Brand:

Parker D3W020BNJWI5N NG10 Solenoid Valve, Position Monitored

Description

D3W020BNJWI5N NG10 solenoid valve with inductive position control

The Parker D3W020BNJWI5N is a direct operated, two-position solenoid directional valve in the NG10 (CETOP 05 / NFPA D05) size that carries an inductive sensor on the spool. The sensor tells the controller where the spool is: this valve reports the start position on the B side, which means the machine logic can verify that the valve is in its spring offset position before it allows a dangerous movement. The D3W Inductive Position Control series is typically used in safety-relevant applications, and the spring offset position is the fail-safe position during a power failure. Seven Star LLC supplies the D3W020BNJWI5N in Oman and the GCC.

Decoding D3W020BNJWI5N

D3W is a directional valve (D), NG10 (3), with wet-pin solenoid (W). The three digits 020 give the spool type, and B is the spool position: two positions, spring offset in position b, operated in position a. N stands for NBR seals, J for 24 V DC, and W for the EN 175301-803 solenoid connector without plug. The solenoid option field is left empty, so the standard manual override is fitted. I5 selects inductive position control that monitors the start position on side B, and the final N completes the inductive position control field, which the catalogue marks as CE-coded. According to the catalogue, the sensor can only be located on the side opposite the solenoid for direct operated valves, so on this single-solenoid valve it sits at the spring end.

D3W020BNJWI5N technical specifications

Parameter Specification
Manufacturer / part number Parker D3W020BNJWI5N
Series D3W directional spool valve with inductive position control
Size / interface NG10 / CETOP 05 / NFPA D05; DIN 24340 A10, ISO 4401, CETOP RP 121-H
Spool / position 020 / B: two positions, spring offset in position b, operated in position a
Position monitoring I5: start position monitored on side B
Maximum pressure P, A, B: 350 bar; T: 210 bar
Maximum flow 150 l/min (see shift limits)
Leakage at 50 bar Up to 20 ml/min per flow path, depending on spool
Step response at 95 % Energise 105 ms; de-energise 85 ms
Solenoid 24 V DC (code J), 1.5 A hold, 36 W; standard manual override
Seals / fluid NBR; hydraulic oil to DIN 51524, 2.8 to 400 mm²/s
Temperature Fluid −20 to +70 °C; ambient −20 to +60 °C
Cleanliness ISO 4406 18/16/13
Duty / switching frequency 100 % ED; up to 10,000 switches per hour
Position sensor supply 24 V DC ±20 %, M12x1 connection, open-collector outputs, 250 mA per channel
Protection class / weight IP65 / 5.2 kg

What start-position monitoring means

In the catalogue definition, start position monitored means the valve is de-energised and the inductive switch gives a signal at the moment the spool leaves the spring offset position, that is below 15 % of the spool stroke. At that switching point the spool is still within the closed position, so only the flow paths of the offset position are available. The controller can therefore confirm that the spool is at rest, and detect a stuck spool or a valve that has shifted unintentionally. End position monitoring, by contrast, signals before the end of travel is reached, above 85 % of the stroke. The D3W020BNJWI5N uses the first approach.

The outputs are open-collector, 24 V based, with Out B normally open and Out A normally closed on the M12 pin assignment shown for single-solenoid valves, 250 mA ohmic per channel and a switching hysteresis below 0.06 mm. The adjustment is factory set and sealed, so the sensor can only be replaced or repaired by the manufacturer.

Safety context for the D3W020BNJWI5N

The catalogue points to a position paper on the machinery directive for detailed safety information. For hydraulic presses under EN ISO 16092-3, the catalogue notes that the solenoid option T (without manual override) and the start-position accessory I4 or I5 are required. The D3W020BNJWI5N has no T option, so check that requirement before applying this exact part number to a press: a version with a T code is a different part number. Whatever the machine, the valve is one element of a safety function, and the risk assessment and the control category remain the responsibility of the machine builder.

Electrical and hydraulic data in practice

The solenoid draws 1.5 A at 24 V DC (36 W) and may be switched up to 10,000 times per hour. It is rated for continuous duty, but coil temperature can reach 150 °C, so protect it from contact. The step response is 105 ms to energise and 85 ms to de-energise at 95 % of the stroke. Maximum flow of 150 l/min is limited by shift-limit curves: for any combination of pressure and flow beyond the curve the spool may fail to move. Leakage on each flow path may reach 20 ml/min at 50 bar, which matters for hold circuits that must not creep. Use clean oil to ISO 4406 18/16/13.

