- Automation & ControlView all 3,043 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Magnetrol
Magnetrol Z30-2086-004 Echotel 910 PC Board 240 VAC 8A DPDT
Description
Magnetrol Z30-2086-004 and the 240 VAC Echotel 910
Oman and the wider GCC distribute single-phase power at 240 V, so the mains-powered Echotel 910 variants that matter locally are the 240 VAC ones. Magnetrol Z30-2086-004 is the printed circuit board for that voltage with the 8 A DPDT output relay and the TB4 and TB5 terminal blocks. It is listed in manual 51-604 as part of item 1.
Stocking the 240 VAC board next to the 24 VDC one is the usual practice in a plant with mixed panels. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What Z30-2086-004 provides
- Mains supply 240 VAC, tolerance plus 10 percent and minus 15 percent, at 50 or 60 Hz.
- Nominal power consumption 2.5 VA.
- Gold flash DPDT relay with 8 A at 240 VAC.
- Terminal blocks TB4 and TB5 take the transducer wires; no soldering and no phono jack.
- Field selectable fail-safe, no calibration.
Specification table for Z30-2086-004
| Parameter | Value |
|---|---|
| Part number | Z30-2086-004 |
| Supply | 240 VAC +10/-15 percent, 50/60 Hz |
| Output relay | 8 A DPDT, gold flash |
| Sensing principle | Ultrasonic across a transducer gap, 3 MHz |
| Power consumption | 2.5 VA nominal |
| Fail-safe | Field selectable high or low |
| Ambient (electronics) | -40 to +158 F (-40 to +70 C) |
| Mechanical design pressure | 1500 psig (103 bar) |
| Housing | Aluminum sand cast, dual 3/4 inch NPT conduit entries |
Applications of Z30-2086-004 in oil and gas, utilities, water and manufacturing
A mains-powered level switch is convenient at remote sumps and pump houses where only a single-phase supply is run. Typical places are wellhead drain tanks, fuel day tanks for emergency generators, stormwater sumps, sewage lift stations and cooling tower basin make-up. The relay can switch a contactor coil directly within its 8 A rating.
Because the board has no adjustment, a failure is cured only by replacement. That is why a plant with many switches keeps a board spare rather than a whole instrument.
How Z30-2086-004 differs from the other 910 boards
| Board | Variant |
|---|---|
| Z30-2086-003 | 120 VAC, 8 A, terminal blocks |
| Z30-2086-004 | 240 VAC, 8 A, terminal blocks (this part) |
| Z30-2086-012 | 240 VAC, 5 A hermetically sealed, terminal blocks |
| Z30-2043-004 | 240 VAC, 8 A, phono jacks |
The 240 VAC board and the 120 VAC board look alike, and putting 240 V on the 120 VAC board is the typical error to avoid. The part number letters and digits are the only safe distinction, together with the voltage printed on the nameplate of the switch.
Selection checks for Z30-2086-004
- Mains voltage on the nameplate of the switch is 240 VAC.
- Relay type: 8 A gold flash, not the hermetically sealed 5 A type.
- Terminal blocks TB4 and TB5 rather than phono jacks.
- Hazardous area suitability may be impaired by substituting components, according to the manual warning.
Installation notes for Z30-2086-004
Isolate the mains before opening the cover. In hazardous areas, the manual cautions that the conduit seal must be in place and that the unit must not be powered until it is complete. Land the mains on the power terminals, the relay on its terminals, and choose the P1 jumper position for the desired action on power loss or on dry gap.
Service and maintenance
Mains boards deserve one extra check: after the replacement, measure the supply on the terminals with the cover off only when the area is declared safe, and confirm that the relay contacts switch an 8 A load without chatter. The manual lists the 240 VAC relay rating as 8 A, and a heavier contactor coil should be isolated through an interposing relay.
Do not attempt repair of the explosion-proof enclosure flamepath. Check the 3 MHz transducer gap for crystallised product or foam, which stops the signal and keeps the relay in the dry state.
