- Automation & ControlView all 3,044 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Magnetrol
Magnetrol Echotel 941 Ultrasonic Level Switch, mA Output
Description
Overview
Magnetrol Echotel 941 is a compact contact ultrasonic level switch that reports a wet or dry transducer gap through a current shift on its two-wire signal line. It belongs to the Echotel 940 and 941 series built by Magnetrol, and the 941 is the member with the mA output instead of a relay. A 316 stainless steel tip-sensitive transducer sits at the end of a slim barrel, while the pulsed electronics are fully encapsulated just above the process fitting, so the whole unit is little more than a stainless probe with three flying leads. Seven Star LLC is an independent supplier serving Oman and the GCC.
Where a conventional float or a tuning fork is too bulky, too fussy about viscosity, or too sensitive to foam, a probe of this type is often the cleaner answer. The sensing principle needs no calibration, no set point adjustment and no moving parts, which is why skid builders and maintenance teams like it for point-level duty on pumps, small tanks and fill lines.
How the Echotel 941 detects liquid
The transducer contains a pair of piezoelectric ceramic crystals encapsulated in epoxy at the tip. One crystal is the transmitter and is driven by the electronics; the other is the receiver. When liquid fills the small gap between them, high frequency sound crosses easily and the receiver sees a strong signal. When the gap is dry or contains only foam or vapor, the signal is attenuated and the receiver sees almost nothing. The electronics evaluate that difference and shift the loop current.
With the 941 the shift is deliberately simple: the dry gap state is 8 mA with a tolerance of plus or minus 1 mA, and the wet gap state is 16 mA with the same tolerance. A PLC analog input, a two-wire barrier or a current-sensing relay can read those two plateaus without any scaling effort. Because the gap is open at the tip, viscous liquids drain from it and turbulent foam is shed, which protects against false wet readings.
Key features of Magnetrol Echotel 941
- Pulsed electronics with strong immunity to electromagnetic noise and difficult process conditions
- Tip-sensitive 316 stainless steel transducer that drains viscous liquids and sheds foam
- Current shift output of 8 mA dry and 16 mA wet, each with plus or minus 1 mA
- Suitable for SIL 1 loops according to the manufacturer data
- 12 to 35 VDC supply with consumption of less than 1 watt
- Response time of about one half second and repeatability of 0.078 inch (2 millimeters)
- Factory sealed construction with 18 inch (457 mm) flying leads of 18 AWG wire
- Choice of NPT, BSP, ASME flange and Tri-Clamp process connections
Magnetrol Echotel 941 technical specifications
| Model | 941, compact ultrasonic level switch with current shift output |
| Power supply | 12 to 35 VDC |
| Power consumption | Less than 1 watt |
| Signal output | Dry gap 8 mA (plus or minus 1 mA); wet gap 16 mA (plus or minus 1 mA) |
| Wetted transducer | 316 stainless steel, tip sensitive |
| Cabling | 18 inch (457 mm) flying leads, 18 AWG |
| Repeatability | 0.078 inch (2 millimeters) |
| Response time | About 1/2 second typical |
| Ambient temperature | -40 to +185 F (-40 to +85 C) |
| Process temperature | -40 to +185 F (-40 to +85 C) |
| Maximum pressure | 2000 psig (138 bar) for 1 inch NPT and 2 inch BSP transducers; 1500 psig (103 bar) for longer transducers |
| Shock | ANSI/ISA-S71.03 Class SA1 |
| Vibration | ANSI/ISA-S71.03 Class VC2 |
| Agency approval (941) | FM intrinsically safe, Class I Div 1 Groups A to D, Class II Div 1 Groups E to G, Class III, Type 4X, IP 66, T4 |
| Actuation length | 1 to 100 inches or 3 to 250 centimeters |
Reading the Echotel 941 order code
The datasheet builds the code from ten positions. The first three digits are the model, 941. The fourth selects the approval: 1 for FM intrinsically safe and non-incendive, or 2 for the same approval with ASME B31.3 construction and a CRN available. Digits five and six give the process connection: 11 is three-quarter inch NPT, 22 is 1 inch BSP, 23 is a 1 inch 150 pound raised-face flange, 33 is a one and a half inch 150 pound flange, 43 is a 2 inch 150 pound flange, 3T is a one and a half inch Tri-Clamp 16 AMP fitting and 4T is a 2 inch Tri-Clamp. Digit seven is the unit letter, E for inches or M for centimeters, and digits eight to ten state the actuation length, for example 004 for 4 inches.
Every connection except the plain three-quarter inch NPT carries a minimum actuation length of 2 inches or 5 centimeters. For the exact orderable string of a replacement, confirm the full order code on the nameplate of the existing unit and quote it with your RFQ.
How Echotel 941 differs from other Echotel 940 and 941 variants
The only electrical difference inside the family is the output stage. The 940 provides an SPDT relay rated 1 amp at 30 VDC, 0.5 amp at 125 VDC and 0.5 amp at 150 VAC, and it is listed for SIL 2 loops. The 941 replaces the relay with the 8 mA and 16 mA current shift, is listed for SIL 1 loops, and is the version carrying the FM intrinsically safe approval in Class I Division 1. In the model number the 941 pairs with approval codes 1 or 2, while the 940 pairs with codes 7 or 8, which are non-incendive only.
