pressure: remove the Y-port plug above 35 bar and plan a drain line.

Installation and maintenance of the D1FPE55HA9NB50

Install on a ground, flat NG06 mounting face with unrestricted orientation. Because a VCD valve is sensitive to dirt, flush the circuit and use pressure and return filters to ISO 4406 18/16/13 or better. Do not open the valve or adjust factory-set parameters; use the IO-Link and NFC interfaces described in the catalogue for parameter changes where applicable. Check cable shielding and supply ripple first when jitter appears, then inspect oil cleanliness. When valves are used in safety-related parts of a machine, the catalogue requires that the electronics supply be switched off through a suitable element of sufficient reliability.

Applications in Oman and the GCC

Valves of this class suit injection moulding and press lines, test benches, steel and metal-forming equipment, turbine and valve actuator test rigs, and any hydraulic axis that needs repeatable positioning or force control. For plants in Oman, the 60 °C ambient limit and clean-oil needs mean the valve should sit in a ventilated, dust-protected cabinet or hydraulic manifold area.

Information to send with an RFQ for D1FPE55HA9NB50

  • Full part number D1FPE55HA9NB50 and quantity.
  • Controller and command signal, enable and diagnostic needs.
  • Operating pressure, tank pressure and maximum flow.
  • Fluid and filtration level.
  • Cables and connectors required.
  • Delivery destination.

Documents and quotation

The Parker D1FP catalogue with the ordering code, spool tables, technical data and flow characteristics is attached on this page.

Seven Star LLC supplies Parker hydraulic valves in Oman and the GCC. Send the part number D1FPE55HA9NB50 with your quantity and we will confirm availability and quote.

Other Models in the Parker D1fp Ng06 Range

Seven Star LLC supplies models from the Parker D1fp Ng06 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Parker D1FPE55HA9NB50 NG06 Proportional Servo Valve 25 l/minHydraulic Valves & ComponentsYou are viewing this model
Parker D3FPE02YC9NB70 NG10 Proportional Servo Valve 100 l/minHydraulic Valves & ComponentsView details
Datasheets & Documents
  • PDF Catalog Parker D1FP Proportional Valve Catalogue Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker D1FPE55HA9NB50 NG06 Proportional Servo Valve

Answers from our engineering team on installation, compatibility and integration.

01What does E55H mean in D1FPE55HA9NB50?
E55 is an underlap spool and H is the flow size, 25 l/min per metering edge at a 35 bar pressure drop, according to the D1FP ordering table.
02How fast is the D1FP valve?
The catalogue gives a step response below 3.5 ms for a 100 % step and a frequency response of 350 Hz at a plus or minus 5 % signal, with hysteresis below 0.05 %.
03What command signal does the D1FPE55HA9NB50 use?
The letter B means a 0 to plus or minus 10 V command. Other codes are E for plus or minus 20 mA, S for 4 to 20 mA, Y for plus or minus 50 mA and W for an adjustable input.
04What happens at power-down?
The spool moves to a defined position selected by the A in the code, approximately 10 % open with P to A. The catalogue notes this is not guaranteed with a single flow path above 120 bar drop or contaminated oil.
05What is the maximum pressure and tank pressure?
Ports P, A and B are rated to 350 bar. Tank pressure is 35 bar with the Y-port plugged and internal drain, or up to 350 bar with the plug removed and an external drain connected.