Magnetrol Z30-2043-002 Echotel 910 Phono Jack PC Board 24 VDC
Description
Magnetrol Z30-2043-002: phono-jack board for the Echotel 910 at 24 VDC
Phono jacks are not what one expects on an industrial level switch, but the Echotel Model 910 was built with two connection styles, and Magnetrol Z30-2043-002 is the 24 VDC board with an 8 A relay for the phono-jack style. The transducer wires land on jacks J1 and J2 instead of terminal blocks TB4 and TB5.
The manual includes a note that matters to buyers: transducers with phono plug connections to the PC board require the entire Model 910 to be replaced. In other words a phono-jack board is paired with the original transducer of that design. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Identification of Z30-2043-002
- Connection: jacks J1 and J2, the Z30-2043 series.
- Supply: 24 VDC.
- Relay: 8 A, as in the manual row “24 VDC with 8 amp relay”.
- Item 1, with the other phono boards Z30-2043-003 (120 VAC) and Z30-2043-004 (240 VAC).
Technical table for Z30-2043-002
| Parameter | Value |
|---|---|
| Part number | Z30-2043-002 |
| Connection style | Phono jacks J1 and J2 |
| Supply | 24 VDC |
| Relay | 8 A DPDT |
| Sensing principle | Ultrasonic across a transducer gap, 3 MHz |
| Power supply options | 120 VAC or 240 VAC (+10/-15 percent), 50/60 Hz; 24 VDC (plus or minus 10 percent) |
| Fail-safe | Field selectable high or low |
| Process (transducer) | -40 to +250 F (-40 to +121 C) |
| Mechanical design pressure | 1500 psig (103 bar) |
| Housing | Aluminum sand cast, dual 3/4 inch NPT conduit entries |
Where Z30-2043-002 is found in oil and gas, utilities, water and manufacturing
Phono-jack boards belong to installed Model 910 switches that may have run for years in refineries, fertiliser plants and municipal pump stations, and a failed board there is a repair, not a new project. Replacing the board is cheaper than replacing the full instrument and brings a switch back without re-engineering the process connection.
A 24 VDC supply is the easiest to integrate with panel power in these older plants, which commonly have a 24 V DC distribution for instrumentation.
How Z30-2043-002 differs from nearby boards
| Board | Difference |
|---|---|
| Z30-2043-002 | Phono jacks, 24 VDC, 8 A relay (this part) |
| Z30-2043-010 | Phono jacks, 24 VDC, 5 A HS relay |
| Z30-2086-002 | Terminal blocks, 24 VDC, 8 A relay |
| Z30-2043-003 | Phono jacks, 120 VAC, 8 A relay |
The manual calls the other phono relay type “5 amp HS”, which is the sealed type in the specification; Z30-2043-002 is the 8 A variant. Compared with Z30-2086-002 the electrical specification matches, but the transducer connection differs, so the boards are not interchangeable.
Selection checks for Z30-2043-002
- The old board has two phono jacks marked J1 and J2.
- Supply is 24 VDC.
- Relay is the 8 A type.
- Send a photo of the old board with the request if there is any doubt.
Installation notes for Z30-2043-002
Open the housing, unplug the transducer phono plugs, replace the board, and plug the transducer back into J1 and J2. Select the fail-safe jumper and connect the relay wiring. Test by wetting the gap.
Maintenance of Z30-2043-002
Plug contacts can oxidize in humid air. Inspect them and the O-ring 012-2101-345 at each service visit, and keep the housing cover tight.
When a phono-jack board is no longer available in a given variant, the manual route is replacement of the whole Model 910 rather than a conversion to terminal blocks, so planning the spare early is wiser than waiting for a failure. Keep the transducer plugs clean and seat them fully so that the J1 and J2 contacts do not form a noisy connection that makes the relay chatter. The manual lists chatter as a symptom to check against voltage, turbulence and aeration.
