Brand:

Parker D1VW001CNJW NG06 Solenoid Directional Valve 24 V DC

Description

D1VW001CNJW NG06 directional control valve with two 24 V solenoids

The Parker D1VW001CNJW is a direct operated, three-position solenoid directional valve in the NG06 (CETOP 03 / NFPA D03) size. It is one member of the D1VW series, which Parker rates for up to 350 bar on the P, A and B ports and up to 80 l/min of flow with a low pressure drop. The valve is a sandwich of a cast body and two wet-pin solenoids threaded onto armature tubes, so it can be bolted straight onto a standard NG06 subplate or manifold. This page covers the 24 V DC version with nitrile seals and spool type 001. Seven Star LLC supplies the D1VW001CNJW in Oman and the GCC.

How the part number D1VW001CNJW is built

The D1VW ordering code is read from left to right. D means directional control valve, 1 is the NG06 size, V marks the 3-chamber valve body and W the wet-pin solenoid on a threaded-in tube. The three digits 001 select the spool type, which fixes the flow paths in each position. The next letter, C, is the spool position code: three positions, spring offset into position 0, solenoid operation into position a or b. N stands for NBR seals, J for the 24 V DC solenoid, and the last letter W for the EN 175301-803 connector supplied without a plug. The solenoid option field is empty here, so the valve has the standard manual override at each solenoid.

D1VW001CNJW technical specifications

Parameter Specification
Manufacturer / part number Parker D1VW001CNJW
Spool type / position 001 / C: three positions, spring offset in position 0, operated in position a or b
Seals NBR (code N)
Solenoid voltage 24 V DC (code J), 1.29 A hold current, 31 W
Solenoid option Standard with manual override
Weight 2.1 kg (two solenoids)
Valve family Directional spool valve, series D1VW, 3-chamber body with wet-pin threaded-in-tube solenoids
Actuation Solenoid, direct operated
Nominal size / interface DIN NG06 / CETOP 03 / NFPA D03; DIN 24340 A6, ISO 4401, CETOP RP 121-H
Mounting Subplate, any orientation, horizontal preferred
Maximum operating pressure P, A, B: 350 bar; T: 210 bar (DC solenoids)
Maximum flow 80 l/min (limited by the shift-limit curve of the chosen spool)
Fluid Mineral hydraulic oil to DIN 51524; viscosity 2.8 to 400 mm²/s, 30 to 80 recommended
Cleanliness ISO 4406 18/16/13
Ambient temperature −25 to +60 °C
Duty ratio / switching frequency 100 % ED; up to 15,000 switches per hour
Protection class IP65 with the plug-in connector correctly fitted
Electrical connection Connector to EN 175301-803 (plug ordered separately)

How the D1VW001CNJW switches

With both coils de-energised the centring springs hold the spool in position 0. Energising the solenoid at one end pushes the spool to position a or b, and the oil path between P, A, B and T changes accordingly. The catalogue flow-curve table for spool 001 lists pressure-drop data for the energised positions only: P to A and B to T in position b, and P to B and A to T in position a. No centre-position flow paths are listed for this spool. The valve is a standard on/off type, so the spool travels fully, and the response is quoted as 45 to 60 ms to energise and 20 to 30 ms to de-energise for a standard DC solenoid. A rectifier plug would lengthen both figures, and AC solenoids are faster but are a different voltage code.

Shift limits matter on the D1VW001CNJW. The maximum flow of 80 l/min is a ceiling, not a guaranteed figure at every pressure, because the spool must be able to overcome flow forces at the moment it moves. The catalogue gives shift-limit curves per spool type measured with HLP46 oil at 50 °C and 90 % of nominal voltage, and a plug-in orifice can be fitted in the P port when peak flow could exceed the limit.

Where the D1VW001CNJW fits in a hydraulic system

An NG06 valve like the D1VW001CNJW typically controls a small cylinder, a clamp, a swivel or a hydraulic motor from a power pack or manifold block. It is often stacked with Z1 sandwich valves such as pressure reducing, check or flow control plates between the valve and the subplate. The same NG06 footprint accepts siblings with other spools, so spool 002, 004 or 006 variants of the D1VW can replace this one when the circuit needs a different centre position. For larger flows the next step is the NG10 D3W family, and for proportional control the D1FP direct operated proportional valve shares the NG06 interface. The same valve with FPM seals is the D1VW001CVJW, listed separately.

Selection and ordering checklist for D1VW001CNJW

  • Confirm the subplate or manifold is NG06 / CETOP 03 with the A6 hole pattern.
  • Check the symbol of spool 001 against the circuit drawing, especially the centre-position behaviour.
  • Match the supply voltage: 24 V DC is code J; 12 V DC (K), 98 V DC (U), 205 V DC (G), 110/120 V AC (Y) and 230/240 V AC (T) are separate part numbers.
  • Choose NBR (N) for mineral oil at up to +70 °C fluid temperature or FPM (V) for higher temperature or synthetic fluids.
  • Order the EN 175301-803 connectors and the NG06 mounting bolts separately; the catalogue lists the kit with four M5 x 30 screws tightened to 7.6 Nm.
  • Verify the maximum flow at your working pressure against the shift-limit curve.