Related parts to D3W020BNJWI5N

The D3W Inductive Position Control family includes other codes: I1 and I4 monitor side A for valves with the solenoid on side b, I2 and I5 monitor side B, and double-solenoid valves with end-position control are also listed. The plain D3W valve without position control, for example D3W020BNJW, offers the same NG10 hydraulics. The NG06 D1VW series is the smaller alternative, and the D3DW series serves the same NG10 footprint with a different design. The M12x1 female connector is ordered separately; the catalogue gives order number 5004109 for it.

Selection and ordering checklist for D3W020BNJWI5N

  • Confirm the circuit needs a two-position spool of type 020 with the spring offset in position b.
  • Decide between start-position and end-position monitoring and which side.
  • Match solenoid voltage (K 12 V, J 24 V, U 98 V, G 205 V) and seals (N or V).
  • Check whether the machine standard requires option T (no manual override).
  • Order the solenoid plug and the M12x1 sensor plug separately.
  • Verify the flow against the shift-limit curve at your pressure.

Installation and testing of the D3W020BNJWI5N

Mount the valve on a flat NG10 interface in any orientation, horizontal preferably. Wire the solenoid with 3 x 1.5 mm² cable, up to 50 m recommended, and connect the protective conductor. Use screened cable and a female connector for the sensor, since the EMC data is only guaranteed in that case, and keep it at least 0.1 m away from the nearest AC solenoid. During commissioning, test the sensor logic by energising the solenoid and watching the output change as the spool leaves the start position. Do not tamper with the sensor adjustment or its seal.

Applications in Oman and the GCC

Valves with monitored spools suit hydraulic presses, shears, cutting and forming machinery, lifting and tilting devices, and process skids where a controller must prove a safe state before releasing energy. For Omani industry this includes fabrication shops, heavy-equipment workshops and plant maintenance rigs. High ambient temperature, dust and long cable runs can disturb sensors, so screened cable and a clean enclosure are advisable.

Information to send with an RFQ for D3W020BNJWI5N

  • Part number D3W020BNJWI5N and quantity.
  • Machine type and any safety standard to be met.
  • Pressure, flow and fluid data.
  • Required connectors for solenoid and sensor.
  • Delivery destination.

Documents and quotation

The Parker D3W Inductive Position Control catalogue with the ordering code, sensor data and dimensions is attached on this page.

Seven Star LLC supplies Parker hydraulic valves in Oman and the GCC. Send the part number D3W020BNJWI5N with your quantity and we will confirm availability and quote.

Other Models in the Parker D3w Ng10 Range

Seven Star LLC supplies models from the Parker D3w Ng10 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Parker D3W020BNJWI5N NG10 Solenoid Valve, Position MonitoredHydraulic Valves & ComponentsYou are viewing this model
Parker D3W004KNJWTI4N NG10 Valve, Start-Position MonitoredHydraulic Valves & ComponentsView details
Datasheets & Documents
  • PDF Catalog Parker D3W Inductive Position Control Catalogue Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker D3W020BNJWI5N NG10 Solenoid Valve, Position

Answers from our engineering team on installation, compatibility and integration.

01What does I5 mean in D3W020BNJWI5N?
I5 is the inductive position control code that monitors the start position on side B. The sensor signals when the spool leaves the spring offset position.
02Does the valve have a manual override?
Yes. The solenoid option field is empty in the part number, which means the standard manual override is fitted. Option T would remove it and is a different code.
03What voltage does the D3W020BNJWI5N use?
It has a 24 V DC solenoid (code J) drawing 1.5 A and 36 W. The position sensor is supplied separately with 24 V DC plus or minus 20 % through an M12x1 connection.
04What are the pressure and flow limits?
Ports P, A and B are rated to 350 bar and port T to 210 bar. Maximum flow is 150 l/min, subject to the shift-limit curve for the spool.
05Is the sensor plug included?
No. The catalogue says the M12x1 female connector must be ordered separately, with order number 5004109, and the solenoid connector is also supplied without plug.