Brand: Parker
Parker D3FPE02YC9NB70 NG10 Proportional Servo Valve 100 l/min
Description
D3FPE02YC9NB70 NG10 direct operated proportional valve
The Parker D3FPE02YC9NB70 is the NG10 (CETOP 05 / NFPA D05) member of the DFplus proportional range. Where the D1FP in NG06 handles up to about 90 l/min, the D3FP is sized for higher flow, with an overlap spool rated at 100 l/min per control edge at a 35 bar pressure drop and a maximum flow of 150 l/min. A VCD actuator drives the spool directly, the onboard electronics close the spool-position loop, and a ±10 V command sets the opening. It is a choice for hydraulic axes that need fast, repeatable motion without a pilot stage. Seven Star LLC supplies the D3FPE02YC9NB70 in Oman and the GCC.
Reading the code D3FPE02YC9NB70
Using the D3FP ordering table: D3FP is the series (D directional valve, 3 for NG10, F proportional, P VCD actuator). E02Y is the spool. E02 is an overlap spool and Y is the larger flow size, 100 l/min per metering edge at 35 bar. The following C is the power-down position: centre position, which the catalogue allows only for overlapped spools. The 9 means a plugged Y-port, N is NBR seals, B is the 0 to ±10 V command, 7 is the 6 + PE + enable electrical option and the final 0 is the spool/sleeve design. A valve with the same spool but a different position code, such as A or B, would open about 10 % at power-down and is only offered with zerolap and underlap spools, so the C here is tied to the overlap spool.
D3FPE02YC9NB70 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker D3FPE02YC9NB70 |
| Series | D3FP direct operated servo proportional directional valve, VCD actuator |
| Size / interface | NG10 / CETOP 05 / NFPA D05; DIN 24340, ISO 4401, CETOP RP121 |
| Spool | E02Y: overlap spool, 100 l/min nominal at 35 bar per metering edge |
| Spool position on power-down | C: centre position (overlapped spools only) |
| Maximum flow | 150 l/min |
| Maximum pressure | P, A, B: 350 bar; T: 35 bar internal drain, 250 bar external drain; Y: 35 bar |
| Step response (100 % step) | < 6 ms |
| Frequency response | 200 Hz at ±5 % signal (−3 dB, −90°) |
| Hysteresis / sensitivity | < 0.05 % / < 0.03 % |
| Leakage at 100 bar | < 100 ml/min (overlap spool) |
| Command signal | Code B: 0 to ±10 V |
| Electronics / connection | Onboard; code 7: 6 + PE + enable to EN 175201-804 |
| Supply | 24 V DC nominal (22 to 30 V), 3.5 A max, 4 A medium-lag fuse |
| Seals / fluid | NBR; hydraulic oil to DIN 51524 to 535 |
| Fluid temperature / ambient | −25 to +60 °C (NBR) / −20 to +60 °C |
| Cleanliness / viscosity | ISO 4406 18/16/13 / 20 to 400 mm²/s |
| Protection class / weight | IP65 / 6.5 kg |
Behaviour of the D3FPE02YC9NB70 in a control loop
The overlap spool closes all control edges at zero command, so the leakage is low: the catalogue lists below 100 ml/min at 100 bar for this valve, against below 400 ml/min for zerolap spools. The cost of overlap is a dead band around null, so these spools suit applications that hold a load or pressure and do not require infinite resolution at null. The step response is below 6 ms and the frequency response 200 Hz at a small signal, which are slower than the NG06 valve because the spool is larger but still well within the range of servo-valve performance.
With the centre power-down position, a supply failure or an enable removal brings the spool to its mid position, and the overlap closes the ports. As the catalogue explains for all DFplus valves, this behaviour cannot be guaranteed with contaminated oil or with a single flow path at a drop above 120 bar.
Wiring and enable function of the D3FPE02YC9NB70
The code 7 option provides a six-pin connection plus PE and an enable input. The enable follows EN 61131-2 type 3: low −3 to +5 V, high 11 to 30 V with 3 mA input current. The catalogue recommends a 7 x 1.0 mm² (AWG 16) braid-shielded cable up to 50 m for the six-pin connection, a 24 V supply of 22 to 30 V with ripple below 5 %, a 4 A medium-lag fuse and a maximum current of 3.5 A. The command input has 100 kOhm impedance for voltage signals, and the diagnostic output reads ±10 V or 4 to 20 mA. The connector must be ordered separately for this series. An IO-Link Class A interface and an NFC interface are built in for parameterisation, with an RGB status LED for a quick visual check.