Installation, commissioning and maintenance

Fit the D1VW001CNJW on a clean, flat subplate with the O-rings in place and tighten the four M5 x 30 socket screws (ISO 4762, grade 12.9) evenly to 7.6 Nm ± 15 %. Leave at least 15 mm beside the connector so the plug can be removed, and tighten the M3 plug screw to 0.5 to 0.6 Nm. Use a 3 x 1.5 mm² cable, up to 50 m long as recommended, with the protective conductor connected. The coil can reach 150 °C at continuous duty, so keep flammable material and cable insulation away and never touch it during operation.

Keep the oil at ISO 4406 18/16/13 or cleaner for the D1VW001CNJW. Most field failures of directional valves trace back to contamination holding the spool, or to a worn solenoid after overheating. The manual override on the D1VW001CNJW lets you shift the spool without electrical power during commissioning, which is useful for checking cylinder directions before enabling the controller. Spare seal kits (SK-D1VW-N-91 for NBR, SK-D1VW-V-91 for FPM) exist for both NBR and FPM versions, and a coil can be replaced without opening the hydraulic circuit because the armature tube stays sealed.

Typical applications in Oman and the GCC

Valves such as the D1VW001CNJW are common on small hydraulic power units in workshops, test rigs and process skids. In Oman and the wider Gulf region they show up on valve actuator power packs in oil and gas facilities, on hydraulic gates and tilting systems at desalination plants, on lifting and clamping tools in fabrication yards, and on mobile service equipment. High ambient heat and dust make clean oil and a well-sealed solenoid connector important, and the 60 °C ambient limit should be checked against enclosure temperatures in direct sun.

D1VW code options at a glance

Option Codes in the catalogue
Solenoid voltage K 12 V DC, J 24 V DC, U 98 V DC, G 205 V DC, Y 110 V 50 Hz / 120 V 60 Hz, T 230 V 50 Hz / 240 V 60 Hz
Seals N NBR, V FPM
Spool position C, E, F, K, M (3-position and spring offset styles), B, D, H for two-position styles
Solenoid options Omit for standard override, T without manual override, S2 and S3 soft-shift orifices (DC only), 4N lockable manual override (DC only)
Current at 24 V 1.29 A hold, 31 W
Weight 1.5 kg with one solenoid, 2.1 kg with two

The code set shows how many different valves share the NG06 footprint. The D1VW001CNJW is the 24 V DC, NBR, spool 001 configuration with the standard override.

Information to send with an RFQ for D1VW001CNJW

  • Full part number and quantity.
  • Fluid type, working temperature and maximum flow and pressure.
  • Solenoid voltage and any need for a lockable override or soft shift.
  • Required plugs, subplates or mounting bolts.
  • Delivery location in Oman or elsewhere in the GCC.

Documents and quotation

The Parker D1VW catalogue with the ordering code, flow curves and dimensions is attached on this page. It is the best reference for checking spool symbols and shift limits before you order.

Seven Star LLC supplies Parker hydraulic valves in Oman and the GCC. Send us the part number D1VW001CNJW with your quantity and we will reply with availability and a quotation.

Other Models in the Parker D1vw Ng06 Range

Seven Star LLC supplies models from the Parker D1vw Ng06 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Parker D1VW001CNJW NG06 Solenoid Directional Valve 24 V DCHydraulic Valves & ComponentsYou are viewing this model
Parker D1VW001CVJW NG06 Solenoid Valve, FPM Seals, 24 V DCHydraulic Valves & ComponentsView details
Parker D1VW004CNJW NG06 Solenoid Valve, Tank-Open CentreHydraulic Valves & ComponentsView details
Datasheets & Documents
  • PDF Catalog Parker D1VW Directional Control Valve Catalogue Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker D1VW001CNJW NG06 Solenoid Directional Valve

Answers from our engineering team on installation, compatibility and integration.

01What size is the D1VW001CNJW?
It is an NG06 (CETOP 03 / NFPA D03) valve with the DIN 24340 A6 / ISO 4401 mounting interface, so it fits standard NG06 subplates and manifolds.
02What voltage does the D1VW001CNJW use?
The letter J in the part number means a 24 V DC solenoid. The catalogue lists 1.29 A hold current and 31 W power consumption per solenoid at this voltage.
03What are the pressure and flow limits?
The P, A and B ports are rated to 350 bar and the tank port to 210 bar for DC solenoids. Maximum flow is 80 l/min, subject to the shift-limit curve for the spool type.
04Which seals does the D1VW001CNJW have?
The N in the part number means NBR seals. The same valve with FPM seals carries a V in that position, as in D1VW001CVJW, for higher fluid temperatures or specific fluids.
05Does the valve come with the electrical plug?
No. The W in the code means the EN 175301-803 connection without plug, so the connectors must be ordered separately.