Brand:

Parker D3W004KNJWTI4N NG10 Valve, Start-Position Monitored

Description

D3W004KNJWTI4N NG10 valve for press-type start-position monitoring

The Parker D3W004KNJWTI4N is a single-solenoid, two-position NG10 (CETOP 05 / NFPA D05) directional valve with an inductive sensor that watches the spool at its rest position. Two letters in the part number make it a specific configuration: T removes the manual override, and I4 selects start-position monitoring on the A side. The catalogue states that hydraulic presses under DIN EN ISO 16092-3 require solenoid option T together with the start-position accessory I4 or I5, so this combination is the one the series offers for that duty. Seven Star LLC supplies the D3W004KNJWTI4N in Oman and the GCC.

How the code D3W004KNJWTI4N breaks down

D3W is the directional valve with NG10 interface and wet-pin solenoid. The digits 004 are the spool type. The letter K gives two positions, spring offset in position 0, operated in position b, so the solenoid sits on the b side. N is NBR seals, J is 24 V DC, and W is the EN 175301-803 solenoid connector without plug. T means no manual override, I4 means start position monitored on side A, and the closing N is the CE-coded field. The catalogue states that I1 and I4 apply to spool positions K, M and H, where the solenoid is on the b-side and the sensor sits on the opposite end.

D3W004KNJWTI4N technical specifications

Parameter Specification
Manufacturer / part number Parker D3W004KNJWTI4N
Series D3W directional spool valve with inductive position control
Size / interface NG10 / CETOP 05 / NFPA D05; DIN 24340 A10, ISO 4401, CETOP RP 121-H
Spool / position 004 / K: two positions, spring offset in position 0, operated in position b
Position monitoring I4: start position monitored on side A
Manual override None (option T)
Maximum pressure P, A, B: 350 bar; T: 210 bar
Maximum flow 150 l/min (see shift limits)
Solenoid 24 V DC (code J), 1.5 A hold, 36 W
Seals / fluid NBR; hydraulic oil to DIN 51524
Temperature Fluid −20 to +70 °C; ambient −20 to +60 °C
Cleanliness ISO 4406 18/16/13
Switching frequency Up to 10,000 per hour; 100 % ED
Sensor 24 V DC ±20 %, M12x1, open-collector outputs, 250 mA per channel
Protection class / weight IP65 / 5.2 kg

Flow paths of spool 004 in the D3W004KNJWTI4N

The performance-curve table of the catalogue assigns curves for spool 004 in each position: in position b P to A and B to T are connected, in position a P to B and A to T, and in the centre or rest position A to T and B to T are listed while no P connection appears. On the valve with the K position, only position 0 and position b are used. At rest the two actuator lines therefore drain to tank, and energising the solenoid sends pump flow to port A while port B returns to tank. Maximum flow is 150 l/min, but the shift-limit chart gives spool 004 its own limit curve and the practical flow at 350 bar is lower.

Why no manual override matters

A manual override lets someone move the spool with a pin, which bypasses the controller and the position monitoring. For safety applications such as presses, the standard asks that this is not possible, so the T option leaves the end of the solenoid without an override pin. For commissioning you must then energise the solenoid electrically; plan the test circuit accordingly. The sensor works with the spool at rest: when the valve is de-energised, the inductive switch signals as the spool leaves the spring offset position, below 15 % of the stroke. It is a monitoring function and not by itself a safety rating, so the machine builder still has to perform the risk assessment.

Electrical data for the D3W004KNJWTI4N

The solenoid draws 1.5 A at 24 V DC (36 W), is rated for 100 % duty and 10,000 switching cycles per hour, and its coil can reach 150 °C. The sensor needs 24 V DC with ±20 % tolerance and ripple up to 10 %. Outputs are open collector, 250 mA per channel with ohmic load, and the switching hysteresis is below 0.06 mm. The sensor connection is M12x1 per IEC 61076-2-101 and the plug is ordered separately. For the double-solenoid start-position versions the catalogue recommends a straight M12 plug because a defined position cannot be guaranteed with an angled one, so a straight plug is a sensible choice here as well. Keep the sensor cable shielded and at least 0.1 m from AC solenoids.

