Magnetrol 030-9114-001 PC Board for Thermatel TG1 Sensor Housing
Description
Magnetrol 030-9114-001: sensor housing PC board for the Thermatel TG1
Magnetrol 030-9114-001 is the printed circuit board listed as item 1 in the replacement parts drawing of the Thermatel TG1 manual BE 54-605. It lives inside the small cast housing that sits on the sensor, not in the DIN rail amplifier, and it is the electronic link between the heated tip of the sensor and the two-wire cable that runs to the panel.
The manual lists only four spares for that housing: the PC board 030-9114-001, the housing cover (004-9105-001 for aluminium, 004-9142-001 for stainless), the O-ring 012-2101-345, and the sensor, for which the manual says to consult the factory. That makes 030-9114-001 the only electronic spare for the process side, which is why instrument technicians search for it by number. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What 030-9114-001 does in the TG1 measuring chain
A thermal dispersion sensor holds a heated element above the temperature of a reference element and measures the power or temperature difference needed as the fluid carries heat away. The board in the sensor housing conditions those signals and exchanges them with the DIN rail electronics through the connecting cable, whose manual figures are 2 wire, shielded, 0.50 mm2 and from 1 m to 500 m. The manual states that the range selection is made in the probe electronics, while the alarm set point is trimmed on the DIN rail housing.
- Mounted in the sensor housing: IP 65, cast aluminium or cast stainless steel.
- Cable entry choices from the model code: M20 x 1.5 (code T) or 3/4 inch NPT (codes 2 and 6).
- Operates over an ambient range of -40 to +70 C; the ATEX conditions require that the amplifier enclosure does not exceed +70 C.
- Intrinsically safe: ATEX II 1 G EEx ia IIB T5, with certificate ISSeP00ATEX007X for the sensor and enclosure.
Technical data around 030-9114-001
| Parameter | Value |
|---|---|
| Part number | 030-9114-001 |
| Manual item | 1, PC board (sensor housing) |
| Other housing spares | Cover 004-9105-001 or 004-9142-001, O-ring 012-2101-345, sensor on request |
| Housing material | Cast aluminium or cast stainless steel |
| Ingress protection | IP 65 |
| Cable entry | M20 x 1.5, or 3/4 inch NPT |
| Housing weight (electronics only) | Aluminium 1.6 kg (3.5 lbs); stainless steel 4.0 kg (8.8 lbs) |
| Overhead clearance for the cover | 70 mm (2.75 inch) shown on the drawing |
| Housing diameter on the drawing | 118 mm (4.63 inch) |
| Special condition (ATEX) | Avoid impact or friction on the aluminium housing; keep the internal temperature at or below +70 C |
| Process sensor options | Standard TMA to TMD, high temperature TMH (up to +450 C), mini TMM, low flow body TML |
| Typical response | 1 to 10 s depending on sensor and set point |
Typical use of Magnetrol 030-9114-001 in oil and gas, utilities, water and manufacturing
Process-side electronics see heat, vibration and humidity more than a panel does. The manual limits the ambient temperature to -40 to +70 C and the humidity to 0 to 99 percent non condensing, and it recommends the heat extension (223 mm instead of 46 mm on threaded sensors) or the high temperature version when the enclosure would otherwise exceed +70 C. A board is the item to hold in stock when a sensor reads erratically but the cable and the amplifier test good.
Typical applications of the TG1 in the GCC include proving flow in seal gas and cooling lines on compressors, monitoring blower air in aeration basins, supervising gas to burners in industrial boilers, and detecting dry running in small process lines.
How 030-9114-001 differs from the other TG1 spares
| Spare | Role |
|---|---|
| 030-9114-001 | Sensor housing PC board; process side |
| 089-7905-001 | DIN rail housing with electronics; panel side, TG1 |
| 004-9105-001 | Housing cover, aluminium housing |
| 012-2101-345 | O-ring seal for the cover |
Unlike 089-7905-001, which has the relay, the mA output and the LED display, the 030-9114-001 has no user interface at all. Replacement is therefore diagnosed by comparing readings at the amplifier, with the sensor cable verified first.
Selection and compatibility for 030-9114-001
- It is listed in the TG1 manual only; do not assume it fits other Thermatel models such as TD1, TD2 or TA2.
- Check the housing digit 8 of the model code: the cover differs for aluminium and stainless, though the board is the same item in the table.
- If the nameplate shows a customer-specific X option, confirm the board before ordering.
Installation and commissioning of 030-9114-001
Remove power or confirm that the area is non hazardous, unscrew the cover, and mark every wire before disconnecting. Handle the board by the edges, protect it from static, fit it, and refit the O-ring 012-2101-345 so the IP 65 rating is kept. After closing the housing, power the loop, check that the Power LED is lit on the amplifier, and verify that the safe, approaching and alarm LEDs respond when the flow changes.
Maintenance of 030-9114-001
Inspect the O-ring, cover thread and cable gland at every service round. Moisture on the board is the usual reason for replacement, so a failed board should prompt a look at the cable entry and gland. Keep the removed board for a failure note rather than discarding it unlabeled.
For a planned shutdown, a practical kit for one TG1 sensor housing is one 030-9114-001 board, one cover O-ring 012-2101-345 and, if the cover is damaged, the correct cover for the housing material. The sensor itself is a factory item according to the manual, so a damaged tip needs a model code and the insertion length, not only a part number.
Documents and quotation
The manual BE 54-605 is attached as the datasheet for 030-9114-001 so that the drawing and the model code can be checked. To receive a quotation, send an RFQ stating part number 030-9114-001, quantity, full TG1 sensor model code and delivery location in Oman or the GCC.
Other Models in the Magnetrol Tg1 Spares Range
Seven Star LLC supplies models from the Magnetrol Tg1 Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol 089-7905-001 TG1 DIN Rail Housing and Electronics | Thermal Mass Flow Meters & Controllers | View details |
| Magnetrol 030-9114-001 PC Board for Thermatel TG1 Sensor Housing | Thermal Mass Flow Meters & Controllers | You are viewing this model |
Datasheets & Documents
- Datasheet Magnetrol 030-9114-001 PC Board for Thermatel TG1 Sensor Housing Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol 030-9114-001 PC Board for Thermatel TG1
Answers from our engineering team on installation, compatibility and integration.
01What is Magnetrol 030-9114-001?
It is the PC board listed as item 1 in the replacement parts drawing for the Thermatel TG1 sensor housing in manual BE 54-605.
02Is 030-9114-001 part of the DIN rail module?
No. The DIN rail housing with electronics is a different spare, 089-7905-001 or 089-7905-002; 030-9114-001 sits in the sensor housing.
03What other spares are listed for the TG1 sensor housing?
The manual lists the cover 004-9105-001 or 004-9142-001, the O-ring 012-2101-345 and the sensor, which is to be requested from the factory.
04What ingress protection does the sensor housing have?
The sensor housing is rated IP 65 in cast aluminium or cast stainless steel, with M20 or 3/4 inch NPT cable entries.
05Can Seven Star LLC quote 030-9114-001 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and sensor model code.


















Reviews
There are no reviews yet.