Where the D3FPE02YC9NB70 sits in the Parker range
The same spool-code logic applies across the DFplus series. D3FP spools exist in E50 (zerolap), E55 (underlap), E01 and E02 (overlap) and B-types with a 2:1 flow ratio, in sizes P (50 l/min) and Y (100 l/min). The smaller NG06 relative, the D1FPE55HA9NB50, offers 25 l/min on its underlap spool. For larger flows, the catalogue range continues with pilot operated servo proportional valves such as the D31FP to D111FP series. Pairing with an E-module or a servo drive builds a closed-loop axis.
Selection and ordering checklist for D3FPE02YC9NB70
- Nominal flow per edge at the actual pressure drop, using the square-root relationship to scale from 35 bar.
- Spool leakage and dead band acceptable for the load-holding duty.
- Power-down position consistent with the machine safe state.
- Tank pressure: with the Y-port plug in, tank is limited to 35 bar; for up to 250 bar remove the plug and pipe the Y-port to tank.
- Command signal, enable logic and cable length match the controller.
- Fluid, viscosity and cleanliness within the stated limits.
Installation and commissioning of the D3FPE02YC9NB70
Mount on a flat NG10 interface and fit the O-rings supplied. Because the valve weighs 6.5 kg, support the manifold properly, and keep the electronics area free for connectors and airflow. Flush the system, check the oil is at ISO 4406 18/16/13 or cleaner. Apply 24 V, set the enable signal, then step through small command values while observing the pressure and axis movement. If the axis hunts, review the controller gains and supply quality first. Keep spares of NBR seals and the matching electrical connector on hand.
Typical applications in Oman and the GCC
NG10 proportional valves of this kind appear in presses, test stands, rolling and forming lines, large injection moulding machines, and in turbine and rotating machinery test rigs. In Omani industry they are likely to be found in heavy fabrication, metals processing, and plants that have hydraulic position or force loops. Keep the electronics out of direct sun and respect the 60 °C ambient limit; cabinet cooling is advisable in summer.
Information to send with an RFQ for D3FPE02YC9NB70
- Part number D3FPE02YC9NB70 and quantity.
- Controller type, command and enable wiring.
- Pressure, tank pressure and flow of the axis.
- Fluid type and cleanliness level.
- Required connectors and cables.
- Delivery destination.
Documents and quotation
The Parker D3FP catalogue with the ordering table, technical data and characteristic curves is attached on this page.
Seven Star LLC supplies Parker hydraulic valves in Oman and the GCC. Send us the part number D3FPE02YC9NB70 and your quantity for availability and a quotation.
Other Models in the Parker D1fp Ng06 Range
Seven Star LLC supplies models from the Parker D1fp Ng06 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Parker D1FPE55HA9NB50 NG06 Proportional Servo Valve 25 l/min | Hydraulic Valves & Components | View details |
| Parker D3FPE02YC9NB70 NG10 Proportional Servo Valve 100 l/min | Hydraulic Valves & Components | You are viewing this model |
Datasheets & Documents
- Catalog Parker D3FP Proportional Valve Catalogue Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker D3FPE02YC9NB70 NG10 Proportional Servo Valve
Answers from our engineering team on installation, compatibility and integration.
01What flow does the D3FPE02YC9NB70 give?
The Y in E02Y denotes 100 l/min per metering edge at a 35 bar pressure drop. The maximum flow of the D3FP is 150 l/min according to the catalogue.
02What does the C in the part number mean?
It is the spool position at power-down. Code C means the centre position and is available only with overlapped spools such as the E02Y.
03How does the D3FP compare with the D1FP?
The D3FP is NG10 (CETOP 05) with a step response below 6 ms and 200 Hz frequency response, while the NG06 D1FP reaches below 3.5 ms and 350 Hz with less flow.
04What does electronics code 7 offer on the D3FPE02YC9NB70?
Code 7 gives a 6 + PE connection with an enable input. The enable signal follows EN 61131-2 type 3, with high from 11 to 30 V and low from minus 3 to plus 5 V.
05What tank pressure is allowed?
With internal drain the tank port is limited to 35 bar. With the Y-port plug removed and an external drain connected the catalogue allows up to 250 bar on the tank port.


















Reviews