Magnetrol Z30-2086-002 Echotel 910 PC Board 24 VDC 8A DPDT

Description

Magnetrol Z30-2086-002: 24 VDC terminal-block board for the Echotel 910

Magnetrol Z30-2086-002 is the main printed circuit board of an Echotel Model 910 ultrasonic liquid level switch that runs on 24 VDC and drives an 8 A DPDT output relay. It carries terminal blocks TB4 and TB5, which is what separates it from the phono-jack boards in the Z30-2043 series, and it is item 1 of the replacement parts table in manual 51-604.

Twenty-four volts DC is the supply that most Omani control rooms and skid panels already have, so this board number turns up on pump-protection and sump-level duties more often than the mains-powered siblings. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key facts about Z30-2086-002

  • Supply: 24 VDC, tolerance plus or minus 10 percent.
  • Relay: gold flash DPDT, rated 8 A at 24 VDC (and 0.5 A at 125 VDC) in the manual specification.
  • Terminals: PC board with terminal blocks TB4 and TB5 for the transducer wires.
  • Fail-safe: field selectable through the P1 jumper, high or low.
  • No field calibration; the set point is fixed.

Technical data for Z30-2086-002

Parameter Value
Part number Z30-2086-002
Board family PC board with terminal blocks TB4 and TB5
Supply 24 VDC
Output relay 24 VDC, 8 A DPDT
Transducer tip 316 stainless steel with epoxy-encapsulated crystals
Power supply options 120 VAC or 240 VAC (+10/-15 percent), 50/60 Hz; 24 VDC (plus or minus 10 percent)
Repeatability 0.078 inch (2 mm)
Calibration None required; set point not adjustable
Operating pressure 800 psig (55 bar)
Shock / vibration ANSI/ISA-S71.03 Class SA1 / VC2

Typical use of Z30-2086-002 in oil and gas, utilities, water and manufacturing

The Model 910 is the simple, calibration-free switch for sumps, knock-out pots, lube-oil reservoirs and transfer tank high or low alarms. Because the ultrasonic gap needs liquid in it to pass 3 MHz energy, the switch needs no moving parts and works on oils, water, solvents and many slurries up to its pressure rating.

A 24 VDC board is a natural fit for PLC panels in Omani power and water stations: the same supply that feeds the PLC input card feeds the switch, and the relay contact can be wired to a lamp, an interposing relay or a PLC digital input.

How Z30-2086-002 differs from the other Echotel 910 boards

Board Variant
Z30-2086-002 24 VDC, 8 A DPDT, terminal blocks (this part)
Z30-2086-003 120 VAC, 8 A DPDT, terminal blocks
Z30-2086-004 240 VAC, 8 A DPDT, terminal blocks
Z30-2086-010 24 VDC, 5 A DPDT hermetically sealed, terminal blocks
Z30-2043-002 24 VDC, 8 A relay, phono jacks J1 and J2

So Z30-2086-002 differs from Z30-2086-010 only by its relay: a gold flash 8 A relay in place of a 5 A hermetically sealed one, which suits low-level signals better in the first case and gas-tight protection in the second. Against Z30-2043-002 the voltage and relay are the same but the transducer connection moves from terminal blocks to phono jacks.

Selection and compatibility for Z30-2086-002

  • Confirm the supply on the nameplate: 24 VDC.
  • Confirm the transducer connection: terminal blocks TB4 and TB5.
  • Select the relay wiring and fail-safe jumper after fitting, following the table in section 2.5.2.
  • The manual warns that substitution of components may impair suitability for Class I, Division 2.

Installation and commissioning of Z30-2086-002

Remove power, open the cover, and transfer the transducer leads to TB4 and TB5 one by one. Set the P1 fail-safe jumper according to the relay table: with the jumper in one position the relay is energised in wet condition, in the other position in dry condition. Run the relay wiring inside the rated contact capacity.

Test by placing the transducer gap in the liquid and watching the relay change state; then take the transducer out and see it return.