Mechanically the two models share the same transducer, the same 0.875 inch (22 mm) barrel diameter and the same process connection list, so a 941 can be swapped for a 940 only if the control side can accept a current signal instead of a dry contact.
Typical applications in Oman and the GCC
In upstream and downstream hydrocarbon facilities Magnetrol Echotel 941 fits skid-mounted lube oil reservoirs, chemical injection tanks, drain pots and knock-out vessels where a hardwired high or low alarm must reach a safety or control system through a two-wire loop. In water and wastewater plants it covers chemical dosing tanks, sump alarms and pump dry-run protection. Utilities use it for fuel day tanks and cooling water make-up tanks, and manufacturing sites use it for coolant, hydraulic oil and cleaning solution reservoirs.
The manufacturer also notes use in the interstitial space between two tank walls for leak detection, and as a replacement for older floats, conductivity switches and tuning forks. The narrow body makes it practical in crowded Gulf skid packages.
Selection and compatibility notes
For Magnetrol Echotel 941, choose the connection to match the nozzle: threaded for small tanks, flanged for vessels with raised-face nozzles, Tri-Clamp where a sanitary fitting is expected. Remember that the process temperature range stops at +185 F (+85 C), so the 941 is not intended for hot condensate or heated bitumen lines. Pressure limits depend on length: 2000 psig for the 1 inch NPT and 2 inch BSP transducers but 1500 psig for longer ones.
The loop must supply 12 to 35 VDC. Because the output is a current shift, make sure the receiving input can distinguish 8 mA from 16 mA and that any wiring fault detection threshold is set outside that window. Where the area is classified, follow the control drawing and use an appropriate barrier.
Installation and commissioning
Mount the probe in any orientation that lets the transducer gap fill and drain naturally; the datasheet shows side, top and bottom entries. Keep the gap free of weld spatter and sealing tape. Run the flying leads to a junction box, noting that a NEMA 4 cast aluminum junction box assembly, number 052-7012-XXX, is available from the factory.
There is nothing to calibrate. After wiring, wet the tip and confirm 16 mA, then let it drain and confirm 8 mA before handing the loop to operations.
Maintenance
Inspect the tip during routine shutdowns for crystallized product, polymer film or heavy scale in the gap, and flush with a compatible solvent. Do not scrape the epoxy. Periodically proof-test the loop by raising and lowering the liquid or by immersing the tip in a sample container. Warranty terms in the datasheet cover eighteen months from factory shipment for electronic level and flow controls.
Related items you may also need: Magnetrol E4 Modulevel Displacer Level Transmitter | Magnetrol Z31-2864-002 Electronic Module for Pulsar R86 Fieldbus | Magnetrol 030-9114-001 PC Board for Thermatel TG1 Sensor Housing | All Magnetrol products.
Magnetrol Echotel 941 ordering checklist
- When the Magnetrol Echotel 941 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
- Every enquiry for the Magnetrol Echotel 941 is answered with a written confirmation of the code and expected lead time.
- Use the attached datasheet to check the Magnetrol Echotel 941 ratings, dimensions and connection details against your drawings.
- We supply the Magnetrol Echotel 941 as part of our level switches range to plants in Oman and the GCC.
- For critical duty, keeping one Magnetrol Echotel 941 as a site spare shortens downtime after a failure.
Documents and quotation
The datasheet for Magnetrol Echotel 941 is attached to this page for selection and approval review. To obtain a quotation, send an RFQ to Seven Star LLC with the model 941, the approval digit, process connection code, unit letter, actuation length and the quantity required. Supplying the nameplate code of an existing unit speeds up matching.
Datasheets & Documents
- Datasheet Magnetrol Echotel 941 Ultrasonic Level Switch, mA Output Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Echotel 941 Ultrasonic Level Switch, mA
Answers from our engineering team on installation, compatibility and integration.
01What output does the Echotel 941 give when the gap is wet or dry?
The datasheet states 16 mA plus or minus 1 mA when the gap is wet and 8 mA plus or minus 1 mA when it is dry, so one two-wire loop carries the alarm state.
02What supply voltage does Echotel 941 need?
It runs from 12 to 35 VDC and draws less than 1 watt, so it suits standard 24 VDC control panels and barrier-fed loops.
03Which temperature and pressure limits apply?
Process and ambient temperature are both -40 to +185 F (-40 to +85 C); maximum pressure is 2000 psig for 1 inch NPT or 2 inch BSP and 1500 psig for longer transducers.
04How is the actuation length specified on the Echotel 941?
Digits eight to ten give the length, 1 to 100 inches or 3 to 250 centimeters, with a unit letter E or M before it; most connections need at least 2 inches.
05Is the Echotel 941 the same as the 940?
No. The 940 has a one amp SPDT relay and SIL 2 listing, while the 941 has an 8 and 16 mA current shift output and SIL 1 listing.


















Reviews
There are no reviews yet.