Mechanical data of the Model 910 that carries Z30-2086-004
| Dimension | Value |
|---|---|
| Cover swing and rotation space | 87 mm (3.44 inch) around the housing, plus 70 mm (2.75 inch) above it |
| Cast housing outer diameter | 117 mm, equal to 4.63 inch |
| Probe diameter | 22 mm (0.875 inch) |
| Process thread choices | NPT 3/4 inch or BSP 1 inch |
| Mounting flange | An optional flange is drawn in the manual, with a 3.50 inch (88 mm) dimension |
Approvals and conditions of use that apply to Z30-2086-004
Manual 51-604 states the approvals of the complete Model 910. They matter for a board replacement because the certified configuration must be restored.
| Item | Statement |
|---|---|
| Flameproof in Europe | ATEX certificate FM20ATEX0005X with marking II 2 G Ex db IIC T6 Gb and IP66 |
| International scheme | IECEx FMG20.0004X, Ex db IIC T6 Gb |
| North America explosion proof | Class I Div 1 B, C, D at T6 and Class II/III Div 1 E, F, G at T6 (FM19US0170X, FM20CA0034X), Type 4X |
| Div 2 option | Non-incendive: Class I Div 2 A to D, T5, and Class II/III Div 2 F and G, T5 |
| Special condition | Do not repair flamepaths; limit static discharge; hold the enclosure at or below 70 C |
| Ambient range | Minus 40 up to plus 70 C (probes beyond 60 inches: minus 20 C minimum) |
Additional characteristics of the Model 910 that the board serves are below.
| Characteristic | Value |
|---|---|
| Power supply options | 120 VAC or 240 VAC (+10/-15 percent), 50/60 Hz; 24 VDC (plus or minus 10 percent) |
| Power consumption | 2.5 VA nominal |
| Fail-safe | Field selectable high or low |
| Calibration | None required; set point not adjustable |
| Ambient (electronics) | -40 to +158 F (-40 to +70 C) |
| Mechanical design pressure | 1500 psig (103 bar) |
| Shock / vibration | ANSI/ISA-S71.03 Class SA1 / VC2 |
Documents and quotation
The manufacturer manual 51-604 for the Echotel Model 910 is attached as the datasheet for Z30-2086-004, so the parts table, relay wiring table and specifications can be checked directly. To get a quotation, send an RFQ with part number Z30-2086-004, the quantity, the supply voltage and relay type printed on the Model 910 nameplate and the delivery location in Oman or the GCC. Quote the supply voltage and relay type with the part number, because the Model 910 boards differ in exactly those two characteristics.
Other Models in the Magnetrol 910 Range
Seven Star LLC supplies models from the Magnetrol 910 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol Z30-2086-003 Echotel 910 Relay PC Board 120 VAC 8A DPDT | Level Switches | View details |
| Magnetrol Z30-2043-003 Echotel 910 Phono Jack PC Board, 120 VAC | Level Switches | View details |
| Magnetrol Z30-2086-002 Echotel 910 PC Board 24 VDC 8A DPDT | Level Switches | View details |
| Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC 5A Sealed Relay | Level Switches | View details |
| Magnetrol Z30-2086-012 Echotel 910 PC Board 240 VAC 5A Sealed Relay | Level Switches | View details |
| Magnetrol Z30-2043-002 Echotel 910 Phono Jack PC Board 24 VDC | Level Switches | View details |
| Magnetrol Z30-2086-004 Echotel 910 PC Board 240 VAC 8A DPDT | Level Switches | You are viewing this model |
Datasheets & Documents
- Datasheet Magnetrol Z30-2086-004 Echotel 910 PC Board 240 VAC 8A DPDT Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Z30-2086-004 Echotel 910 PC Board 240 VAC
Answers from our engineering team on installation, compatibility and integration.
01What is Magnetrol Z30-2086-004?
It is the 240 VAC, 8 A DPDT relay PC board with TB4 and TB5 terminal blocks for the Echotel Model 910, listed in manual 51-604.
02What power does the Model 910 use?
The manual lists 120 VAC or 240 VAC (+10/-15 percent), 50/60 Hz, or 24 VDC (plus or minus 10 percent), with 2.5 VA consumption.
03What is the process temperature limit?
The transducer is rated for -40 to +250 F (-40 to +121 C), with operating pressure of 800 psig (55 bar).
04Which is the phono jack equivalent?
Z30-2043-004 is the 240 VAC board with an 8 A relay and phono jacks.
05Can Seven Star LLC quote Z30-2086-004?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.


















Reviews
There are no reviews yet.