Brand:

Magnetrol Z30-2086-012 Echotel 910 PC Board 240 VAC 5A Sealed Relay

Description

Why Magnetrol Z30-2086-012 is the rarest 910 mains board

Among the six terminal-block boards of the Echotel Model 910, Magnetrol Z30-2086-012 is the one that combines the 240 VAC supply with the hermetically sealed 5 A relay. It is the last item in that group in the manual and the one buyers find hardest to locate, since it is only needed by units that were ordered with the sealed relay at mains voltage.

The manual gives the combination as “240 VAC, 5A DPDT Hermetically Sealed Output Relay”. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Quick reference for Z30-2086-012

Parameter Value
Part number Z30-2086-012
Supply 240 VAC +10/-15 percent, 50/60 Hz
Relay Hermetically sealed DPDT
Contact rating 5 A at 240 VAC; also 5 A at 120 VAC and 5 A at 24 VDC in the specification
Terminals TB4 and TB5 terminal blocks
Power consumption 2.5 VA nominal
Transducer tip 316 stainless steel with epoxy-encapsulated crystals
Power consumption 2.5 VA nominal
Ambient (electronics) -40 to +158 F (-40 to +70 C)
Operating pressure 800 psig (55 bar)
Housing Aluminum sand cast, dual 3/4 inch NPT conduit entries
Process connection 3/4 inch NPT, or 1 inch BSP

Use of Z30-2086-012 in oil and gas, utilities, water and manufacturing

A mains switch with a sealed relay has a special place on installations where contact contamination is a problem: a diesel generator day tank in a dusty desert site, a condensate pot in a gas plant, or a wet well in a wastewater works. The 240 VAC supply is typically taken from the local lighting or small-power distribution, which is why this board matches many remote assets.

The relay passes low currents reliably, so it is common to wire it to a PLC digital input or a signal lamp instead of a pump contactor.

How Z30-2086-012 differs from the sibling boards

Board Difference
Z30-2086-004 240 VAC with 8 A gold flash relay
Z30-2086-011 120 VAC with sealed 5 A relay
Z30-2086-012 240 VAC with sealed 5 A relay (this part)
Z30-2043-012 240 VAC, sealed 5 A relay but phono jacks

Z30-2086-012 and Z30-2043-012 are the same electrical specification; the first uses terminal blocks and the second uses phono jacks for the transducer. A switch that has phono jacks cannot take the terminal-block board because the transducer plug does not fit.

Selection checks for Z30-2086-012

  • Mains supply must be 240 VAC.
  • Relay must be sealed, not gold flash.
  • Transducer wiring must go to terminal blocks.
  • If in doubt, send the original board number or nameplate photo.

Installation and commissioning of Z30-2086-012

Switch off the mains and verify absence of voltage. Replace the board, reconnect TB4 and TB5, and select the fail-safe jumper. The manual notes that the relay wiring should stay within the relay capacity and that the conduit seal-drain fitting should be installed where it is required by the area classification.

Maintenance of Z30-2086-012

If the replaced board came from a unit that had contact trouble, look for moisture or condensate in the housing. Replace the O-ring 012-2101-345 when it is worn, tighten the cover completely, and keep the conduit entries sealed.

Record the board number against the tag and add the failed board to the lessons-learned list. Because the relay is sealed and the supply is mains, the replacement is a planned outage item rather than a live job, and the electrician should lock out the feeder before the cover is opened, as the manual warns for explosion-hazard installations.

Mechanical data of the Model 910 that carries Z30-2086-012

Dimension Value
Housing diameter 4.63 inch (117 mm)
Housing section dimensions on the drawing 6.25 inch (158 mm) and 4.48 inch (113 mm)
Rotation clearance 3.44 inch (87 mm)
Overhead clearance for the cover 2.75 inch (70 mm)
Transducer diameter 0.875 inch (22 mm)
Tank connection 3/4 inch NPT, or 1 inch BSP version

Approvals and conditions of use that apply to Z30-2086-012

Manual 51-604 states the approvals of the complete Model 910. They matter for a board replacement because the certified configuration must be restored.

Item Statement
FM/FMc explosion proof FM19US0170X / FM20CA0034X, Class I Div 1 Groups B, C, D T6; Class II, III Div 1 Groups E, F, G T6; Type 4X
Non-incendive Class I Div 2 Groups A, B, C, D T5; Class II, III Div 2 Groups F and G T5
ATEX flameproof FM20ATEX0005X, II 2 G Ex db IIC T6 Gb, IP66
IECEx FMG20.0004X, Ex db IIC T6 Gb, IP66
Ambient limit -40 to +70 C; probes longer than 60 inches -20 to +70 C
Use Only with the Echotel 910 probe; keep enclosure temperature at or below 70 C to hold the T6 code

Additional characteristics of the Model 910 that the board serves are below.

Characteristic Value
Sensing principle Ultrasonic across a transducer gap, 3 MHz
Transducer tip 316 stainless steel with epoxy-encapsulated crystals
Power consumption 2.5 VA nominal
Repeatability 0.078 inch (2 mm)
Process (transducer) -40 to +250 F (-40 to +121 C)
Operating pressure 800 psig (55 bar)

Documents and quotation

The manufacturer manual 51-604 for the Echotel Model 910 is attached as the datasheet for Z30-2086-012, so the parts table, relay wiring table and specifications can be checked directly. To get a quotation, send an RFQ with part number Z30-2086-012, the quantity, the supply voltage and relay type printed on the Model 910 nameplate and the delivery location in Oman or the GCC. Quote the supply voltage and relay type with the part number, because the Model 910 boards differ in exactly those two characteristics.

Spares and Lifecycle Considerations

For critical service, many plants hold one Magnetrol Z30-2086-012 as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical level switches units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.

Other Models in the Magnetrol 910 Range

Seven Star LLC supplies models from the Magnetrol 910 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Magnetrol Z30-2086-003 Echotel 910 Relay PC Board 120 VAC 8A DPDTLevel SwitchesView details
Magnetrol Z30-2043-003 Echotel 910 Phono Jack PC Board, 120 VACLevel SwitchesView details
Magnetrol Z30-2086-002 Echotel 910 PC Board 24 VDC 8A DPDTLevel SwitchesView details
Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC 5A Sealed RelayLevel SwitchesView details
Magnetrol Z30-2086-012 Echotel 910 PC Board 240 VAC 5A Sealed RelayLevel SwitchesYou are viewing this model
Magnetrol Z30-2043-002 Echotel 910 Phono Jack PC Board 24 VDCLevel SwitchesView details
Magnetrol Z30-2086-004 Echotel 910 PC Board 240 VAC 8A DPDTLevel SwitchesView details
Datasheets & Documents
  • PDF Datasheet Magnetrol Z30-2086-012 Echotel 910 PC Board 240 VAC 5A Sealed Relay Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol Z30-2086-012 Echotel 910 PC Board 240 VAC

Answers from our engineering team on installation, compatibility and integration.

01What is Magnetrol Z30-2086-012?
It is the 240 VAC PC board with a hermetically sealed 5 A DPDT relay and terminal blocks for the Echotel Model 910.
02What is the phono jack equivalent of Z30-2086-012?
Z30-2043-012 is listed as the 240 VAC board with a 5 A hermetically sealed relay and phono jacks.
03What tolerance applies to the mains supply?
The manual gives 240 VAC plus 10 percent and minus 15 percent, at 50 or 60 Hz.
04What is the pressure rating of the Model 910?
The operating pressure is 800 psig (55 bar) and the mechanical design pressure is 1500 psig (103 bar).
05Can Seven Star LLC quote Z30-2086-012?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.