Mechanical data of the Model 910 that carries Z30-2043-002
| Dimension | Value |
|---|---|
| Cover swing and rotation space | 87 mm (3.44 inch) around the housing, plus 70 mm (2.75 inch) above it |
| Cast housing outer diameter | 117 mm, equal to 4.63 inch |
| Probe diameter | 22 mm (0.875 inch) |
| Process thread choices | NPT 3/4 inch or BSP 1 inch |
| Mounting flange | An optional flange is drawn in the manual, with a 3.50 inch (88 mm) dimension |
Approvals and conditions of use that apply to Z30-2043-002
Manual 51-604 states the approvals of the complete Model 910. They matter for a board replacement because the certified configuration must be restored.
| Item | Statement |
|---|---|
| Flameproof in Europe | ATEX certificate FM20ATEX0005X with marking II 2 G Ex db IIC T6 Gb and IP66 |
| International scheme | IECEx FMG20.0004X, Ex db IIC T6 Gb |
| North America explosion proof | Class I Div 1 B, C, D at T6 and Class II/III Div 1 E, F, G at T6 (FM19US0170X, FM20CA0034X), Type 4X |
| Div 2 option | Non-incendive: Class I Div 2 A to D, T5, and Class II/III Div 2 F and G, T5 |
| Special condition | Do not repair flamepaths; limit static discharge; hold the enclosure at or below 70 C |
| Ambient range | Minus 40 up to plus 70 C (probes beyond 60 inches: minus 20 C minimum) |
Additional characteristics of the Model 910 that the board serves are below.
| Characteristic | Value |
|---|---|
| Power supply options | 120 VAC or 240 VAC (+10/-15 percent), 50/60 Hz; 24 VDC (plus or minus 10 percent) |
| Power consumption | 2.5 VA nominal |
| Fail-safe | Field selectable high or low |
| Calibration | None required; set point not adjustable |
| Ambient (electronics) | -40 to +158 F (-40 to +70 C) |
| Mechanical design pressure | 1500 psig (103 bar) |
| Shock / vibration | ANSI/ISA-S71.03 Class SA1 / VC2 |
Documents and quotation
The manufacturer manual 51-604 for the Echotel Model 910 is attached as the datasheet for Z30-2043-002, so the parts table, relay wiring table and specifications can be checked directly. To get a quotation, send an RFQ with part number Z30-2043-002, the quantity, the supply voltage and relay type printed on the Model 910 nameplate and the delivery location in Oman or the GCC. Quote the supply voltage and relay type with the part number, because the Model 910 boards differ in exactly those two characteristics.
Other Models in the Magnetrol 910 Range
Seven Star LLC supplies models from the Magnetrol 910 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol Z30-2086-003 Echotel 910 Relay PC Board 120 VAC 8A DPDT | Level Switches | View details |
| Magnetrol Z30-2043-003 Echotel 910 Phono Jack PC Board, 120 VAC | Level Switches | View details |
| Magnetrol Z30-2086-002 Echotel 910 PC Board 24 VDC 8A DPDT | Level Switches | View details |
| Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC 5A Sealed Relay | Level Switches | View details |
| Magnetrol Z30-2086-012 Echotel 910 PC Board 240 VAC 5A Sealed Relay | Level Switches | View details |
| Magnetrol Z30-2043-002 Echotel 910 Phono Jack PC Board 24 VDC | Level Switches | You are viewing this model |
| Magnetrol Z30-2086-004 Echotel 910 PC Board 240 VAC 8A DPDT | Level Switches | View details |
Datasheets & Documents
- Datasheet Magnetrol Z30-2043-002 Echotel 910 Phono Jack PC Board 24 VDC Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Z30-2043-002 Echotel 910 Phono Jack PC
Answers from our engineering team on installation, compatibility and integration.
01What is Magnetrol Z30-2043-002?
It is the 24 VDC phono-jack PC board with an 8 A relay for the Echotel Model 910.
02Where do the transducer wires connect?
On this board they connect to phono jacks J1 and J2, whereas the Z30-2086 series uses terminal blocks TB4 and TB5.
03Can I replace only the transducer on a phono-jack unit?
The manual notes that transducers with phono plug connections to the PC board require the entire Model 910 to be replaced.
04Which other phono boards exist?
The manual lists Z30-2043-003 (120 VAC, 8 A), Z30-2043-004 (240 VAC, 8 A), Z30-2043-010, -011 and -012 with 5 A HS relays.
05Can Seven Star LLC quote Z30-2043-002?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.