Maintenance of Z30-2086-002

The switch needs no calibration, so maintenance concentrates on a clean gap, intact O-ring (012-2101-345) and sound cover. If the switch chatters, the manual points at voltage, turbulence and aeration. Keep one spare board per supply type.

Mechanical data of the Model 910 that carries Z30-2086-002

Dimension Value
Housing diameter 4.63 inch (117 mm)
Housing section dimensions on the drawing 6.25 inch (158 mm) and 4.48 inch (113 mm)
Rotation clearance 3.44 inch (87 mm)
Overhead clearance for the cover 2.75 inch (70 mm)
Transducer diameter 0.875 inch (22 mm)
Tank connection 3/4 inch NPT, or 1 inch BSP version

Approvals and conditions of use that apply to Z30-2086-002

Manual 51-604 states the approvals of the complete Model 910. They matter for a board replacement because the certified configuration must be restored.

Item Statement
FM/FMc explosion proof FM19US0170X / FM20CA0034X, Class I Div 1 Groups B, C, D T6; Class II, III Div 1 Groups E, F, G T6; Type 4X
Non-incendive Class I Div 2 Groups A, B, C, D T5; Class II, III Div 2 Groups F and G T5
ATEX flameproof FM20ATEX0005X, II 2 G Ex db IIC T6 Gb, IP66
IECEx FMG20.0004X, Ex db IIC T6 Gb, IP66
Ambient limit -40 to +70 C; probes longer than 60 inches -20 to +70 C
Use Only with the Echotel 910 probe; keep enclosure temperature at or below 70 C to hold the T6 code

Additional characteristics of the Model 910 that the board serves are below.

Characteristic Value
Sensing principle Ultrasonic across a transducer gap, 3 MHz
Transducer tip 316 stainless steel with epoxy-encapsulated crystals
Power consumption 2.5 VA nominal
Repeatability 0.078 inch (2 mm)
Process (transducer) -40 to +250 F (-40 to +121 C)
Operating pressure 800 psig (55 bar)

Documents and quotation

The manufacturer manual 51-604 for the Echotel Model 910 is attached as the datasheet for Z30-2086-002, so the parts table, relay wiring table and specifications can be checked directly. To get a quotation, send an RFQ with part number Z30-2086-002, the quantity, the supply voltage and relay type printed on the Model 910 nameplate and the delivery location in Oman or the GCC. Quote the supply voltage and relay type with the part number, because the Model 910 boards differ in exactly those two characteristics.

Other Models in the Magnetrol 910 Range

Seven Star LLC supplies models from the Magnetrol 910 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Magnetrol Z30-2086-003 Echotel 910 Relay PC Board 120 VAC 8A DPDTLevel SwitchesView details
Magnetrol Z30-2043-003 Echotel 910 Phono Jack PC Board, 120 VACLevel SwitchesView details
Magnetrol Z30-2086-002 Echotel 910 PC Board 24 VDC 8A DPDTLevel SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Magnetrol Z30-2086-002 Echotel 910 PC Board 24 VDC 8A DPDT Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol Z30-2086-002 Echotel 910 PC Board 24 VDC

Answers from our engineering team on installation, compatibility and integration.

01What is Magnetrol Z30-2086-002?
It is the 24 VDC, 8 A DPDT relay PC board with terminal blocks TB4 and TB5 for the Echotel Model 910, item 1 in manual 51-604.
02What is the relay rating of this board?
The manual gives the gold flash DPDT relay as 8 A at 120 VAC, 8 A at 240 VAC, 8 A at 24 VDC and 0.5 A at 125 VDC.
03Does the Model 910 need calibration?
No. The manual says the switches do not require field calibration and that the set point is not adjustable.
04Which board is the phono-jack version for 24 VDC?
Z30-2043-002 is the 24 VDC board with an 8 A relay and phono jacks J1 and J2.
05Can Seven Star LLC quote Z30-2086-002?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.