Related parts to D3W004KNJWTI4N

The D3W Inductive Position Control family covers other spools and position styles such as E, F, M, B and H for single-solenoid valves and C and D for double-solenoid valves with their own start and end position codes (I1 to I6). A sibling with the monitor on side B and the manual override kept is the D3W020BNJWI5N. If position monitoring is not needed, the plain D3W series has the same hydraulic data. A smaller alternative at NG06 is the D1VW series with no position control.

Selection and ordering checklist for D3W004KNJWTI4N

  • Check the applicable machine standard and whether a no-override (T) valve is required.
  • Confirm the spool function: here, drain of A and B at rest, A pressurised when the solenoid is on.
  • Match monitored side to the solenoid side: I4 for K, M and H styles.
  • Voltage and seals as per the plant (J and N here).
  • Plan the two connectors: solenoid plug and M12x1 sensor plug.
  • Check flow and pressure against shift limits.

Installation and testing of the D3W004KNJWTI4N

Install on a flat NG10 interface with 4 screws in an even sequence, on a surface free from burrs. Wire the solenoid with 3 x 1.5 mm² cable and a PE connection. Connect the sensor with screened cable and a female M12 plug, check the signal polarity against the pin table (pin 1 supply, pin 3 0 V, pin 2 output B and pin 4 output A for the single-solenoid valve), and test that the output changes state when the solenoid is energised and the spool leaves the rest position. The sensor adjustment is sealed at the factory and must not be altered.

Applications in Oman and the GCC

The D3W004KNJWTI4N is for hydraulic presses, shears, bending and forming machines, tooling stations and lifting frames where the control system must check a safe rest state before it enables a motion. In Oman these are found in steel fabrication, pipe and tank workshops and in plants that run older presses being upgraded. Use screened cabling and shaded cabinets, because heat and electrical noise can disturb sensor signals.

Information to send with an RFQ for D3W004KNJWTI4N

  • Part number D3W004KNJWTI4N and quantity.
  • Machine type and the safety standard to be met.
  • Pressure, flow and oil type.
  • Required plugs for solenoid and sensor.
  • Delivery destination.

Documents and quotation

The Parker D3W Inductive Position Control catalogue with the ordering code, sensor definitions and dimensions is attached on this page.

Seven Star LLC supplies Parker hydraulic valves in Oman and the GCC. Send the part number D3W004KNJWTI4N with your quantity and we will confirm availability and send a quotation.

Other Models in the Parker D3w Ng10 Range

Seven Star LLC supplies models from the Parker D3w Ng10 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Parker D3W020BNJWI5N NG10 Solenoid Valve, Position MonitoredHydraulic Valves & ComponentsView details
Parker D3W004KNJWTI4N NG10 Valve, Start-Position MonitoredHydraulic Valves & ComponentsYou are viewing this model
Datasheets & Documents
  • PDF Catalog Parker D3W Inductive Position Control Catalogue Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker D3W004KNJWTI4N NG10 Valve, Start-Position

Answers from our engineering team on installation, compatibility and integration.

01What do T and I4 mean in D3W004KNJWTI4N?
T means no manual override on the solenoid, and I4 is inductive start-position monitoring on side A. The catalogue requires T with I4 or I5 for presses under DIN EN ISO 16092-3.
02Which solenoid side does the sensor sit on?
The sensor is opposite the solenoid on a direct operated valve. With the K spool position the solenoid is on the b side, so the sensor monitors the A side, which is the I4 code.
03What does spool 004 do at rest?
In the rest position the catalogue curve table lists A to T and B to T, with no P connection, so both actuator ports drain to tank.
04What voltage does the D3W004KNJWTI4N need?
The solenoid is 24 V DC (code J) at 1.5 A and 36 W. The position sensor is supplied separately with 24 V DC plus or minus 20 % via M12x1.
05Are plugs included?
No. The solenoid connector is supplied without plug, and the M12x1 sensor plug has to be ordered separately, according to the catalogue notes.